Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 183

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Performance of18F-FET versus18F-FDG-PET for the diagnosis and grading of brain tumors: systematic review and meta-analysis

Open access
Dunet, Vincent, Pomoni, Anastasia, Hottinger, Andreas, Nicod-Lalonde, Marie, Prior, John O. · 2016 · Neuro-Oncology

Abstract

BACKGROUND: For the past decade (18)F-fluoro-ethyl-l-tyrosine (FET) and (18)F-fluoro-deoxy-glucose (FDG) positron emission tomography (PET) have been used for the assessment of patients with brain tumor. However, direct comparison studies reported only limited numbers of patients. Our purpose was to compare the diagnostic performance of FET and FDG-PET. METHODS: We examined studies published between January 1995 and January 2015 in the PubMed database. To be included the study should: (i) use FET and FDG-PET for the assessment of patients with isolated brain lesion and (ii) use histology as the gold standard. Analysis was performed on a per patient basis. Study quality was assessed with STARD and QUADAS criteria. RESULTS: Five studies (119 patients) were included. For the diagnosis of brain tumor, FET-PET demonstrated a pooled sensitivity of 0.94 (95% CI: 0.79-0.98) and pooled specificity of 0.88 (95% CI: 0.37-0.99), with an area under the curve of 0.96 (95% CI: 0.94-0.97), a positive likelihood ratio (LR+) of 8.1 (95% CI: 0.8-80.6), and a negative likelihood ratio (LR-) of 0.07 (95% CI: 0.02-0.30), while FDG-PET demonstrated a sensitivity of 0.38 (95% CI: 0.27-0.50) and specificity of 0.86 (95% CI: 0.31-0.99), with an area under the curve of 0.40 (95% CI: 0.36-0.44), an LR+ of 2.7 (95% CI: 0.3-27.8), and an LR- of 0.72 (95% CI: 0.47-1.11). Target-to-background ratios of either FDG or FET, however, allow distinction between low- and high-grade gliomas (P > .11). CONCLUSIONS: For brain tumor diagnosis, FET-PET performed much better than FDG and should be preferred when assessing a new isolated brain tumor. For glioma grading, however, both tracers showed similar performances.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/neuonc/nov148

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 183

Metadata

Authors
Dunet, V., Pomoni, A., Hottinger, A., Nicod-Lalonde, M., & Prior, J. O.
Venue
Neuro-Oncology
Published
2015-08-04
Volume
18
Issue
3
Pages
426-434
ISSN
  • 1522-8517 (ISSN-L)
  • 1523-5866
OpenAlex
W2113122028
Cited by
183
References
3
FWCI
3.37
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance of18F-FET versus18F-FDG-PET for the diagnosis and grading of brain tumors: systematic review and meta-analysis. https://app.cochat.ai/papers/10.1093/neuonc/nov148
The paper
Dunet, V., Pomoni, A., Hottinger, A., Nicod-Lalonde, M., & Prior, J. O. (2016). Performance of18F-FET versus18F-FDG-PET for the diagnosis and grading of brain tumors: systematic review and meta-analysis. Neuro-Oncology. https://doi.org/10.1093/neuonc/nov148

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.