The DOI matches its Crossref record.
Phase measurement of atomic resolution image using transport of intensity equation
Abstract
Since the Transport Intensity Equation (TIE) has been applied to electron microscopy only recently, there are controversial discussions in the literature regarding the theoretical concepts underlying the equation and the practical techniques to solve the equation. In this report we explored some of the issues regarding the TIE, especially bearing electron microscopy in mind, and clarified that: (i) the TIE for electrons exactly corresponds to the Schrödinger equation for high-energy electrons in free space, and thus the TIE does not assume weak scattering; (ii) the TIE can give phase information at any distance from the specimen, not limited to a new field; (iii) information transfer in the TIE for each spatial frequency g will be multiplied by g2 and thus low frequency components will be dumped more with respect to high frequency components; (vi) the intensity derivative with respect to the direction of wave propagation is well approximated by using a set of three symmetric images; and (v) a substantially larger defocus distance than expected before can be used for high-resolution electron microscopy. In the second part of this report we applied the TIE down to atomic resolution images to obtain phase information and verified the following points experimentally: (i) although low frequency components are attenuated in the TIE, all frequencies will be recovered satisfactorily except the very low frequencies; and (ii) using a reconstructed phase and the measured image intensity we can correct effectively the defects of imaging, such as spherical aberrations as well as partial coherence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Skyrmion flow near room temperature in an ultralow current density
Yu, X. Z., Kanazawa, N., Zhang, W. Z., Nagai, T., Hara, T., Kimoto, K., Matsui, Y., Onose, Y., & Tokura, Y. (2012) · Nature Communications · doi:10.1038/ncomms1990 · Cited by 892
Tokura, Y., & Kanazawa, N. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00297 · Cited by 726
Transformation between meron and skyrmion topological spin textures in a chiral magnet
Yu, X. Z., Koshibae, W., Tokunaga, Y., Shibata, K., Taguchi, Y., Nagaosa, N., & Tokura, Y. (2018) · Nature · doi:10.1038/s41586-018-0745-3 · Cited by 448
Magnetic stripes and skyrmions with helicity reversals
Yu, X., Mostovoy, M., Tokunaga, Y., Zhang, W., Kimoto, K., Matsui, Y., Kaneko, Y., Nagaosa, N., & Tokura, Y. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1118496109 · Cited by 354
Multiaxial magnetocrystalline anisotropy in the X -type hexaferrite Sr2Co2Fe28O46 at low temperature
Komabuchi, M., Urushihara, D., Kimata, Y., Okabe, M., Asaka, T., & Fukuda, K. (2019) · Physical Review B · doi:10.1103/physrevb.100.094406 · Cited by 10
Metadata
- Authors
- Ishizuka, K., & Allman, B.
- Venue
- Microscopy
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-06-01
- Volume
- 54
- Issue
- 3
- Pages
- 191-197
- ISSN
- 2050-5698 (ISSN-L)
- 2050-5701
- OpenAlex
- W2077652406
- Cited by
- 217
- References
- 0
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Phase measurement of atomic resolution image using transport of intensity equation. https://app.cochat.ai/papers/10.1093/jmicro/dfi024
- The paper
- Ishizuka, K., & Allman, B. (2005). Phase measurement of atomic resolution image using transport of intensity equation. Microscopy. https://doi.org/10.1093/jmicro/dfi024
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.