Hypersensitivity reactions and deaths associated with intravenous iron preparations
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Parenteral iron therapy is an accepted adjunctive management of anaemia in kidney disease. Newer agents may have fewer severe hypersensitivity adverse events (AE) compared with iron dextrans (ID). The rate of type 1 AE to iron sucrose (IS) and sodium ferric gluconate (SFG) relative to ID is unclear. We used the US Food and Drug Administration's Freedom of Information (FOI) surveillance database to compare the type 1 AE profiles for the three intravenous iron preparations available in the United States. METHODS: We tabulated reports received by the FOI database between January 1997 and September 2002, and calculated 100 mg dose equivalents for the treated population for each agent. We developed four clinical categories describing hypersensitivity AE (anaphylaxis, anaphylactoid reaction, urticaria and angioedema) and an algorithm describing anaphylaxis, for specific analyses. RESULTS: All-event reporting rates were 29.2, 10.5 and 4.2 reports/million 100 mg dose equivalents, while all-fatal-event reporting rates were 1.4, 0.6 and 0.0 reports/million 100 mg dose equivalents for ID, SFG and IS, respectively. ID had the highest reporting rates in all four clinical categories and the anaphylaxis algorithm. SFG had intermediate reporting rates for urticaria, anaphylactoid reaction and the anaphylaxis algorithm, and a zero reporting rate for the anaphylaxis clinical category. IS had either the lowest or a zero reporting rate in all clinical categories/algorithm. CONCLUSIONS: These findings confirm a higher risk for AE, especially serious type 1 reactions, with ID therapy than with newer intravenous iron products and also suggest that IS carries the lowest risk for hypersensitivity reactions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Szarfman, A., Machado, S. G., & O??Neill, R. T. (2002) · Drug Safety · doi:10.2165/00002018-200225060-00001 · Cited by 700
Advances in Inflammation Research.
(1980) · Annals of Internal Medicine · doi:10.7326/0003-4819-92-6-885_1 · Cited by 387
Antidepressant-Induced Sexual Dysfunction
Gregorian, R. S., Golden, K. A., Bahce, A., Goodman, C., Kwong, W. J., & Khan, Z. M. (2002) · Annals of Pharmacotherapy · doi:10.1345/aph.1a195 · Cited by 320
Intravenous Iron Dextran in Clinical Medicine
Hamstra, R. D. (1980) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1980.03300430028018 · Cited by 280
The safety of intravenous iron dextran in hemodialysis patients
Fishbane, S., Ungureanu, V.-D., Maesaka, J. K., Kaupke, C. J., Lim, V., & Wish, J. (1996) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(96)90463-1 · Cited by 272
Adverse-Drug-Reaction Monitoring
Faich, G. A. (1986) · New England Journal of Medicine · doi:10.1056/nejm198606123142427 · Cited by 223
Sodium ferric gluconate complex in sucrose: Safer intravenous iron therapy than iron dextrans
Faich, G., & Strobos, J. (1999) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(99)70183-6 · Cited by 208 · cited 6×
“The analysis of case fatality proportion is also consistent with previous studies [1,16].”
BackgroundMethodResultInfluentialOn the relative safety of parenteral iron formulations
Chertow, G. M., Mason, P. D., Vaage-Nilsen, O., & Ahlmen, J. (2004) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfh185 · Cited by 150 · cited 2×
“A more recent study also used data derived from the FDA to compare the reaction rates of high and low molecular weight formulations of iron dextran and sodium ferric gluconate [5].”
MethodResultSuspected iron dextran-related adverse drug events in hemodialysis patients
Fletes, R., Lazarus, J. M., Gage, J. O., & Chertow, G. M. (2001) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(01)80123-2 · Cited by 135
Effects of Development on Olanzapine-Associated Adverse Events
Woods, S. W., Martin, A., SPECTOR, S. G., & McGlashan, T. H. (2002) · Journal of the American Academy of Child & Adolescent Psychiatry · doi:10.1097/00004583-200212000-00015 · Cited by 116 · cited 1×
“The FOI Database Reactions File can be linked to information about patient demographics, report sources, drug therapies, dates of therapeutic administration and patient outcomes [10].”
Background
Cited by
Drug Allergy: An Updated Practice Parameter
(2010) · Annals of Allergy, Asthma & Immunology · doi:10.1016/j.anai.2010.08.002 · Cited by 957
Update on adverse drug events associated with parenteral iron
Chertow, G. M., Mason, P. D., Vaage-Nilsen, O., & Ahlmén, J. (2006) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfi253 · Cited by 457
KDIGO clinical practice guidelines for bisphosphonate treatment in chronic kidney disease
Woo, K. T., & Chan, C. M. (2011) · Kidney International · doi:10.1038/ki.2011.202 · Cited by 412
Ferumoxytol for Treating Iron Deficiency Anemia in CKD
Spinowitz, B. S., Kausz, A. T., Baptista, J., Noble, S. D., Sothinathan, R., Bernardo, M. V., Brenner, L., & Pereira, B. J. G. (2008) · Journal of the American Society of Nephrology · doi:10.1681/asn.2007101156 · Cited by 262
The Pharmacokinetics and Pharmacodynamics of Iron Preparations
Geisser, P., & Burckhardt, S. (2011) · Pharmaceutics · doi:10.3390/pharmaceutics3010012 · Cited by 230
“2 for iron dextran) [60].”
Background
Metadata
- Authors
- Bailie, G. R., Clark, J. A., Lane, C. E., & Lane, P. L.
- Venue
- Nephrology Dialysis Transplantation
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-04-26
- Volume
- 20
- Issue
- 7
- Pages
- 1443-1449
- ISSN
- 0931-0509 (ISSN-L)
- 1460-2385
- OpenAlex
- W2130938704
- Cited by
- 164
- References
- 10
- FWCI
- 14.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).