SonoWand, an Ultrasound-based Neuronavigation System
The DOI matches its OpenAlex record.
Abstract
OBJECTIVE: We have integrated a neuronavigation system into an ultrasound scanner and developed a single-rack system that enables the surgeon to perform frameless and armless stereotactic neuronavigation using intraoperative three-dimensional ultrasound data as well as preoperative magnetic resonance or computed tomographic images. The purpose of this article is to describe our two-rack prototype and present the results of our work on image quality enhancement. DESCRIPTION OF INSTRUMENTATION: The system consists of a high-end ultrasound scanner, a modest-cost computer, and an optical positioning/digitizer system. Special technical and clinical efforts have been made to achieve high image quality. A special interface between the ultrasound instrument and the navigation computer ensures rapid transfer of digital three-dimensional data with no loss of image quality. OPERATIVE TECHNIQUE: The positioning system tracks the position and orientation of the patient, the ultrasound probe, the pointer, and various surgical instruments. This makes it possible to update the three-dimensional map during surgery and navigate by ultrasound data in a similar manner as with magnetic resonance data. METHODS: The two-rack prototype has been used for clinical testing since November 1997 at the University Hospital in Trondheim. EXPERIENCE AND RESULTS: The image quality improvements have enabled us, in most cases, to extract information from ultrasound with clinical value similar to that of preoperative magnetic resonance imaging. The overall clinical accuracy of the ultrasound-based navigation system is expected to be comparable to or better than that of a magnetic resonance imaging-based system. CONCLUSION: The SonoWand system enables neuronavigation through direct use of intraoperative three-dimensional ultrasound. Further research will be necessary to explore the potential clinical value and the limitations of this technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Jakola, A. S., Myrmel, K. S., Kloster, R., Torp, S. H., Lindal, S., Unsgård, G., & Solheim, O. (2012) · JAMA · doi:10.1001/jama.2012.12807 · Cited by 641
Self-citationA review of calibration techniques for freehand 3-D ultrasound systems
Mercier, L., Langø, T., Lindseth, F., & Collins, D. L. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.11.015 · Cited by 326
Self-citationUnsgaard, G., Ommedal, S., Muller, T., Gronningsaeter, A., & Nagelhus Hernes, T. A. (2002) · Neurosurgery · doi:10.1097/00006123-200204000-00022 · Cited by 262
Self-citationIntra-operative 3D ultrasound in neurosurgery
Unsgaard, G., Rygh, O. M., Selbekk, T., Müller, T. B., Kolstad, F., Lindseth, F., & Hernes, T. A. N. (2006) · Acta Neurochirurgica · doi:10.1007/s00701-005-0688-y · Cited by 252
Self-citationFreehand 3D Ultrasound Reconstruction Algorithms—A Review
Solberg, O. V., Lindseth, F., Torp, H., Blake, R. E., & Nagelhus Hernes, T. A. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.02.015 · Cited by 220
Self-citationImage-to-patient registration techniques in head surgery
Eggers, G., Mühling, J., & Marmulla, R. (2006) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2006.09.015 · Cited by 214
Reinges, M. H. T., Nguyen, H.-H., Krings, T., H�tter, B.-O., Rohde, V., & Gilsbach, J. M. (2004) · Acta Neurochirurgica · doi:10.1007/s00701-003-0204-1 · Cited by 200
Applications of Ultrasound in the Resection of Brain Tumors
Sastry, R., Bi, W. L., Pieper, S., Frisken, S., Kapur, T., Wells, W., & Golby, A. J. (2017) · Journal of Neuroimaging · doi:10.1111/jon.12382 · Cited by 167
Rasmussen, I.-A., Lindseth, F., Rygh, O. M., Berntsen, E. M., Selbekk, T., Xu, J., Nagelhus Hernes, T. A., Harg, E., Håberg, A., & Unsgaard, G. (2007) · Acta Neurochirurgica · doi:10.1007/s00701-006-1110-0 · Cited by 163
Self-citationFreehand 3-D Ultrasound Imaging: A Systematic Review
Mozaffari, M. H., & Lee, W.-S. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.06.009 · Cited by 159
Metadata
- Authors
- Grønningsaeter, A., Kleven, A., Ommedal, S., Aarseth, T. E., Lie, T., Lindseth, F., Langø, T., & Unsgård, G.
- Venue
- Neurosurgery
- Publisher
- Lippincott Williams & Wilkins
- Published
- 2000-12-01
- Volume
- 47
- Issue
- 6
- Pages
- 1373-1380
- ISSN
- 0148-396X (ISSN-L)
- OpenAlex
- W2052508160
- Cited by
- 213
- References
- 0
- FWCI
- 16.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.