The DOI matches its Crossref record.
Non-dipping is a potent predictor of cardiovascular mortality and is associated with autonomic dysfunction in haemodialysis patients
Abstract
BACKGROUND: Lack of nocturnal blood pressure (BP) fall (non-dipping) is common among haemodialysis (HD) patients, but much less is known regarding its association with cardiovascular (CV) disease morbidity and mortality. METHODS: Eighty HD patients initially underwent 24 h ambulatory BP monitoring (ABPM), and then they were defined as either 'dippers' (n=24, nocturnal BP fall > or = 10%) or 'non-dippers' (n=56, fall <10%). Coronary angiography was performed in the patients who had signs and/or symptoms of coronary artery disease (CAD). Twenty-four hour ambulatory ECG was recorded in 20 dippers and 20 non-dipper HD patients, and in 20 normal subjects. All patients were followed for up to 5.8 years (33.0+/-19.1 months). The outcome events studied were the hospitalisations due to CV diseases and CV death. RESULTS: Compared with dippers, non-dippers initially had a higher incidence of coronary artery stenosis (P<0.05) along with left ventricular asynergy (both Ps<0.01). The circadian rhythm of autonomic function was impaired in non-dippers. The incidences of CV events and CV deaths were 3.5 and 9 times higher in non-dippers than in dippers. The cumulative CV event-free survival and CV survival rates were lower in non-dippers than in dippers (P=0.02 and P=0.005, respectively). Based on Cox analysis, non-dipping was associated positively with CV events and CV mortality [hazard ratio (HR) 2.46, 95% CI 1.02-5.92, P=0.038 and HR 9.62, 95% CI 1.23-75.42, P=0.031, respectively]. Meanwhile, nocturnal systolic BP fall, diurnal systolic BP and diurnal pulse pressure were negatively associated with CV event/death. The clinic BP was not associated with CV event/death. CONCLUSIONS: The non-dipping phenomenon is closely related to a high incidence of CV diseases, a poor long-term survival and profound autonomic dysfunction. ABPM is useful in predicting long-term CV prognosis in HD patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Twenty-four-hour ambulatory blood pressure in children with sleep-disordered breathing
Amin, R. S., Carroll, J. L., Jeffries, J. L., Grone, C., Bean, J. A., Chini, B., Bokulic, R., & Daniels, S. R. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200309-1305oc · Cited by 354
Circadian clock-mediated regulation of blood pressure
Douma, L. G., & Gumz, M. L. (2018) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2017.11.024 · Cited by 266
Agarwal, R., & Andersen, M. J. (2006) · Kidney International · doi:10.1038/sj.ki.5000247 · Cited by 252
Epidemiology of hypertensive kidney disease
Udani, S., Lazich, I., & Bakris, G. L. (2011) · Nature Reviews Nephrology · doi:10.1038/nrneph.2010.154 · Cited by 171
Metadata
- Authors
- Liu, M.
- Venue
- Nephrology Dialysis Transplantation
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-03-01
- Volume
- 18
- Issue
- 3
- Pages
- 563-569
- ISSN
- 0931-0509 (ISSN-L)
- 1460-2385
- OpenAlex
- W2144925396
- Cited by
- 230
- References
- 0
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-dipping is a potent predictor of cardiovascular mortality and is associated with autonomic dysfunction in haemodialysis patients. https://app.cochat.ai/papers/10.1093/ndt/18.3.563
- The paper
- Liu, M. (2003). Non-dipping is a potent predictor of cardiovascular mortality and is associated with autonomic dysfunction in haemodialysis patients. Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/18.3.563
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.