Detection of Drugs in Simultaneously Collected Samples of Oral Fluid and Blood
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Simultaneously collected samples of oral fluid and blood in a naturalistic setting could provide a qualitative impression of the relative detection times of drugs in oral fluid compared to blood. The aim of this study was to compare detections of different drugs in oral fluid and blood from a large material of paired samples. The study included results from 930 paired oral fluid and blood samples collected from drivers suspected for driving under the influence of drugs. Oral fluid was collected using the Intercept device. Blood samples were screened using an ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS-MS) method and positive results were confirmed and quantified with a different analytical method. Oral fluid samples were analyzed using UHPLC-MS-MS. The drugs included in the study were: amphetamine, methamphetamine, tetrahydrocannabinol (THC), diazepam, N-desmethyldiazepam, clonazepam, alprazolam, nitrazepam, oxazepam, morphine, 6-monoacetylmorphine (6-MAM), methadone and buprenorphine. The drugs detected more frequently in oral fluid compared to blood were amphetamine (497 positive in oral fluid/408 positive in blood), methamphetamine (332/232), oxazepam (106/36), morphine (65/31) and 6-MAM (19/0). The drugs detected less frequently in oral fluid compared to blood were THC (224 positive in oral fluid/407 positive in blood), diazepam (137/160), N-desmethyldiazepam (183/188), clonazepam (148/307), alprazolam (47/68), nitrazepam (16/29) and buprenorphine (31/59). For methadone, the number of detections was the same in oral fluid and in blood (23/23). The results indicate that for amphetamine, methamphetamine, morphine and 6-MAM, relative detection time is longer in oral fluid than in blood, while for benzodiazepines, the results indicate that relative detection time is shorter in oral fluid than in blood. For oxazepam and buprenorphine, the results were dependent on the cut-off limits used. Regarding THC, the detection time in oral fluid depends on the sampling method. The relative detection time was shorter than in blood when using the Intercept device.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Research shows a good correlation between drug detection in oral fluid and other matrices; however, oral fluid concentrations cannot predict blood concentrations or vice versa (10, 18, 19).”
From Recommendations for Toxicological Investigation of Drug-Impaired Driving and Motor Vehicle Fatalities—2021 Update (2021) · cites this paper as [19]
In the citing paper
“however, oral fluid concentrations cannot predict blood concentrations or vice versa (10, 18, 19).”
From Recommendations for Toxicological Investigation of Drug-Impaired Driving and Motor Vehicle Fatalities—2021 Update (2021) · cites this paper as [19]
Citations
Cites
Review: The physiology of saliva and transfer of drugs into saliva
Aps, J. K. M., & Martens, L. C. (2005) · Forensic Science International · doi:10.1016/j.forsciint.2004.10.026 · Cited by 560
Detection times of drugs of abuse in blood, urine, and oral fluid
Verstraete, A. G. (2004) · Therapeutic Drug Monitoring · doi:10.1097/00007691-200404000-00020 · Cited by 521
Oral fluid testing for drugs of abuse
Bosker, W. M., & Huestis, M. A. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.108670 · Cited by 378
Alternative Specimens for Workplace Drug Testing*
Caplan, Y. H., & Goldberger, B. A. (2001) · Journal of Analytical Toxicology · doi:10.1093/jat/25.5.396 · Cited by 203
Verstraete, A. G. (2005) · Forensic Science International · doi:10.1016/j.forsciint.2004.11.023 · Cited by 184
Drug Testing in Oral Fluid—Evaluation of Sample Collection Devices
Langel, K., Engblom, C., Pehrsson, A., Gunnar, T., Ariniemi, K., & Lillsunde, P. (2008) · Journal of Analytical Toxicology · doi:10.1093/jat/32.6.393 · Cited by 177
Guidelines for research on drugged driving
Walsh, J. M., Verstraete, A. G., Huestis, M. A., & Mørland, J. (2008) · Addiction · doi:10.1111/j.1360-0443.2008.02277.x · Cited by 171
Drug Screening of Preserved Oral Fluid by Liquid Chromatography–Tandem Mass Spectrometry
Øiestad, E. L., Johansen, U., & Christophersen, A. S. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.074237 · Cited by 167
Review: Pharmacokinetics of illicit drugs in oral fluid
Drummer, O. H. (2005) · Forensic Science International · doi:10.1016/j.forsciint.2004.11.022 · Cited by 163
Berg, T., & Strand, D. H. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.10.081 · Cited by 158
Research works printed but not linked: 1
- Substance Abuse and Mental Health Sevice Administration, 2004, Proposed revisions to mandatory guidelines for federal workplace drug testing programs, Federal Register, 69, 19673
Cited by
D’Orazio, A. L., Mohr, A. L. A., Chan-Hosokawa, A., Harper, C., Huestis, M. A., Limoges, J. F., Miles, A. K., Scarneo, C. E., Kerrigan, S., Liddicoat, L. J., et al. (2021) · Journal of Analytical Toxicology · doi:10.1093/jat/bkab064 · Cited by 60
“Research shows a good correlation between drug detection in oral fluid and other matrices; however, oral fluid concentrations cannot predict blood concentrations or vice versa (10, 18, 19).”
BackgroundWhat the lab can and cannot do: clinical interpretation of drug testing results
Kapur, B. M., & Aleksa, K. (2020) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2020.1774493 · Cited by 41
“Cannabinoids are particularly susceptible to drug adsorption [46,48].”
BackgroundSuperhydrophobic 3D‐Assembled Metallic Nanoparticles for Trace Chemical Enrichment in SERS Sensing
Liu, Y., Zhang, N., Tua, D., Zhu, Y., Rada, J., Yang, W., Song, H., Thompson, A. C., Collins, R. L., & Gan, Q. (2022) · Small · doi:10.1002/smll.202204234 · Cited by 39
Robertson, M. B., Li, A., Yuan, Y., Jiang, A., Gjerde, H., Staples, J. A., & Brubacher, J. R. (2022) · Accident Analysis & Prevention · doi:10.1016/j.aap.2022.106694 · Cited by 21
Self-citationWang, J., Yao, W., Meng, F., Wang, P., Wu, Y., & Wang, B. (2019) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.22993 · Cited by 21
Metadata
- Authors
- Bakke, E., Høiseth, G., Arnestad, M., & Gjerde, H.
- Affiliations
- Oslo University Hospital (NO)
- Corresponding author
- Bakke, Eirin
- Venue
- Journal of Analytical Toxicology
- Publisher
- Oxford University Press (OUP)
- Published
- 2018-10-06
- Volume
- 43
- Issue
- 3
- Pages
- 228-232
- ISSN
- 0146-4760 (ISSN-L)
- 1945-2403
- OpenAlex
- W2895771152
- Cited by
- 25
- References
- 35
- Citations by year
- 2026: 2 · 2025: 2 · 2023: 5 · 2022: 7 · 2021: 5 · 2020: 3 · 2019: 1
- FWCI
- 1.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model (vor)
- Locations
- Journal of Analytical Toxicology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Forensic Toxicology and Drug Analysis
- Health Sciences › Medicine › Epidemiology › Substance Abuse Treatment and Outcomes
- Social Sciences › Sociology and Political Science › Doping in Sports
- Keywords
- oral fluid drug testing, blood drug testing, amphetamine, methamphetamine, tetrahydrocannabinol, benzodiazepines, morphine, 6-monoacetylmorphine, methadone, buprenorphine, driving under the influence, cut-off values, naturalistic settings
- MeSH terms
- Driving Under the Influence, Chromatography, High Pressure Liquid, Humans, Saliva, Sensitivity and Specificity, Illicit Drugs, Substance Abuse Detection, Tandem Mass Spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Drugs in Simultaneously Collected Samples of Oral Fluid and Blood. https://app.cochat.ai/papers/10.1093/jat/bky079
- The paper
- Bakke, E., Høiseth, G., Arnestad, M., & Gjerde, H. (2019). Detection of Drugs in Simultaneously Collected Samples of Oral Fluid and Blood. Journal of Analytical Toxicology. https://doi.org/10.1093/jat/bky079
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.