Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 164

The DOI matches its Crossref record.

Cannulating in haemodialysis: rope-ladder or buttonhole technique?

Open access
Verhallen, A. M., Kooistra, M. P., van Jaarsveld, B. C. · 2007 · Nephrology Dialysis Transplantation

Abstract

BACKGROUND: The standard technique for fistula cannulation, the rope-ladder technique, is problematic for patients with short fistula lengths and for patients in whom the fistula is difficult to cannulate. The buttonhole technique, cannulation of exactly the same site, offers the advantage of an easy cannulation procedure. However, it can be used only in native fistulas and cannulation is preferably executed by a 'single-sticker'. This study was conducted to compare these cannulation techniques using objective parameters. METHODS: We introduced the buttonhole technique for self-cannulating home haemodialysis patients and compared it with baseline data obtained with the rope-ladder technique. Thirty-three patients with a native arteriovenous fistula were observed prospectively during 18 months on the following parameters: cannulating ease, number of bad sticks, pain, time of compression after cannula removal, bleeding, infectious complications and aneurysm formation. RESULTS: With the buttonhole method, cannulating ease improved distinctly, which was especially favourable in patients with a short fistula vein. Reported cannulation pain did not change significantly. The incidence of bad sticks decreased significantly, as well as time of compression after cannula removal, without increased incidence of bleeding. Three patients developed a local skin infection of their buttonhole during the study, after which the disinfection routine prior to cannulation was changed. CONCLUSIONS: Compared with the rope-ladder technique, the buttonhole method offers the advantage of an easier cannulation procedure with less bad sticks, which has a special benefit for patients with limited access cannulation sites or with a fistula which is difficult to cannulate. Prolonged compression times or re-bleeding episodes did not occur, but precautions have to be taken in order to prevent infectious complications. The buttonhole method can contribute considerably to the cannulating ease of self-cannulating patients, thus providing a better quality of life.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ndt/gfm043

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 164

Metadata

Authors
Verhallen, A. M., Kooistra, M. P., & van Jaarsveld, B. C.
Venue
Nephrology Dialysis Transplantation
Published
2007-06-05
Volume
22
Issue
9
Pages
2601-2604
ISSN
  • 0931-0509 (ISSN-L)
  • 1460-2385
OpenAlex
W2131290285
Cited by
164
References
0
FWCI
15.55
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cannulating in haemodialysis: rope-ladder or buttonhole technique? https://app.cochat.ai/papers/10.1093/ndt/gfm043
The paper
Verhallen, A. M., Kooistra, M. P., & van Jaarsveld, B. C. (2007). Cannulating in haemodialysis: rope-ladder or buttonhole technique? Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/gfm043

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.