The DOI matches its Crossref record.
Buttonhole needling of haemodialysis arteriovenous fistulae results in less complications and interventions compared to the rope-ladder technique
Open accessAbstract
BACKGROUND: The rope-ladder puncture technique, with cannulation along the whole length of the vessel traject, has been very common in haemodialysis patients with autogenous arterio-venous fistula (AVF). Today's dialysis population with AVF may exhibit difficult cannulation, because of a short vein length or a complicated cannulation route. An alternative needling possibility is the buttonhole (BH) technique, which inserts needles at exactly the same location during every dialysis session. The present study was conducted to investigate the effect of both cannulation techniques on the incidence of vascular access (VA) complications. METHODS: A total of 75 prevalent haemodialysis patients with autogenous AVF using the BH technique were compared with 70 patients using the rope-ladder technique. The following parameters were registered: haematoma occurrence, redness, swelling, aneurysm formation, the use of sharp or dull needles, miscannulations, and interventions. Needling pain and fear of puncture were assessed using a verbal rating scale (VRS). The duration of the follow-up was 9 months. RESULTS: Patients in the BH group had more unsuccessful cannulations, compared with the rope-ladder method (P < 0.0001), but the frequency of haematoma (P < 0.0001) and aneurysm formation (P < 0.0001) was less. In addition, intervention such as angioplasty (P < 0.0001) was higher in patients using the rope-ladder technique. A negative outcome of the BH technique was the higher incidence of access infections compared to the rope-ladder method. CONCLUSION: This study showed that the BH method is a valuable technique with few complications like haematoma, aneurysm formation and the need for interventions. However, the infections induced by the BH method should not be underestimated. This underlines the importance of an aseptic and correct technique of the buttonhole procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Schmidli, J., Widmer, M. K., Basile, C., de Donato, G., Gallieni, M., Gibbons, C. P., Haage, P., Hamilton, G., Hedin, U., Kamper, L., et al. (2018) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2018.02.001 · Cited by 878
Self-citationFactors affecting the patency of arteriovenous fistulas for dialysis access
Smith, G. E., Gohil, R., & Chetter, I. C. (2012) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2011.07.095 · Cited by 271
Guía Clínica Española del Acceso Vascular para Hemodiálisis
Ibeas, J., Roca-Tey, R., Vallespín, J., Moreno, T., Moñux, G., Martí-Monrós, A., del Pozo, J. L., Gruss, E., Ramírez de Arellano, M., Fontseré, N., et al. (2017) · Nefrología · doi:10.1016/j.nefro.2017.11.004 · Cited by 214
Staaf, K., Fernström, A., & Uhlin, F. (2021) · BMC Nephrology · doi:10.1186/s12882-021-02458-z · Cited by 26
Update on Cannulation Techniques
Twardowski, Z. J. (2015) · The Journal of Vascular Access · doi:10.5301/jva.5000349 · Cited by 23
Metadata
- Authors
- van Loon, M. M., Goovaerts, T., Kessels, A. G. H., van der Sande, F. M., & Tordoir, J. H. M.
- Venue
- Nephrology Dialysis Transplantation
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-08-29
- Volume
- 25
- Issue
- 1
- Pages
- 225-230
- ISSN
- 0931-0509 (ISSN-L)
- 1460-2385
- OpenAlex
- W2123287489
- Cited by
- 210
- References
- 0
- FWCI
- 23.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Buttonhole needling of haemodialysis arteriovenous fistulae results in less complications and interventions compared to the rope-ladder technique. https://app.cochat.ai/papers/10.1093/ndt/gfp420
- The paper
- van Loon, M. M., Goovaerts, T., Kessels, A. G. H., van der Sande, F. M., & Tordoir, J. H. M. (2010). Buttonhole needling of haemodialysis arteriovenous fistulae results in less complications and interventions compared to the rope-ladder technique. Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/gfp420
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.