Kinetic Outlier Detection (KOD) in real-time PCR
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Real-time PCR is becoming the method of choice for precise quantification of minute amounts of nucleic acids. For proper comparison of samples, almost all quantification methods assume similar PCR efficiencies in the exponential phase of the reaction. However, inhibition of PCR is common when working with biological samples and may invalidate the assumed similarity of PCR efficiencies. Here we present a statistical method, Kinetic Outlier Detection (KOD), to detect samples with dissimilar efficiencies. KOD is based on a comparison of PCR efficiency, estimated from the amplification curve of a test sample, with the mean PCR efficiency of samples in a training set. KOD is demonstrated and validated on samples with the same initial number of template molecules, where PCR is inhibited to various degrees by elevated concentrations of dNTP; and in detection of cDNA samples with an aberrant ratio of two genes. Translating the dissimilarity in efficiency to quantity, KOD identifies outliers that differ by 1.3-1.9-fold in their quantity from normal samples with a P-value of 0.05. This precision is higher than the minimal 2-fold difference in number of DNA molecules that real-time PCR usually aims to detect. Thus, KOD may be a useful tool for outlier detection in real-time PCR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wiesner, R. J., Rüegg, J. C., & Morano, I. (1992) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(92)90517-o · Cited by 197
Ståhlberg, A., Åman, P., Ridell, B., Mostad, P., & Kubista, M. (2003) · Clinical Chemistry · doi:10.1373/49.1.51 · Cited by 128 · cited 4×
“Variable PCR efficiency poses an important question whether to use identical PCR efficiency for relative quantification (1,2) or to adopt alternative quantification methods that rely on sample specific PCR efficiency (8, 9 ,11).”
BackgroundMethodResultInfluentialSelf-citation
Cited by
Hellemans, J., Mortier, G., De Paepe, A., Speleman, F., & Vandesompele, J. (2007) · Genome Biology · doi:10.1186/gb-2007-8-2-r19 · Cited by 4,023
Amplification efficiency: linking baseline and bias in the analysis of quantitative PCR data
Ruijter, J. M., Ramakers, C., Hoogaars, W. M. H., Karlen, Y., Bakker, O., van den Hoff, M. J. B., & Moorman, A. F. M. (2009) · Nucleic Acids Research · doi:10.1093/nar/gkp045 · Cited by 3,043
“(B) Comparison of amplification curves resulting from an optimal baseline (filled squares) with the curves resulting from 1% to 5% over-estimated (gray and open triangles) and 1% to 5% under-estimated baselines (gray and open circles) showing that the shape of the curves is dependent on the baseline estimate (21).”
InfluentialRNA integrity and the effect on the real-time qRT-PCR performance
Fleige, S., & Pfaffl, M. W. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.003 · Cited by 1,487
Comprehensive Algorithm for Quantitative Real-Time Polymerase Chain Reaction
Zhao, S., & Fernald, R. D. (2005) · Journal of Computational Biology · doi:10.1089/cmb.2005.12.1047 · Cited by 1,303
A standard curve based method for relative real time PCR data processing
Larionov, A., Krause, A., & Miller, W. (2005) · BMC Bioinformatics · doi:10.1186/1471-2105-6-62 · Cited by 946
Schefe, J. H., Lehmann, K. E., Buschmann, I. R., Unger, T., & Funke-Kaiser, H. (2006) · Journal of Molecular Medicine · doi:10.1007/s00109-006-0097-6 · Cited by 859
Properties of the Reverse Transcription Reaction in mRNA Quantification
Ståhlberg, A., Håkansson, J., Xian, X., Semb, H., & Kubista, M. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.026161 · Cited by 409
“, comparing the expression of genes in different samples, are possible by compensating for sample-to-sample variation in PCR efficiency by, for example, in situ calibration (2 ) or kinetic PCR (34, 35).”
BackgroundPCR inhibition in qPCR, dPCR and MPS—mechanisms and solutions
Sidstedt, M., Rådström, P., & Hedman, J. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02490-2 · Cited by 397
McKee, A. M., Spear, S. F., & Pierson, T. W. (2015) · Biological Conservation · doi:10.1016/j.biocon.2014.11.031 · Cited by 278
SPUD: A quantitative PCR assay for the detection of inhibitors in nucleic acid preparations
Nolan, T., Hands, R. E., Ogunkolade, W., & Bustin, S. A. (2006) · Analytical Biochemistry · doi:10.1016/j.ab.2006.01.051 · Cited by 257
Tuomi, J. M., Voorbraak, F., Jones, D. L., & Ruijter, J. M. (2010) · Methods · doi:10.1016/j.ymeth.2010.02.003 · Cited by 167
PCR inhibition by reverse transcriptase leads to an overestimation of amplification efficiency
Suslov, O. (2005) · Nucleic Acids Research · doi:10.1093/nar/gni176 · Cited by 121
“To retrieve Ct values the appropriate thresholds were set up as recommended [(11,12) and http:// www.”
Method
Metadata
- Authors
- Bar, T.
- Venue
- Nucleic Acids Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-09-01
- Volume
- 31
- Issue
- 17
- Pages
- 105e-105
- ISSN
- 0305-1048 (ISSN-L)
- 1362-4962
- OpenAlex
- W2100122767
- Cited by
- 102
- References
- 2
- FWCI
- 2.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.