BAC to the future! or oligonucleotides: a perspective for micro array comparative genomic hybridization (array CGH)
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
The array CGH technique (Array Comparative Genome Hybridization) has been developed to detect chromosomal copy number changes on a genome-wide and/or high-resolution scale. It is used in human genetics and oncology, with great promise for clinical application. Until recently primarily PCR amplified bacterial artificial chromosomes (BACs) or cDNAs have been spotted as elements on the array. The large-scale DNA isolations or PCR amplifications of the large-insert clones necessary for manufacturing the arrays are elaborate and time-consuming. Lack of a high-resolution highly sensitive (commercial) alternative has undoubtedly hindered the implementation of array CGH in research and diagnostics. Recently, synthetic oligonucleotides as arrayed elements have been introduced as an alternative substrate for array CGH, both by academic institutions as well as by commercial providers. Oligonucleotide libraries or ready-made arrays can be bought off-the-shelf saving considerable time and efforts. For RNA expression profiling, we have seen a gradual transition from in-house printed cDNA-based expression arrays to oligonucleotide arrays and we expect a similar transition for array CGH. This review compares the different platforms and will attempt to shine a light on the 'BAC to the future' of the array CGH technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comparative Genomic Hybridization for Molecular Cytogenetic Analysis of Solid Tumors
Kallioniemi, A., Kallioniemi, O.-P., Sudar, D., Rutovitz, D., Gray, J. W., Waldman, F., & Pinkel, D. (1992) · Science · doi:10.1126/science.1359641 · Cited by 3,297 · cited 2×
“Classical comparative genomic hybridization provided the possibility for detecting chromosomal copy number changes in cell and tissue samples, similar to karyotyping, without the need of culturing (1).”
BackgroundLarge-scale copy number polymorphism in the human genome
Sebat, J., Lakshmi, B., Troge, J., Alexander, J., Young, J., Lundin, P., Månér, S., Massa, H., Walker, M., Chi, M., et al. (2004) · Science · doi:10.1126/science.1098918 · Cited by 2,557 · cited 1×
“On the other hand, by using oligos that cover variable loci, the array CGH technique can be employed to measure these copy number variations (22,33,36,37).”
MethodPinkel, D., Segraves, R., Sudar, D., Clark, S., Poole, I., Kowbel, D., Collins, C., Kuo, W.-L., Chen, C., Zhai, Y., et al. (1998) · Nature Genetics · doi:10.1038/2524 · Cited by 2,240 · cited 1×
“53; BAC arrays (3), thin line with dots, slope 0.”
BackgroundGenome-wide analysis of DNA copy-number changes using cDNA microarrays
Pollack, J. R., Perou, C. M., Alizadeh, A. A., Eisen, M. B., Pergamenschikov, A., Williams, C. F., Jeffrey, S. S., Botstein, D., & Brown, P. O. (1999) · Nature Genetics · doi:10.1038/12640 · Cited by 1,423 · cited 3×
“The labeling protocol is basically the one used for the cDNA arrays (2) and requires 1 mg of input DNA which hampers the use of small clinical samples.”
MethodMatrix-based comparative genomic hybridization: Biochips to screen for genomic imbalances
Solinas-Toldo, S., Lampel, S., Stilgenbauer, S., Nickolenko, J., Benner, A., Döhner, H., Cremer, T., & Lichter, P. (1997) · Genes, Chromosomes and Cancer · doi:10.1002/(sici)1098-2264(199712)20:4<399::aid-gcc12>3.0.co;2-i · Cited by 1,002 · cited 1×
“Array CGH was introduced in the late nineties (4) and overcame these two major drawbacks.”
BackgroundAssembly of microarrays for genome-wide measurement of DNA copy number
Snijders, A. M., Nowak, N., Segraves, R., Blackwood, S., Brown, N., Conroy, J., Hamilton, G., Hindle, A. K., Huey, B., Kimura, K., et al. (2001) · Nature Genetics · doi:10.1038/ng754 · Cited by 999 · cited 7×
“Repeated hybridizations can separate the effects that sequence variation and technical noise have on the total variation (Table 1), which was carried out for both the BAC CGH and in-house printed oaCGH arrays using the BT474 cell line (14,18).”
BackgroundMethodInfluentialSelf-citationFine-scale structural variation of the human genome
Tuzun, E., Sharp, A. J., Bailey, J. A., Kaul, R., Morrison, V. A., Pertz, L. M., Haugen, E., Hayden, H., Albertson, D., Pinkel, D., et al. (2005) · Nature Genetics · doi:10.1038/ng1562 · Cited by 991 · cited 1×
“On the other hand, by using oligos that cover variable loci, the array CGH technique can be employed to measure these copy number variations (22,33,36,37).”
MethodSegmental Duplications and Copy-Number Variation in the Human Genome
Sharp, A. J., Locke, D. P., McGrath, S. D., Cheng, Z., Bailey, J. A., Vallente, R. U., Pertz, L. M., Clark, R. A., Schwartz, S., Segraves, R., et al. (2005) · The American Journal of Human Genetics · doi:10.1086/431652 · Cited by 972
A tiling resolution DNA microarray with complete coverage of the human genome
Ishkanian, A. S., Malloff, C. A., Watson, S. K., deLeeuw, R. J., Chi, B., Coe, B. P., Snijders, A., Albertson, D. G., Pinkel, D., Marra, M. A., et al. (2004) · Nature Genetics · doi:10.1038/ng1307 · Cited by 624 · cited 1×
“The venture for the production of a BAC array with a 1 Mb resolution, let alone a genome-covering array (21), is beyond the reach of most individual laboratories and as a consequence these arrays have not been widely available.”
BackgroundArray comparative genomic hybridization and its applications in cancer
Pinkel, D., & Albertson, D. G. (2005) · Nature Genetics · doi:10.1038/ng1569 · Cited by 585 · cited 5×
“Later, also the shorter cosmids and fosmids clones were introduced as spotted elements (5), as well as 130–600 bp single-stranded DNA molecules (10).”
BackgroundInfluential
Cited by
Global variation in copy number in the human genome
Redon, R., Ishikawa, S., Fitch, K. R., Feuk, L., Perry, G. H., Andrews, T. D., Fiegler, H., Shapero, M. H., Carson, A. R., Chen, W., et al. (2006) · Nature · doi:10.1038/nature05329 · Cited by 4,288
Miller, D. T., Adam, M. P., Aradhya, S., Biesecker, L. G., Brothman, A. R., Carter, N. P., Church, D. M., Crolla, J. A., Eichler, E. E., Epstein, C. J., et al. (2010) · The American Journal of Human Genetics · doi:10.1016/j.ajhg.2010.04.006 · Cited by 2,882
Hartgrink, H. H., Jansen, E. P., van Grieken, N. C., & van de Velde, C. J. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60617-6 · Cited by 875
High-resolution genomic profiling of chromosomal aberrations using Infinium whole-genome genotyping
Peiffer, D. A., Le, J. M., Steemers, F. J., Chang, W., Jenniges, T., Garcia, F., Haden, K., Li, J., Shaw, C. A., Belmont, J., et al. (2006) · Genome Research · doi:10.1101/gr.5402306 · Cited by 519
Scheinin, I., Sie, D., Bengtsson, H., van de Wiel, M. A., Olshen, A. B., van Thuijl, H. F., van Essen, H. F., Eijk, P. P., Rustenburg, F., Meijer, G. A., et al. (2014) · Genome Research · doi:10.1101/gr.175141.114 · Cited by 518
Self-citationMethods and strategies for analyzing copy number variation using DNA microarrays
Carter, N. P. (2007) · Nature Genetics · doi:10.1038/ng2028 · Cited by 510
Highly parallel genomic assays
Fan, J.-B., Chee, M. S., & Gunderson, K. L. (2006) · Nature Reviews Genetics · doi:10.1038/nrg1901 · Cited by 382
Andre, F., Job, B., Dessen, P., Tordai, A., Michiels, S., Liedtke, C., Richon, C., Yan, K., Wang, B., Vassal, G., et al. (2009) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-08-1791 · Cited by 336
Stankiewicz, P., & Beaudet, A. L. (2007) · Current Opinion in Genetics & Development · doi:10.1016/j.gde.2007.04.009 · Cited by 324
de Jong, D., Verbeke, S. L., Meijer, D., Hogendoorn, P. C., Bovee, J. V., & Szuhai, K. (2011) · BMC Research Notes · doi:10.1186/1756-0500-4-1 · Cited by 259
Shaffer, L. G., Bejjani, B. A., Torchia, B., Kirkpatrick, S., Coppinger, J., & Ballif, B. C. (2007) · American Journal of Medical Genetics Part C: Seminars in Medical Genetics · doi:10.1002/ajmg.c.30152 · Cited by 233
“size from 25–85 bp [Lucito et al., 2003; Ylstra et al., 2006], or can be larger cloned segments of DNA, such as bacterial artificial chromosomes (BACs) or P1 (PAC) clones that range in size from 75 to 200 Kb [Solinas-Toldo et al.”
BackgroundMolecular cytogenetic and rapid aneuploidy detection methods in prenatal diagnosis
Shaffer, L. G., & Bui, T. (2007) · American Journal of Medical Genetics Part C: Seminars in Medical Genetics · doi:10.1002/ajmg.c.30114 · Cited by 201
“Arrays can be constructed using various-sized targets ranging from oligonucleotides (25–85 bp) [Lucito et al., 2003; Ylstra et al., 2006] to bacterial artificial chromosomes (BACs; 80–200 kb) [Bejjani et al., 2005].”
BackgroundHughesman, C. B., Lu, X. J. D., Liu, K. Y. P., Zhu, Y., Poh, C. F., & Haynes, C. (2016) · PLOS ONE · doi:10.1371/journal.pone.0161274 · Cited by 46
Morozova, O., & Marra, M. A. (2008) · Biochemistry and Cell Biology · doi:10.1139/o08-003 · Cited by 46
Staaf, J., Törngren, T., Rambech, E., Johansson, U., Persson, C., Sellberg, G., Tellhed, L., Nilbert, M., & Borg, Å. (2008) · Human Mutation · doi:10.1002/humu.20678 · Cited by 44
“The accuracy by which genomic aberrations can be detected has consistently increased with the number of array elements applied, which is currently beyond 250,000 features per array [Ylstra et al., 2006].”
Background
Metadata
- Authors
- Ylstra, B.
- Venue
- Nucleic Acids Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-01-30
- Volume
- 34
- Issue
- 2
- Pages
- 445-450
- ISSN
- 0305-1048 (ISSN-L)
- 1362-4962
- OpenAlex
- W2097361093
- Cited by
- 207
- References
- 40
- FWCI
- 19.79
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.