CoChat

Analysis of Circulating Tumor DNA to Confirm Somatic KRAS Mutations

Holdhoff, Matthias, Schmidt, Kerstin, Donehower, Ross, Diaz, Luis A. · 2009 · JNCI: Journal of the National Cancer Institute
Cited by 92

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

KRAS mutations have clearly emerged as a pharmacogenomic marker that can predict which metastatic colorectal cancers will be resistant to treatment with antibodies that inhibit the epidermal growth factor receptor (EGFR) ( 1 , 2 ). The evaluation of patients for mutations in KRAS is rapidly becoming part of routine practice in clinical oncology and so far has relied mostly on formalin-fixed paraffin-embedded (FFPE) tumor tissue. Accurate KRAS testing is critical because it determines which patients may benefit from anti-EGFR therapy. However, the selection of specimens with a sufficient number of tumor cells, possible genetic heterogeneity between different tumor sites (eg, between primary tumor and metastases), the quality of extracted DNA, and different detection methods for KRAS mutations can interfere with accurate analysis. In addition, formalin fixation often indiscriminately and irreversibly damages DNA, increasing sample-to-sample variability and decreasing the amount of DNA available for molecular analysis. A recent article by Tol et al. ( 3 ), on the effects of KRAS mutations on first-line therapy of colorectal cancer patients with anti-EGFR therapies, highlights this issue. Eight patients had to be excluded from the study because of the discordance in the mutation status of KRAS as assessed by two independent sequencing methods, both performed on FFPE sections of tumor tissue. As an additional example, we would like to report the case of a 58-year-old man with metastatic colorectal cancer whose tumor was being evaluated for mutations in KRAS . Inadvertently, testing was performed by two independent laboratories and revealed two different results. In both laboratories, tissue sections were reviewed by a pathologist, DNA was purified from the malignant areas of microdissected tumor specimens, a region of exon 2 from the KRAS [GenBank accession No. NM_004985.3] gene was amplified by polymerase chain reaction (PCR) and analyzed for the presence of mutations at codons 12 and 13. The first laboratory reported the presence of only wild-type KRAS by melting curve analysis. The second laboratory detected a 35G>T mutation, which causes a glycine to valine substitution at codon 12 of KRAS (G12V), using single-nucleotide primer extension analysis. To resolve these discordant findings, we tested DNA from this patient's plasma for KRAS mutations using a highly sensitive technique termed “BEAMing,” which was named after components of this method (Beads, Emulsification, Amplification, and Magnetics), as previously described ( 4 ). This method uses standard laboratory tools and reagents to create a water-in-oil emulsion wherein each aqueous microdroplet houses an individual fragment of DNA bound to a bead. This setting allows billions of compartmentalized PCRs to be performed in parallel in a single test tube. The products of these reactions coat each bead with thousands of copies of DNA fragments that are identical to the single DNA molecule originally present. In this case, the result is millions of beads coated entirely with either KRAS mutant or KRAS wild-type DNA. To distinguish mutant from wild-type coated beads, allele-specific fluorescent probes complementary to the known wild-type or mutant sequences of KRAS are simultaneously added to the beads for hybridization. The beads are then assessed via flow cytometry to detect rare mutant DNA molecules among a much larger number of normal DNA molecules ( 5 ). BEAMing is a digital assay that is able to count the frequency of individual DNA fragments in a sample, but the sensitivity can be limited by sequence errors introduced by DNA polymerase during PCR. As previously defined in DNA from patients without cancer, the false-positive rate for KRAS mutations ranges between 0.0061% and 0.00023% ( 4 , 6 ). In this case, DNA fragments from 2 mL of plasma, instead of from paraffin-embedded sections, were screened for known mutations in codons 12 and 13 of KRAS . A mutation (35G>T) was detected that matched the reported G12V mutation ( Figure 1 ). The detected mutation represented 0.3% of the DNA from the 2 mL of plasma analyzed, which was substantially higher than the background levels noted above. No other mutations in KRAS had been detected in the patient's sample or in the DNA from patients without cancer. Serial dilutions of tumor DNA that contained the KRAS 35G>T mutation with normal DNA that did not contain the mutation revealed that the mutation could still be detected when it was present only 0.01% as frequently as the wild-type allele ( Supplementary Figure , available online). Flow cytometry histogram from a test of circulating tumor DNA (from plasma) for the presence of a KRAS mutation. DNA was purified from 2 mL of plasma from a patient with metastatic colorectal cancer (A) and from a control subject without cancer (B) and was assessed for the KRAS 35G>T mutation by BEAMing, a technique in which individual DNAs are attached to beads which are subjected to c

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/jnci/djp240

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Holdhoff, M., Schmidt, K., Donehower, R., & Diaz, L. A.
Venue
JNCI: Journal of the National Cancer Institute
Published
2009-09
Volume
101
Issue
18
Pages
1284-1285
ISSN
  • 0027-8874 (ISSN-L)
  • 1460-2105
OpenAlex
W2153909311
Cited by
92
References
3
FWCI
1.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.