A convolutional neural network approach for IMRT dose distribution prediction in prostate cancer patients
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The purpose of the study was to compare a 3D convolutional neural network (CNN) with the conventional machine learning method for predicting intensity-modulated radiation therapy (IMRT) dose distribution using only contours in prostate cancer. In this study, which included 95 IMRT-treated prostate cancer patients with available dose distributions and contours for planning target volume (PTVs) and organs at risk (OARs), a supervised-learning approach was used for training, where the dose for a voxel set in the dataset was defined as the label. The adaptive moment estimation algorithm was employed for optimizing a 3D U-net similar network. Eighty cases were used for the training and validation set in 5-fold cross-validation, and the remaining 15 cases were used as the test set. The predicted dose distributions were compared with the clinical dose distributions, and the model performance was evaluated by comparison with RapidPlan™. Dose–volume histogram (DVH) parameters were calculated for each contour as evaluation indexes. The mean absolute errors (MAE) with one standard deviation (1SD) between the clinical and CNN-predicted doses were 1.10% ± 0.64%, 2.50% ± 1.17%, 2.04% ± 1.40%, and 2.08% ± 1.99% for D2, D98 in PTV-1 and V65 in rectum and V65 in bladder, respectively, whereas the MAEs with 1SD between the clinical and the RapidPlan™-generated doses were 1.01% ± 0.66%, 2.15% ± 1.25%, 5.34% ± 2.13% and 3.04% ± 1.79%, respectively. Our CNN model could predict dose distributions that were superior or comparable with that generated by RapidPlan™, suggesting the potential of CNN in dose distribution prediction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Cited by
Revolutionizing radiation therapy: the role of AI in clinical practice
Kawamura, M., Kamomae, T., Yanagawa, M., Kamagata, K., Fujita, S., Ueda, D., Matsui, Y., Fushimi, Y., Fujioka, T., Nozaki, T., et al. (2024) · Journal of Radiation Research · doi:10.1093/jrr/rrad090 · Cited by 86
Barragán-Montero, A. M., Thomas, M., Defraene, G., Michiels, S., Haustermans, K., Lee, J. A., & Sterpin, E. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.02.026 · Cited by 69
A feasibility study of automating radiotherapy planning with large language model agents
Wang, Q., Wang, Z., Li, M., Ni, X., Tan, R., Zhang, W., Wubulaishan, M., Wang, W., Yuan, Z., Zhang, Z., et al. (2025) · Physics in Medicine & Biology · doi:10.1088/1361-6560/adbff1 · Cited by 28
“…predicting pixel-level or voxel-level dose distributions from patient anatomy, achieving significantly better predictive performance (Barragán-Montero et al 2019, Kajikawa et al 2019, Lee et al 2019, Nguyen et al 2019, Kandalan et al 2020, Murakami et al 2020, Shao et al 2020, Sumida et al 2020).”
A Survey on Deep Learning for Precision Oncology
Wang, C.-W., Khalil, M.-A., & Firdi, N. (2022) · Diagnostics · doi:10.3390/diagnostics12061489 · Cited by 23
Metadata
- Authors
- Kajikawa, T., Kadoya, N., Ito, K., Takayama, Y., Chiba, T., Tomori, S., Nemoto, H., Dobashi, S., Takeda, K., & Jingu, K.
- Venue
- Journal of Radiation Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2019-07-19
- Volume
- 60
- Issue
- 5
- Pages
- 685-693
- ISSN
- 0449-3060 (ISSN-L)
- 1349-9157
- OpenAlex
- W2963308874
- Cited by
- 78
- References
- 1
- FWCI
- 5.97
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.