The DOI matches its Crossref record.
The principles of magnetic resonance
Abstract
Magnetic Resonance (MR), which has no known biological hazard, is capable of producing high resolution thin tomographic images in any plane and blocks of 3-dimensional information. It can be used to study blood flow and to gain information about the composition of important materials seen and quantified on dimensionally accurate images. The MR image is a thin tomographic slice or a true three dimensional block of data which can be reconstructed in any desired way rather than a shadowgram of all the structures in the beam. It is the only imaging technique which can acquire data in a 3-dimensional format. CT images can be reconstructed to form a pseudo 3-D image or a hologram but the flexibility conferred by acquiring the data as a true 3-D block gives many advantages. The spatial resolution of MR images are theoretically those of low powered microscopy, the practical limits with the present generation of equipment are voxel sizes of one third by one third by two millimetres. The term Magnetic Resonance Imaging (MRI) is used commonly, particularly in the USA, avoiding association with the term, nuclear, and emphasizing the imaging potential of the technique. The terms Nuclear Magnetic Resonance (NMR) or Magnetic Resonance (MR) more correctly describe the most powerful diagnostic instrument yet devised. The simplified description of the phenomena involved in MR which follows is intended to be comprehensive and does not require foreknowledge of classical physics, quantum mechanics, fluency with mathematical formulae or an understanding of image reconstruction. There are many explanations of MR, some omitting the more difficult concepts. An accurate, comprehensive description is found on the textbook on MR by Gadian, Nuclear Magnetic Resonance and its Applications for Living Systems (Oxford University Press, 1982).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Experimental Quantum Error Correction
Cory, D. G., Price, M. D., Maas, W., Knill, E., Laflamme, R., Zurek, W. H., Havel, T. F., & Somaroo, S. S. (1998) · Physical Review Letters · doi:10.1103/physrevlett.81.2152 · Cited by 581
Kinetics of Cross-Polarization in Solid-State NMR: A Guide for Chemists
Kolodziejski, W., & Klinowski, J. (2002) · Chemical Reviews · doi:10.1021/cr000060n · Cited by 484
Qudits and High-Dimensional Quantum Computing
Wang, Y., Hu, Z., Sanders, B. C., & Kais, S. (2020) · Frontiers in Physics · doi:10.3389/fphy.2020.589504 · Cited by 478
Theory of Dilute Magnetic Alloys
Kondo, J. (1970) · Solid State Physics · doi:10.1016/s0081-1947(08)60616-5 · Cited by 278
Electronic Structure: Basic Theory and Practical Methods
Martin, R. M. (2020) · Cambridge University Press eBooks · doi:10.1017/9781108555586 · Cited by 269
Metadata
- Authors
- Longmore, D. B.
- Venue
- British Medical Bulletin
- Publisher
- Oxford University Press (OUP)
- Published
- 1989-10
- Volume
- 45
- Issue
- 4
- Pages
- 848-880
- ISSN
- 0007-1420 (ISSN-L)
- 1471-8391
- OpenAlex
- W2401877568
- Cited by
- 264
- References
- 0
- FWCI
- 10.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The principles of magnetic resonance. https://app.cochat.ai/papers/10.1093/oxfordjournals.bmb.a072371
- The paper
- Longmore, D. B. (1989). The principles of magnetic resonance. British Medical Bulletin. https://doi.org/10.1093/oxfordjournals.bmb.a072371
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.