Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 210

The DOI matches its Crossref record.

Buttonhole needling of haemodialysis arteriovenous fistulae results in less complications and interventions compared to the rope-ladder technique

Open access
van Loon, M. M., Goovaerts, T., Kessels, A. G. H., van der Sande, F. M., Tordoir, J. H. M.·2010·Nephrology Dialysis Transplantation

Abstract

BACKGROUND: The rope-ladder puncture technique, with cannulation along the whole length of the vessel traject, has been very common in haemodialysis patients with autogenous arterio-venous fistula (AVF). Today's dialysis population with AVF may exhibit difficult cannulation, because of a short vein length or a complicated cannulation route. An alternative needling possibility is the buttonhole (BH) technique, which inserts needles at exactly the same location during every dialysis session. The present study was conducted to investigate the effect of both cannulation techniques on the incidence of vascular access (VA) complications. METHODS: A total of 75 prevalent haemodialysis patients with autogenous AVF using the BH technique were compared with 70 patients using the rope-ladder technique. The following parameters were registered: haematoma occurrence, redness, swelling, aneurysm formation, the use of sharp or dull needles, miscannulations, and interventions. Needling pain and fear of puncture were assessed using a verbal rating scale (VRS). The duration of the follow-up was 9 months. RESULTS: Patients in the BH group had more unsuccessful cannulations, compared with the rope-ladder method (P < 0.0001), but the frequency of haematoma (P < 0.0001) and aneurysm formation (P < 0.0001) was less. In addition, intervention such as angioplasty (P < 0.0001) was higher in patients using the rope-ladder technique. A negative outcome of the BH technique was the higher incidence of access infections compared to the rope-ladder method. CONCLUSION: This study showed that the BH method is a valuable technique with few complications like haematoma, aneurysm formation and the need for interventions. However, the infections induced by the BH method should not be underestimated. This underlines the importance of an aseptic and correct technique of the buttonhole procedure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ndt/gfp420

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 210

Metadata

Authors
van Loon, M. M., Goovaerts, T., Kessels, A. G. H., van der Sande, F. M., & Tordoir, J. H. M.
Venue
Nephrology Dialysis Transplantation
Published
2009-08-29
Volume
25
Issue
1
Pages
225-230
ISSN
  • 0931-0509 (ISSN-L)
  • 1460-2385
OpenAlex
W2123287489
Cited by
210
References
0
FWCI
23.25
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Buttonhole needling of haemodialysis arteriovenous fistulae results in less complications and interventions compared to the rope-ladder technique. https://app.cochat.ai/papers/10.1093/ndt/gfp420
The paper
van Loon, M. M., Goovaerts, T., Kessels, A. G. H., van der Sande, F. M., & Tordoir, J. H. M. (2010). Buttonhole needling of haemodialysis arteriovenous fistulae results in less complications and interventions compared to the rope-ladder technique. Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/gfp420

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.