The DOI matches its Crossref record.
Association of Indoor Nitrogen Dioxide with Respiratory Symptoms and Pulmonary Function in Children
Abstract
The effect of indoor nitrogen dioxide on the cumulative incidence of respiratory symptoms and pulmonary function level was studied in a cohort of 1,567 white children aged 7-11 years examined in six US cities from 1983 through 1988. Week-long measurements of nitrogen dioxide were obtained at three indoor locations over 2 consecutive weeks in both the winter and the summer months. The household annual average nitrogen dioxide concentration was modeled as a continuous variable and as four ordered categories. Multiple logistic regression analysis of symptom reports from a questionnaire administered after indoor monitoring showed that a 15-ppb increase in the household annual nitrogen dioxide mean was associated with an increased cumulative incidence of lower respiratory symptoms (odds ratio (OR) = 1.4, 95% confidence interval (95% Cl) 1.1-1.7). The response variable indicated the report of one or more of the following symptoms: attacks of shortness of breath with wheeze, chronic wheeze, chronic cough, chronic phlegm, or bronchitis. Girls showed a stronger association (OR = 1.7, 95% Cl 1.3-2.2) than did boys (OR = 1.2, 95% Cl 0.9-1.5). An analysis of pulmonary function measurements showed no consistent effect of nitrogen dioxide. These results are consistent with earlier reports based on categorical indicators of household nitrogen dioxide sources and provide a more specific association with nitrogen dioxide as measured in children's homes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Effects of Ambient Air Pollution on School Absenteeism Due to Respiratory Illnesses
Gilliland, F. D., Berhane, K., Rappaport, E. B., Thomas, D. C., Avol, E., Gauderman, W. J., London, S. J., Margolis, H. G., McConnell, R., Islam, K. T., et al. (2001) · Epidemiology · doi:10.1097/00001648-200101000-00009 · Cited by 266
Self-reported wheezing and allergic rhinitis in children and traffic density on street of residence
Weiland, S. K., Mundt, K. A., Rückmann, A., & Keil, U. (1994) · Annals of Epidemiology · doi:10.1016/1047-2797(94)90103-1 · Cited by 254
Ventilation in public housing: implications for indoor nitrogen dioxide concentrations
Zota, A., Adamkiewicz, G., Levy, J. I., & Spengler, J. D. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2005.00375.x · Cited by 118
Self-citationThe respiratory health effects of nitrogen dioxide in children with asthma
Gillespie-Bennett, J., Pierse, N., Wickens, K., Crane, J., Howden-Chapman, P., & and the Housing Heating and Health Study Research Team (2011) · European Respiratory Journal · doi:10.1183/09031936.00115409 · Cited by 98
Effects of Indoor Environmental Factors on Respiratory Health of Children in a Subtropical Climate
Yang, C.-Y., Chiu, J.-F., Cheng, M.-F., & Lin, M.-C. (1997) · Environmental Research · doi:10.1006/enrs.1997.3774 · Cited by 73
Metadata
- Authors
- Neas, L. M., Dockery, D. W., Ware, J. H., Spengler, J. D., Speizer, F. E., & Ferris, B. G.
- Venue
- American Journal of Epidemiology
- Publisher
- Oxford University Press (OUP)
- Published
- 1991-07-15
- Volume
- 134
- Issue
- 2
- Pages
- 204-219
- ISSN
- 0002-9262 (ISSN-L)
- 1476-6256
- OpenAlex
- W1945160720
- Cited by
- 221
- References
- 0
- FWCI
- 10.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Association of Indoor Nitrogen Dioxide with Respiratory Symptoms and Pulmonary Function in Children. https://app.cochat.ai/papers/10.1093/oxfordjournals.aje.a116073
- The paper
- Neas, L. M., Dockery, D. W., Ware, J. H., Spengler, J. D., Speizer, F. E., & Ferris, B. G. (1991). Association of Indoor Nitrogen Dioxide with Respiratory Symptoms and Pulmonary Function in Children. American Journal of Epidemiology. https://doi.org/10.1093/oxfordjournals.aje.a116073
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.