Mammography Facility Characteristics Associated With Interpretive Accuracy of Screening Mammography
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND: Although interpretive performance varies substantially among radiologists, such variation has not been examined among mammography facilities. Understanding sources of facility variation could become a foundation for improving interpretive performance. METHODS: In this cross-sectional study conducted between 1996 and 2002, we surveyed 53 facilities to evaluate associations between facility structure, interpretive process characteristics, and interpretive performance of screening mammography (ie, sensitivity, specificity, positive predictive value [PPV1], and the likelihood of cancer among women who were referred for biopsy [PPV2]). Measures of interpretive performance were ascertained prospectively from mammography interpretations and cancer data collected by the Breast Cancer Surveillance Consortium. Logistic regression and receiver operating characteristic (ROC) curve analyses estimated the association between facility characteristics and mammography interpretive performance or accuracy (area under the ROC curve [AUC]). All P values were two-sided. RESULTS: Of the 53 eligible facilities, data on 44 could be analyzed. These 44 facilities accounted for 484 463 screening mammograms performed on 237 669 women, of whom 2686 were diagnosed with breast cancer during follow-up. Among the 44 facilities, mean sensitivity was 79.6% (95% confidence interval [CI] = 74.3% to 84.9%), mean specificity was 90.2% (95% CI = 88.3% to 92.0%), mean PPV1 was 4.1% (95% CI = 3.5% to 4.7%), and mean PPV2 was 38.8% (95% CI = 32.6% to 45.0%). The facilities varied statistically significantly in specificity (P < .001), PPV1 (P < .001), and PPV2 (P = .002) but not in sensitivity (P = .99). AUC was higher among facilities that offered screening mammograms alone vs those that offered screening and diagnostic mammograms (0.943 vs 0.911, P = .006), had a breast imaging specialist interpreting mammograms vs not (0.932 vs 0.905, P = .004), did not perform double reading vs independent double reading vs consensus double reading (0.925 vs 0.915 vs 0.887, P = .034), or conducted audit reviews two or more times per year vs annually vs at an unknown frequency (0.929 vs 0.904 vs 0.900, P = .018). CONCLUSION: Mammography interpretive performance varies statistically significantly by facility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Circulating microRNAs as Novel Minimally Invasive Biomarkers for Breast Cancer
Heneghan, H. M., Miller, N., Lowery, A. J., Sweeney, K. J., Newell, J., & Kerin, M. J. (2010) · Annals of Surgery · doi:10.1097/sla.0b013e3181cc939f · Cited by 687
Circulating MicroRNAs: a novel class of biomarkers to diagnose and monitor human cancers
Zen, K., & Zhang, C. (2012) · Medicinal Research Reviews · doi:10.1002/med.20215 · Cited by 502
A Pilot Study of Circulating miRNAs as Potential Biomarkers of Early Stage Breast Cancer
Zhao, H., Shen, J., Medico, L., Wang, D., Ambrosone, C. B., & Liu, S. (2010) · PLoS ONE · doi:10.1371/journal.pone.0013735 · Cited by 398
Serum microRNAs as powerful cancer biomarkers
Wittmann, J., & Jäck, H.-M. (2010) · Biochimica et Biophysica Acta (BBA) - Reviews on Cancer · doi:10.1016/j.bbcan.2010.07.002 · Cited by 257
Kodahl, A. R., Lyng, M. B., Binder, H., Cold, S., Gravgaard, K., Knoop, A. S., & Ditzel, H. J. (2014) · Molecular Oncology · doi:10.1016/j.molonc.2014.03.002 · Cited by 189
Metadata
- Authors
- Taplin, S., Abraham, L., Barlow, W. E., Fenton, J. J., Berns, E. A., Carney, P. A., Cutter, G. R., Sickles, E. A., Carl, D., & Elmore, J. G.
- Venue
- JNCI Journal of the National Cancer Institute
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-06-10
- Volume
- 100
- Issue
- 12
- Pages
- 876-887
- ISSN
- 0027-8874 (ISSN-L)
- 1460-2105
- OpenAlex
- W2171664048
- Cited by
- 89
- References
- 0
- FWCI
- 7.79
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mammography Facility Characteristics Associated With Interpretive Accuracy of Screening Mammography. https://app.cochat.ai/papers/10.1093/jnci/djn172
- The paper
- Taplin, S., Abraham, L., Barlow, W. E., Fenton, J. J., Berns, E. A., Carney, P. A., Cutter, G. R., Sickles, E. A., Carl, D., & Elmore, J. G. (2008). Mammography Facility Characteristics Associated With Interpretive Accuracy of Screening Mammography. JNCI Journal of the National Cancer Institute. https://doi.org/10.1093/jnci/djn172
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.