Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 210

The DOI matches its Crossref record.

The role of iron status markers in predicting response to intravenous iron in haemodialysis patients on maintenance erythropoietin

Tessitore, Nicola, Solero, Giovanni Pietro, Lippi, Giuseppe, Bassi, Antonella, Faccini, Giovanni Battista, Bedogna, Valeria, Gammaro, Linda, Brocco, Giorgio, Restivo, Giuseppe, Bernich, Patrizia, Lupo, Antonio, Maschio, Giuseppe·2001·Nephrology Dialysis Transplantation

Abstract

BACKGROUND: Iron deficiency (ID) is the main cause of hyporesponsiveness to erythropoietin in haemodialysis patients and its detection is of value since it is easily corrected by intravenous iron. Markers of iron supply to the erythron, including erythrocyte zinc protoporphyrin (Er-ZPP), percentage of hypochromic erythrocytes (Hypo), reticulocyte haemoglobin content (CHr) and soluble transferrin receptor (sTfR), may be more accurate predictors of ID than ferritin (Fer) and transferrin saturation (TSat), but relative diagnostic power and best threshold values are not yet established. METHODS: In 125 haemodialysis patients on maintenance erythropoietin, the diagnostic power of the above parameters was evaluated by ROC curve, multivariate regression, and stepwise discriminant analyses. Diagnosis of ID was based on haemoglobin response to intravenous iron (992 mg as sodium ferric gluconate complex over an 8-week period). RESULTS: Fifty-one patients were considered iron deficient (haemoglobin increase by 1.9+/-0.5 g/dl) and 74 as iron replete (haemoglobin increase by 0.4+/-0.3 g/dl). ROC curve analysis showed that all tests had discriminative ability with the following hierarchy: Hypo (area under curve W=0.930, efficiency 89.6% at cut-off >6%), CHr (W=0.798, efficiency 78.4% at cut-off < or =29 pg), sTfR (W=0.783, efficiency 72.4% at cut-off >1.5 mg/l), Er-ZPP (W=0.773, efficiency 73.0% at cut-off >52 micromol/mol haem), TSat (W=0.758, efficiency 70.4% at cut-off <19%) and ferritin (W=0.633, efficiency 64.0% at cut-off <50 ng/ml). Stepwise discriminant analysis identified Hypo as the only variable with independent diagnostic value, able to classify 87.2% of patients correctly. Additional tests did not substantially improve diagnostic efficiency of Hypo >6% alone. CONCLUSIONS: In haemodialysis patients on maintenance erythropoietin, Hypo >6% is the best currently available marker to identify those who will improve their response after intravenous iron. Cost-effectiveness suggests that this parameter should be a first-line tool to monitor iron requirements in clinical practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ndt/16.7.1416

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 210

Metadata

Authors
Tessitore, N., Solero, G. P., Lippi, G., Bassi, A., Faccini, G. B., Bedogna, V., Gammaro, L., Brocco, G., Restivo, G., Bernich, P., Lupo, A., & Maschio, G.
Venue
Nephrology Dialysis Transplantation
Published
2001-07-01
Volume
16
Issue
7
Pages
1416-1423
ISSN
  • 0931-0509 (ISSN-L)
  • 1460-2385
OpenAlex
W2109138011
Cited by
210
References
0
FWCI
3.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The role of iron status markers in predicting response to intravenous iron in haemodialysis patients on maintenance erythropoietin. https://app.cochat.ai/papers/10.1093/ndt/16.7.1416
The paper
Tessitore, N., Solero, G. P., Lippi, G., Bassi, A., Faccini, G. B., Bedogna, V., Gammaro, L., Brocco, G., Restivo, G., Bernich, P., Lupo, A., & Maschio, G. (2001). The role of iron status markers in predicting response to intravenous iron in haemodialysis patients on maintenance erythropoietin. Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/16.7.1416

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.