Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 243

The DOI matches its Crossref record.

Effect of Estrogen Replacement Therapy on the Specificity and Sensitivity of Screening Mammography

Laya, M. B., Larson, E. B., Taplin, S. H., White, E.·1996·JNCI Journal of the National Cancer Institute

Abstract

BACKGROUND: Previous studies have demonstrated that mammographic breast density increases following the initiation of estrogen replacement therapy (ERT). The effect, if any, that this increase in density has on the specificity (related to false-positive readings) and the sensitivity (related to false-negative readings) of screening mammography is unknown. PURPOSE: Using a retrospective cohort study design, we assessed the effects of ERT on the specificity and the sensitivity of screening mammography. METHODS: Participants (n = 8779) were postmenopausal women, aged 50 years or older, who were enrolled in a health maintenance organization located in western Washington state and who entered a breast cancer screening program between January 1988 and June 1993. Two-view mammography was performed as part of a comprehensive breast cancer screening visit. Menopausal status, as well as demographic and risk-factor information, was recorded via self-administered questionnaires. Hormonal replacement therapy type and use were determined from questionnaire data and from an automated review of pharmacy records. Individuals diagnosed with breast cancer within 12 months of their first screening-program mammograms were identified through use of a regional cancer registry. Risk ratios (RRs) plus 95% confidence intervals (CIs) of false-positive as well as false-negative examinations among current and former ERT users (with never users as the reference group) were calculated. Reported P values are two-sided. RESULTS: The specificity of mammographic screening was lower for current users of ERT than for never users or former users. Defining a positive mammographic reading as any non-normal reading (either suspicious for cancer or indeterminate), the adjusted RR (95% CI) of a false-positive reading for current users versus never users was 1.33 (1.15-1.54) (P < .001); for former users versus never users, the RR (95% CI) was 1.00 (0.87-1.15). The adjusted mammographic specificities (95% CIs) for never users, former users, and current users of ERT were 86% (84%-88%), 86% (84%-87%), and 82% (80%-84%), respectively. Defining a positive reading more rigorously (i.e., as suspicious for cancer only), the adjusted RRs (95% CIs) of false-positive readings for current users and former users (versus never users) were 1.71 (1.37-2.14) (P < .001) and 1.16 (0.93-1.45), respectively. Sensitivity was also lower in women currently receiving ERT. The unadjusted RR (95% CI) of a false-negative reading for current users versus never users was 5.23 (1.09-25.02) (P = .04); for former users versus never users, the RR (95% CI) was 1.06 (0.10-10.87). The unadjusted mammographic sensitivities (95% CI) for never users, former users, and current users of ERT were 94% (80%-99%), 94% (69%-99%), and 69% (38%-91%), respectively. CONCLUSIONS AND IMPLICATIONS: Current use of ERT is associated with lower specificity and lower sensitivity of screening mammography. Lower specificity could increase the cost of breast cancer screening, and lower sensitivity may decrease its effectiveness.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/jnci/88.10.643

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 243

Metadata

Authors
Laya, M. B., Larson, E. B., Taplin, S. H., & White, E.
Venue
JNCI Journal of the National Cancer Institute
Published
1996-05-15
Volume
88
Issue
10
Pages
643-649
ISSN
  • 0027-8874 (ISSN-L)
  • 1460-2105
OpenAlex
W1995244346
Cited by
243
References
0
FWCI
17.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of Estrogen Replacement Therapy on the Specificity and Sensitivity of Screening Mammography. https://app.cochat.ai/papers/10.1093/jnci/88.10.643
The paper
Laya, M. B., Larson, E. B., Taplin, S. H., & White, E. (1996). Effect of Estrogen Replacement Therapy on the Specificity and Sensitivity of Screening Mammography. JNCI Journal of the National Cancer Institute. https://doi.org/10.1093/jnci/88.10.643

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.