Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 391

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Ferric Gluconate Is Highly Efficacious in Anemic Hemodialysis Patients with High Serum Ferritin and Low Transferrin Saturation: Results of the Dialysis Patients’ Response to IV Iron with Elevated Ferritin (DRIVE) Study

Coyne, Daniel W., Kapoian, Toros, Suki, Wadi, Singh, Ajay K., Moran, John E., Dahl, Naomi V., Rizkala, Adel R.·2007·Journal of the American Society of Nephrology

Abstract

Few data exist to guide treatment of anemic hemodialysis patients with high ferritin and low transferrin saturation (TSAT). The Dialysis Patients' Response to IV Iron with Elevated Ferritin (DRIVE) trial was designed to evaluate the efficacy of intravenous ferric gluconate in such patients. Inclusion criteria were hemoglobin or=225 IU/kg per wk or >or=22,500 IU/wk. Patients with known infections or recent significant blood loss were excluded. Participants (n=134) were randomly assigned to no iron (control) or to ferric gluconate 125 mg intravenously with eight consecutive hemodialysis sessions (intravenous iron). At randomization, epoetin was increased 25% in both groups; further dosage changes were prohibited. At 6 wk, hemoglobin increased significantly more (P=0.028) in the intravenous iron group (1.6 +/- 1.3 g/dl) than in the control group (1.1 +/- 1.4 g/dl). Hemoglobin response occurred faster (P=0.035) and more patients responded after intravenous iron than in the control group (P=0.041). Ferritin 800 ng/ml had no relationship to the magnitude or likelihood of responsiveness to intravenous iron relative to the control group. Similarly, the superiority of intravenous iron compared with no iron was similar whether baseline TSAT was above or below the study median of 19%. Ferritin decreased in control subjects (-174 +/- 225 ng/ml) and increased after intravenous iron (173 +/- 272 ng/ml; P<0.001). Intravenous iron resulted in a greater increase in TSAT than in control subjects (7.5 +/- 7.4 versus 1.8 +/- 5.2%; P<0.001). Reticulocyte hemoglobin content fell only in control subjects, suggesting worsening iron deficiency. Administration of ferric gluconate (125 mg for eight treatments) is superior to no iron therapy in anemic dialysis patients receiving adequate epoetin dosages and have a ferritin 500 to 1200 ng/ml and TSAT

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1681/asn.2006091034

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 391

Metadata

Authors
Coyne, D. W., Kapoian, T., Suki, W., Singh, A. K., Moran, J. E., Dahl, N. V., & Rizkala, A. R.
Venue
Journal of the American Society of Nephrology
Published
2007-03
Volume
18
Issue
3
Pages
975-984
ISSN
1046-6673 (ISSN-L)
OpenAlex
W2144758554
Cited by
391
References
25
FWCI
22.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ferric Gluconate Is Highly Efficacious in Anemic Hemodialysis Patients with High Serum Ferritin and Low Transferrin Saturation: Results of the Dialysis Patients’ Response to IV Iron with Elevated Ferritin (DRIVE) Study. https://app.cochat.ai/papers/10.1681/asn.2006091034
The paper
Coyne, D. W., Kapoian, T., Suki, W., Singh, A. K., Moran, J. E., Dahl, N. V., & Rizkala, A. R. (2007). Ferric Gluconate Is Highly Efficacious in Anemic Hemodialysis Patients with High Serum Ferritin and Low Transferrin Saturation: Results of the Dialysis Patients’ Response to IV Iron with Elevated Ferritin (DRIVE) Study. Journal of the American Society of Nephrology. https://doi.org/10.1681/asn.2006091034

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.