CoChat

Glycaemic control in type 2 diabetic patients on chronic haemodialysis: use of a continuous glucose monitoring system

Riveline, Jean-Pierre, Teynie, Julie, Belmouaz, Simohamed, Franc, Sylvia, Dardari, Dured, Bauwens, Marc, Caudwell, Valérie, Ragot, Stéphanie, Bridoux, Frank, Charpentier, Guillaume, Marechaud, Richard, Hadjadj, Samy · 2009 · Nephrology Dialysis Transplantation
Cited by 133

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The proportion of diabetic patients undergoing haemodialysis is rapidly increasing. Glucose control among such patients is difficult to assess. We aimed to evaluate the clinical performance of a continuous glucose monitoring system (CGMS) in type 2 diabetic patients on chronic haemodialysis. METHODS: We used a 4-day CGMS to monitor glucose levels in 19 haemodialysed type 2 diabetic patients (HD T2) including 2 days with and 2 days without dialysis session, and 39 non-HD T2 in a double-centre study. RESULTS: The glucose concentration according to the glucose meter and CGMS were correlated in HD T2 patients (r = 0.90, P < 0.0001) and in non-HD T2 patients (r = 0.81, P < 0.0001). The relative absolute difference (RAD) between glucose determined by a glucose meter and glucose determined by the CGMS did not differ between HD T2 and non-HD T2 patients (9.2 +/- 10.5 vs. 8.2 +/- 7.6%; P = 0.165). Glycated haemoglobin (A1c) and mean glucose concentration were strongly correlated in non-HD T2 patients (r = 0.71; P < 0.0001) but weakly correlated in HD T2 patients (r = 0.47; P = 0.042). Fructosamine was correlated with the mean glucose concentration in non-HD T2 (r = 0.67; P < 0.0001) but not in HD T2 patients (r = 0.04; P = 0.88). CONCLUSION: CGM is a validated marker of glycaemic control in HD diabetic patients. This tool showed that A1c and fructosamine, despite being good markers of glycaemic control in non-HD diabetic patients, are of poor value in HD diabetic patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ndt/gfp181

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 133

Metadata

Authors
Riveline, J.-P., Teynie, J., Belmouaz, S., Franc, S., Dardari, D., Bauwens, M., Caudwell, V., Ragot, S., Bridoux, F., Charpentier, G., Marechaud, R., & Hadjadj, S.
Venue
Nephrology Dialysis Transplantation
Published
2009-04-23
Volume
24
Issue
9
Pages
2866-2871
ISSN
  • 0931-0509 (ISSN-L)
  • 1460-2385
OpenAlex
W2158008046
Cited by
133
References
13
FWCI
5.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.