Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 262

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Neuronavigation by Intraoperative Three-dimensional Ultrasound: Initial Experience during Brain Tumor Resection

Unsgaard, Geirmund, Ommedal, Steinar, Muller, Tomm, Gronningsaeter, Aage, Nagelhus Hernes, Toril A.·2002·Neurosurgery

Abstract

OBJECTIVE: Three-dimensional (3-D) ultrasound is an intraoperative imaging modality used in neuronavigation as an alternative to magnetic resonance imaging (MRI). This article summarizes 4 years of clinical experience in the use of intraoperative 3-D ultrasound integrated into neuronavigation for guidance in brain tumor resection. METHODS: Patients were selected for inclusion in the study on the basis of the size and location of their lesion. Preoperative 3-D MRI data were registered and used for planning as in other conventional neuronavigation systems. Intraoperative 3-D ultrasound images were acquired three to six times, and tumor resection was guided on the basis of these updated 3-D images. RESULTS: Intraoperative 3-D ultrasound represents a good solution to the problem of brain shift in neuronavigation because it easily provides an updated, and hence more accurate, map of the patient's true anatomy in all phases of the operation. Ultrasound makes it possible to follow the progression of the operation, and it improves the radicality of tumor resection by detecting tumor tissue that would remain if the imaging technology had not been used (in 53% of the cases). Integration of 3-D ultrasound with navigation technology solves the orientation problem experienced previously with two-dimensional ultrasound in neurosurgery. The technology makes it possible to directly compare intraoperative ultrasound and MRI data regarding visualization of the lesion. Ultrasound image quality is useful for guiding surgical procedures. CONCLUSION: Intraoperative 3-D ultrasound seems to provide a time- and cost-effective way to update high-quality 3-D maps used in neuronavigation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00006123-200204000-00022

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 262

Metadata

Authors
Unsgaard, G., Ommedal, S., Muller, T., Gronningsaeter, A., & Nagelhus Hernes, T. A.
Venue
Neurosurgery
Published
2002-04-01
Volume
50
Issue
4
Pages
804-812
ISSN
  • 0148-396X (ISSN-L)
  • 1524-4040
OpenAlex
W2086031785
Cited by
262
References
16
FWCI
7.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Neuronavigation by Intraoperative Three-dimensional Ultrasound: Initial Experience during Brain Tumor Resection. https://app.cochat.ai/papers/10.1097/00006123-200204000-00022
The paper
Unsgaard, G., Ommedal, S., Muller, T., Gronningsaeter, A., & Nagelhus Hernes, T. A. (2002). Neuronavigation by Intraoperative Three-dimensional Ultrasound: Initial Experience during Brain Tumor Resection. Neurosurgery. https://doi.org/10.1097/00006123-200204000-00022

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.