Dynamic Light Scattering: The method and some applications
The DOI matches its Crossref record.
Abstract
Dynamic light scattering is a new method for investigating macromolecular systems. The importance of the technique lies in its non-invasive character. It can be employed on extremely small fluid volumes, the instrumentation is relatively inexpensive and allows the rapid determination of diffusion coefficients as well as providing information on relaxation time distributions for the macromolecular components of complex systems. This volume is directed in part to the philosophy and current practice in dynamic light scattering: single photon correlation techniques are introduced, a discussion of noise on photon correlation functions is given and data analysis in dynamic light scattering to polymer structure analysis is presented and a comprehensive introduction to diffusing wave spectroscopy is given. Theoretical developments relating dynamic light scattering to the viscoelasticity of polymers in solution and in the bulk are described. The second aim is to illustrate the widely varying fields in which the technique finds application. Chapters are to be found on multicomponent mixtures, polyelectrolytes, dense polymer systems, gels, rigid rods, micellar systems and the application of dynamic light scattering to biological systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanoparticle PEGylation for Imaging and Therapy
Jokerst, J. V., Lobovkina, T., Zare, R. N., & Gambhir, S. S. (2011) · Nanomedicine · doi:10.2217/nnm.11.19 · Cited by 2,046
Optical Measurements of Frequency-Dependent Linear Viscoelastic Moduli of Complex Fluids
Mason, T. G., & Weitz, D. A. (1995) · Physical Review Letters · doi:10.1103/physrevlett.74.1250 · Cited by 1,672
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Takahashi, K., & Sakurai, K. (2020) · Drug Delivery System · doi:10.2745/dds.35.332 · Cited by 917
Particle Tracking Microrheology of Complex Fluids
Mason, T. G., Ganesan, K., van Zanten, J. H., Wirtz, D., & Kuo, S. C. (1997) · Physical Review Letters · doi:10.1103/physrevlett.79.3282 · Cited by 879
Lombardo, D., & Kiselev, M. A. (2022) · Pharmaceutics · doi:10.3390/pharmaceutics14030543 · Cited by 718
Baruah, B., Gabriel, G. J., Akbashev, M. J., & Booher, M. E. (2013) · Langmuir · doi:10.1021/la305068p · Cited by 391
Yu, J., Javier, D., Yaseen, M. A., Nitin, N., Richards-Kortum, R., Anvari, B., & Wong, M. S. (2010) · Journal of the American Chemical Society · doi:10.1021/ja908139y · Cited by 312
Percec, V., Ahn, C.-H., Cho, W.-D., Jamieson, A. M., Kim, J., Leman, T., Schmidt, M., Gerle, M., Möller, M., Prokhorova, S. A., et al. (1998) · Journal of the American Chemical Society · doi:10.1021/ja981211v · Cited by 309
Yadav, S., Laue, T. M., Kalonia, D. S., Singh, S. N., & Shire, S. J. (2012) · Molecular Pharmaceutics · doi:10.1021/mp200566k · Cited by 280
On measuring colloidal volume fractions
Poon, W. C. K., Weeks, E. R., & Royall, C. P. (2012) · Soft Matter · doi:10.1039/c1sm06083j · Cited by 216
Köping‐Höggård, M., Mel'nikova, Y. S., Vårum, K. M., Lindman, B., & Artursson, P. (2003) · The Journal of Gene Medicine · doi:10.1002/jgm.327 · Cited by 212
Sehgal, A., Lalatonne, Y., Berret, J.-F., & Morvan, M. (2005) · Langmuir · doi:10.1021/la0513757 · Cited by 210
Hyun, B.-R., Dzyuba, S. V., Bartsch, R. A., & Quitevis, E. L. (2002) · The Journal of Physical Chemistry A · doi:10.1021/jp0141575 · Cited by 201
The analysis of solution self-assembled polymeric nanomaterials
Patterson, J. P., Robin, M. P., Chassenieux, C., Colombani, O., & O'Reilly, R. K. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60454c · Cited by 195
Oh, E., Susumu, K., Goswami, R., & Mattoussi, H. (2010) · Langmuir · doi:10.1021/la904438s · Cited by 173
Bantz, C., Koshkina, O., Lang, T., Galla, H.-J., Kirkpatrick, C. J., Stauber, R. H., & Maskos, M. (2014) · Beilstein Journal of Nanotechnology · doi:10.3762/bjnano.5.188 · Cited by 166
Giacomelli, C., Le Men, L., Borsali, R., Lai-Kee-Him, J., Brisson, A., Armes, S. P., & Lewis, A. L. (2006) · Biomacromolecules · doi:10.1021/bm0508921 · Cited by 160
Microrheology of cross-linked polyacrylamide networks
Dasgupta, B. R., & Weitz, D. A. (2005) · Physical Review E · doi:10.1103/physreve.71.021504 · Cited by 158
Biogenesis, Isolation, and Detection of Exosomes and Their Potential in Therapeutics and Diagnostics
Sonbhadra, S., Mehak, & Pandey, L. M. (2023) · Biosensors · doi:10.3390/bios13080802 · Cited by 97
Lee, H.-N., Bai, Z., Newell, N., & Lodge, T. P. (2010) · Macromolecules · doi:10.1021/ma1019279 · Cited by 89
Metadata
- Publisher
- Oxford University PressOxford
- Published
- 1993-01-28
- OpenAlex
- W4388247015
- Cited by
- 763
- References
- 0
- FWCI
- 5.26
- Type
- book
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.