The DOI matches its Crossref record.
Nitrous Oxide and Spontaneous Abortion in Female Dental Assistants
Abstract
The relation between anesthetic gas exposure and spontaneous abortion remains unresolved. We examined the effect of nitrous oxide on spontaneous abortion among female dental assistants. Questionnaires were sent to 7,000 dental assistants aged 18-39 years who were registered in California in 1987; 4,856 (69%) responded. Analysis was based on 1,465 respondents whose most recent pregnancy was conceived while working full time. Women were asked how many hours a week they worked with nitrous oxide during this pregnancy and whether the excess gas was scavenged (vented). Relative risk of spontaneous abortion (through week 20) was calculated using a person-week model. This allowed women with current pregnancies (13%) or induced abortions (10%) to be included for appropriate time periods of risk. A total of 101 pregnancies (7%) ended as spontaneous abortions. An elevation in risk of spontaneous abortion was seen among women who worked with nitrous oxide for 3 or more hours per week in offices not using scavenging equipment (relative risk = 2.6, 95% confidence interval 1.3-5.0, adjusted for age, smoking, and number of amalgams prepared per week), but not among those using nitrous oxide in offices with scavenging equipment. This relation changed little when analyses were restricted to confirmed pregnancies or examined for several types of potential bias. Scavenging equipment appears to be important in protecting the reproductive health of women working with nitrous oxide.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Procedural sedation and analgesia in children
Krauss, B., & Green, S. M. (2006) · The Lancet · doi:10.1016/s0140-6736(06)68230-5 · Cited by 564
Biologic Effects of Nitrous Oxide: A Mechanistic and Toxicologic Review
Sanders, R. D., Weimann, J., Maze, M., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e3181870a17 · Cited by 366
Update on Bispectral Index monitoring
Johansen, J. W. (2006) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2005.08.004 · Cited by 313
Romero, L. M., & Remage-Healey, L. (2000) · General and Comparative Endocrinology · doi:10.1006/gcen.2000.7491 · Cited by 259
Folate, Vitamin B12 and Homocysteine in Relation to Birth Defects and Pregnancy Outcome
Refsum, H. (2001) · British Journal of Nutrition · doi:10.1079/bjn2000302 · Cited by 180
Metadata
- Authors
- Rowland, A. S., Baird, D. D., Shore, D. L., Weinberg, C. R., Savitz, D. A., & Wilcox, A. J.
- Venue
- American Journal of Epidemiology
- Publisher
- Oxford University Press (OUP)
- Published
- 1995-03-15
- Volume
- 141
- Issue
- 6
- Pages
- 531-538
- ISSN
- 0002-9262 (ISSN-L)
- 1476-6256
- OpenAlex
- W1900494680
- Cited by
- 270
- References
- 0
- FWCI
- 25.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nitrous Oxide and Spontaneous Abortion in Female Dental Assistants. https://app.cochat.ai/papers/10.1093/oxfordjournals.aje.a117468
- The paper
- Rowland, A. S., Baird, D. D., Shore, D. L., Weinberg, C. R., Savitz, D. A., & Wilcox, A. J. (1995). Nitrous Oxide and Spontaneous Abortion in Female Dental Assistants. American Journal of Epidemiology. https://doi.org/10.1093/oxfordjournals.aje.a117468
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.