CoChat

Reproducibility of albuminuria in type 2 diabetic subjects. Findings from the Renal Insufficiency And Cardiovascular Events (RIACE) study

Pugliese, Giuseppe, Solini, Anna, Fondelli, Cecilia, Trevisan, Roberto, Vedovato, Monica, Nicolucci, Antonio, Penno, Giuseppe · 2011 · Nephrology Dialysis Transplantation
Cited by 93

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Measurement of urinary albumin excretion (UAE) shows important intra-individual variability suggesting the need for multiple assessments. This study aimed at investigating the reproducibility of UAE in type 2 diabetes. METHODS: UAE was obtained from two to three samples collected in a 3- to 6-month period from 4062 of the 15 773 type 2 diabetic subjects participating in the Renal Insufficiency And Cardiovascular Events (RIACE) Italian Multicentre Study in 2007-08. UAE was assessed as albumin excretion rate (AER) in 24-h urine collections from 833 subjects and albumin:creatinine ratio (A/C) in early-morning urine samples from 3229 patients. Albuminuria was measured by immunonephelometry or immunoturbidimetry. RESULTS: The median coefficient of variation (CV) was 32.5% (interquartile range: 14.3-58.9). Concordance rate between a single UAE and the geometric mean of multiple measurements was 94.6% for normoalbuminuria, 83.5% for microalbuminuria, 91.1% for macroalbuminuria and 90.6% for albuminuria (micro + macro). CV was significantly higher (P < 0.01) for AER measurement than for A/C and with immunoturbidimetry than with immunonephelometry, whereas concordance rates were similar between the two modalities of urine collection and the two assay methods. Receiver-operating characteristic (ROC) plots demonstrated a good performance of single UAE in predicting the geometric mean of multiple measures at the cut-off level of both microalbuminuria (ROC(AUC) 0.926; 95% confidence interval: 0.915-0.937) and macroalbuminuria (ROC(AUC) 0.950; 95% confidence interval: 0.927-0.973). CONCLUSIONS: Data from this large cohort indicate that, in type 2 diabetic subjects, a single UAE value, thought to be encumbered with high intra-individual variability, is an accurate predictor of nephropathy stage for clinical and epidemiological purposes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ndt/gfr140

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 93

Metadata

Authors
Pugliese, G., Solini, A., Fondelli, C., Trevisan, R., Vedovato, M., Nicolucci, A., & Penno, G.
Venue
Nephrology Dialysis Transplantation
Published
2011-03-25
Volume
26
Issue
12
Pages
3950-3954
ISSN
  • 0931-0509 (ISSN-L)
  • 1460-2385
OpenAlex
W2148419865
Cited by
93
References
5
FWCI
5.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reproducibility of albuminuria in type 2 diabetic subjects. Findings from the Renal Insufficiency And Cardiovascular Events (RIACE) study. https://app.cochat.ai/papers/10.1093/ndt/gfr140
The paper
Pugliese, G., Solini, A., Fondelli, C., Trevisan, R., Vedovato, M., Nicolucci, A., & Penno, G. (2011). Reproducibility of albuminuria in type 2 diabetic subjects. Findings from the Renal Insufficiency And Cardiovascular Events (RIACE) study. Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/gfr140

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.