The DOI matches its Crossref record.
Demonstration of preferential binding of SYBR Green I to specific DNA fragments in real-time multiplex PCR
Open accessAbstract
SYBR Green I (SG) is widely used in real-time PCR applications as an intercalating dye and is included in many commercially available kits at undisclosed concentrations. Binding of SG to double-stranded DNA is non-specific and additional testing, such as DNA melting curve analysis, is required to confirm the generation of a specific amplicon. The use of melt curve analysis eliminates the necessity for agarose gel electrophoresis because the melting temperature (T(m)) of the specific amplicon is analogous to the detection of an electrophoretic band. When using SG for real-time PCR multiplex reactions, discrimination of amplicons should be possible, provided the T(m) values are sufficiently different. Real-time multiplex assays for Vibrio cholerae and Legionella pneumophila using commercially available kits and in-house SG mastermixes have highlighted variability in performance characteristics, in particular the detection of only a single product as assessed by T(m) analysis but multiple products as assessed by agarose gel electrophoresis. The detected T(m) corresponds to the amplicon with the higher G+C% and larger size, suggesting preferential binding of SG during PCR and resulting in the failure to detect multiple amplicons in multiplex reactions when the amount of SG present is limiting. This has implications for the design and routine application of diagnostic real-time PCR assays employing SG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Smith, C. J., & Osborn, A. M. (2009) · FEMS Microbiology Ecology · doi:10.1111/j.1574-6941.2008.00629.x · Cited by 937
Zipper, H. (2004) · Nucleic Acids Research · doi:10.1093/nar/gnh101 · Cited by 791
Real-time reverse transcription PCR (qRT-PCR) and its potential use in clinical diagnosis
Bustin, S. A., & Mueller, R. (2005) · Clinical Science · doi:10.1042/cs20050086 · Cited by 529
PCR inhibition in qPCR, dPCR and MPS—mechanisms and solutions
Sidstedt, M., Rådström, P., & Hedman, J. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02490-2 · Cited by 397
Krypuy, M., Newnham, G. M., Thomas, D. M., Conron, M., & Dobrovic, A. (2006) · BMC Cancer · doi:10.1186/1471-2407-6-295 · Cited by 289
Metadata
- Authors
- Giglio, S.
- Venue
- Nucleic Acids Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-11-15
- Volume
- 31
- Issue
- 22
- Pages
- 136e-136
- ISSN
- 0305-1048 (ISSN-L)
- 1362-4962
- OpenAlex
- W1995295345
- Cited by
- 244
- References
- 0
- FWCI
- 3.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Demonstration of preferential binding of SYBR Green I to specific DNA fragments in real-time multiplex PCR. https://app.cochat.ai/papers/10.1093/nar/gng135
- The paper
- Giglio, S. (2003). Demonstration of preferential binding of SYBR Green I to specific DNA fragments in real-time multiplex PCR. Nucleic Acids Research. https://doi.org/10.1093/nar/gng135
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.