CoChat

What is hypertension in chronic haemodialysis? The role of interdialytic blood pressure monitoring

Mitra, Sandip, Chandna, Shahid M., Farrington, Ken · 1999 · Nephrology Dialysis Transplantation
Cited by 66

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Hypertension in chronic haemodialysis patients contributes significantly to morbidity and mortality. Treatment decisions are usually based on predialysis readings, which may not accurately reflect control during the interdialytic period. METHODS: We studied 40 randomly selected subjects on haemodialysis and compared readings by different methods at set times during the dialysis session with the 48-h interdialytic ambulatory readings. Conventional sphygmomanometer, automated Dinamap and Tm 2421(A&D) ambulatory monitor were used for BP measurements. RESULTS: Conventional sphygmomanometry and self measured automatic readings (Dinamap) were highly correlated (systolic r=0.93, P<0.001; diastolic r=0.90, P<0.001). Mean blood pressure on arrival ((PreC(0)) 158 mmHg systolic, 80 mmHg diastolic and 106 mmHg mean) significantly overestimated the mean ambulatory reading during the 6 h prior to attendance ((preAm(6h)) systolic 147 (P<0.01), diastolic 75 (P<0.01), mean 99 (P<0.01)). Fifteen patients (41%) demonstrated a marked difference (>20/10 mmHg) between the PreC(0) and preAm(6h) (white-coat effect) persisting in seven patients (19%) after a period of rest 10 min predialysis (preC(10)) and present even in self-recorded Dinamap readings. There was a significant negative relationship between the systolic rise and the number of months on dialysis (P<0.05). Mean ambulatory BP on interdialytic day 2 was significantly greater than on day 1 whereas the awake-sleep differences were less on day 2 than day 1, both perhaps reflecting differences in volume status. The 20 min post-dialysis measurement (PoC(20)) for systolic, diastolic, and mean, unlike predialysis (PreC(0) and preC(10)), onset (onC) and end of dialysis readings (enC) did not differ significantly from 48 h interdialytic means. CONCLUSIONS: The best representation of interdialytic pressure was the 20-min post-dialysis reading. Walk-in predialysis pressures overestimate mean interdialytic pressures due to a high incidence of white-coat effect, which shows some habituation with time on dialysis. Ambulatory monitoring has a role in evaluating persistent poor blood pressure control in haemodialysis patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ndt/14.12.2915

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 66

Metadata

Authors
Mitra, S., Chandna, S. M., & Farrington, K.
Venue
Nephrology Dialysis Transplantation
Published
1999-12-01
Volume
14
Issue
12
Pages
2915-2921
ISSN
  • 0931-0509 (ISSN-L)
  • 1460-2385
OpenAlex
W2124619474
Cited by
66
References
1
FWCI
1.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: What is hypertension in chronic haemodialysis? The role of interdialytic blood pressure monitoring. https://app.cochat.ai/papers/10.1093/ndt/14.12.2915
The paper
Mitra, S., Chandna, S. M., & Farrington, K. (1999). What is hypertension in chronic haemodialysis? The role of interdialytic blood pressure monitoring. Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/14.12.2915

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.