Cited by 19Infection Control in HealthcareOccupational Health and Safety in WorkplacesTextile materials and evaluations

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Comparison of blood transmission through latex and nitrile glove materials

Mansouri, M., Tidley, M., Sanati, K. A., Roberts, C.·2010·Occupational Medicine

Abstract

AIMS: To compare blood transmission through nitrile, single and double layer latex glove materials in simulated needlestick injuries. METHODS: Experiments involved nitrile, single and double layer latex gloves. A cutting suture needle was dipped into a specimen of blood and then immediately jabbed through the glove material into a cell containing saline. This process was repeated using the same blood specimen with different glove materials, plus a control experiment with no glove material. Other factors, including the angle, speed and depth of needle penetration, were controlled through the use of a testing machine. Following needle punctures, samples were taken from the suspension contained in each cell and examined under blind conditions. Median red blood cell (RBC) count was used as a measure of the quantities of blood transmitted through the different gloves. RESULTS: Nitrile glove material was associated with reduced transmission of RBCs compared to single layer latex. Double layer latex gloves provided better protection than single layer latex or nitrile gloves. CONCLUSIONS: These findings suggest that in protecting against blood transmission in the context of needlestick injuries, single layer nitrile gloves are superior to single layer latex gloves, but double gloving with latex gloves provides better protection than either single layer latex or nitrile.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/occmed/kqp196

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The risk of blood contact and contamination during venous blood sampling is reduced using gloves.

    “There is evidence showing that this risk is reduced using gloves [45], [46].”

    From Joint EFLM-COLABIOCLI Recommendation for venous blood sampling (2018) · cites this paper as [45]

    The Results (p. 4) report that all tested glove materials significantly reduced blood transfer compared with no glove. However, the Methods (p. 1) describe simulated needlestick injuries, not venous blood sampling; the paper does not establish a reduced risk of blood contact and contamination during that procedure. (LLM, conf=0.88)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Metadata

Authors
Mansouri, M., Tidley, M., Sanati, K. A., & Roberts, C.
Affiliations
  • Princess of Wales Hospital (GB)
  • King's College Hospital NHS Foundation Trust (GB)
  • University of Manchester (GB)
Venue
Occupational Medicine
Published
2010-01-22
Volume
60
Issue
3
Pages
205-210
ISSN
  • 0962-7480 (ISSN-L)
  • 1471-8405
OpenAlex
W2117199683
Cited by
19
References
15
Citations by year
2025: 1 · 2024: 1 · 2021: 2 · 2020: 1 · 2019: 5 · 2018: 1 · 2017: 1 · 2016: 2 · 2014: 1 · 2013: 2 · 2012: 1
FWCI
0.83
Type
journal article
Language
en
Open access
closed
Locations
  • Occupational Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • Research Explorer (The University of Manchester) (submittedVersion)
Topics
  • Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
  • Physical Sciences › Materials Science › Polymers and Plastics › Textile materials and evaluations
Keywords
needlestick injuries, blood transmission, nitrile gloves, latex gloves, double gloving, glove material comparison, red blood cell count, occupational exposure to blood
MeSH terms
Cell Count, Equipment Design, Erythrocytes, Gloves, Surgical, Health Personnel, Humans, Latex, Materials Testing, Nitriles, Occupational Exposure, Needlestick Injuries, Infectious Disease Transmission, Patient-to-Professional, Statistics, Nonparametric

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review