CoChat

Comparative performance of the BGI and Illumina sequencing technology for single-cell RNA-sequencing

Open access
Senabouth, Anne, Andersen, Stacey, Shi, Qianyu, Shi, Lei, Jiang, Feng, Zhang, Wenwei, Wing, Kristof, Daniszewski, Maciej, Lukowski, Samuel W, Hung, Sandy S C, Nguyen, Quan, Fink, Lynn, Beckhouse, Anthony, Pébay, Alice, Hewitt, Alex W, Powell, Joseph E · 2020 · NAR Genomics and Bioinformatics

Published version of a preprint

Cited by 53

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

The libraries generated by high-throughput single cell RNA-sequencing (scRNA-seq) platforms such as the Chromium from 10× Genomics require considerable amounts of sequencing, typically due to the large number of cells. The ability to use these data to address biological questions is directly impacted by the quality of the sequence data. Here we have compared the performance of the Illumina NextSeq 500 and NovaSeq 6000 against the BGI MGISEQ-2000 platform using identical Single Cell 3′ libraries consisting of over 70 000 cells generated on the 10× Genomics Chromium platform. Our results demonstrate a highly comparable performance between the NovaSeq 6000 and MGISEQ-2000 in sequencing quality, and the detection of genes, cell barcodes, Unique Molecular Identifiers. The performance of the NextSeq 500 was also similarly comparable to the MGISEQ-2000 based on the same metrics. Data generated by both sequencing platforms yielded similar analytical outcomes for general single-cell analysis. The performance of the NextSeq 500 and MGISEQ-2000 were also comparable for the deconvolution of multiplexed cell pools via variant calling, and detection of guide RNA (gRNA) from a pooled CRISPR single-cell screen. Our study provides a benchmark for high-capacity sequencing platforms applied to high-throughput scRNA-seq libraries.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/nargab/lqaa034

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Research works printed but not linked: 14

  1. Bentley, 2008, Accurate whole human genome sequencing using reversible terminator chemistry, Nature, 456, 53, 10.1038/nature07517 · DOI · Paper page
  2. van Dijk, 2014, Ten years of next-generation sequencing technology, Trends Genet., 30, 418, 10.1016/j.tig.2014.07.001 · DOI · Paper page
  3. Prakadan, 2017, Scaling by shrinking: empowering single-cell ‘omics’ with microfluidic devices, Nat. Rev. Genet., 18, 345, 10.1038/nrg.2017.15 · DOI · Paper page
  4. Hwang, 2018, Single-cell RNA sequencing technologies and bioinformatics pipelines, Exp. Mol. Med., 50, 96, 10.1038/s12276-018-0071-8 · DOI · Paper page
  5. Zheng, 2017, Massively parallel digital transcriptional profiling of single cells, Nat. Commun., 8, 14049, 10.1038/ncomms14049 · DOI · Paper page
  6. Fehlmann, 2016, cPAS-based sequencing on the BGISEQ-500 to explore small non-coding RNAs, Clin. Epigenet., 8, 123, 10.1186/s13148-016-0287-1 · DOI · Paper page
  7. Zhu, 2018, Comparative performance of the BGISEQ-500 and Illumina HiSeq4000 sequencing platforms for transcriptome analysis in plants, Plant Methods, 14, 69, 10.1186/s13007-018-0337-0 · DOI
  8. Natarajan, 2019, Comparative analysis of sequencing technologies for single-cell transcriptomics, Genome Biol., 20, 70, 10.1186/s13059-019-1676-5 · DOI · Paper page
  9. Daniszewski, 2018, Single-cell profiling identifies key pathways expressed by iPSCs cultured in different commercial media, iScience, 7, 30, 10.1016/j.isci.2018.08.016 · DOI
  10. Huang, 2017, A reference human genome dataset of the BGISEQ-500 sequencer, Gigascience, 6, 1, 10.1093/gigascience/gix024 · DOI · Paper page
  11. Dobin, 2013, STAR: ultrafast universal RNA-seq aligner, Bioinformatics, 29, 15, 10.1093/bioinformatics/bts635 · DOI · Paper page
  12. Griffiths, 2018, Detection and removal of barcode swapping in single-cell RNA-seq data, Nat. Commun., 9, 2667, 10.1038/s41467-018-05083-x · DOI · Paper page
  13. Stuart, 2019, Comprehensive integration of single-cell data, Cell, 177, 1888, 10.1016/j.cell.2019.05.031 · DOI · Paper page
  14. Andrews, 2018, M3Drop: dropout-based feature selection for scRNASeq, Bioinformatics, 35, 2865, 10.1093/bioinformatics/bty1044 · DOI · Paper page

Cited by

See all 53

Metadata

Authors
Senabouth, A., Andersen, S., Shi, Q., Shi, L., Jiang, F., Zhang, W., Wing, K., Daniszewski, M., Lukowski, S. W., Hung, S. S. C., Nguyen, Q., Fink, L., Beckhouse, A., Pébay, A., Hewitt, A. W., & Powell, J. E.
Venue
NAR Genomics and Bioinformatics
Published
2020-05-13
Volume
2
Issue
2
Pages
lqaa034-lqaa034
ISSN
2631-9268 (ISSN-L)
OpenAlex
W3024314143
Cited by
53
References
9
FWCI
2.35
Type
journal article
Language
en
Open access
gold
Funders
  • National Health and Medical Research Council (APP1132719, APP1083405, APP1107599)
  • Stem Cells Australia
  • Macular Disease Foundation Australia
  • Yulgilbar Foundation
  • NHMRC Practitioner Fellowship (1103329)
  • NHMRC Senior Research Fellowship (1154389)
  • Australian Research Council Future Fellowship (FT140100047)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparative performance of the BGI and Illumina sequencing technology for single-cell RNA-sequencing. https://app.cochat.ai/papers/10.1093/nargab/lqaa034
The paper
Senabouth, A., Andersen, S., Shi, Q., Shi, L., Jiang, F., Zhang, W., Wing, K., Daniszewski, M., Lukowski, S. W., Hung, S. S. C., Nguyen, Q., Fink, L., Beckhouse, A., Pébay, A., Hewitt, A. W., & Powell, J. E. (2020). Comparative performance of the BGI and Illumina sequencing technology for single-cell RNA-sequencing. NAR Genomics and Bioinformatics. https://doi.org/10.1093/nargab/lqaa034

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.