CoChat

Angiotensin II-receptor subtypes in human atria and evidence for alterations in patients with cardiac dysfunction

Rogg, H., de Gasparo, M., Graedel, E., Stulz, P., Burkart, F., Eberhard, M., Erne, P. · 1996 · European Heart Journal
Cited by 95

The DOI matches its Crossref record.

Abstract

Angiotensin II (AII) has been implicated as an important factor in the pathophysiology of heart diseases. Following the recent identification of two subtypes of the AII receptor in cardiac tissue of animals, we investigated the possible occurrence of these, or similar, subtypes in human atrial tissue. In right-atrial tissue from patients undergoing heart surgery, we determined the AII-receptor profile in receptor binding studies, using [125I]-angiotensin as radioligand and subtypes to identify and quantify AII-receptor subpopulations. In 35 patients (23 requiring coronary bypasses, 10 valvular surgery and two combined coronary and valvular surgery), the left-ventricular ejection fraction was determined in the preoperative phase, and right- and left-atrial pressure during surgery. In membranes of human right atria, AII receptors are present in high density (median: Bmax = 294 fmol.mg-1 protein, range: 111-2073) and two different subtypes can be distinguished. Type-1 receptors (AT1) accounted for 33 +/- 10% of the population whereas type-2 receptors (AT2) made up 67 +/- 10% of the population. There was no correlation between any of the measured cardiac functions and total AII-receptor density or receptor affinity. However, the percentage of AT1 receptors was higher in the atria of patients with normal right-atrial pressure; left-ventricular ejection fraction was positively and right-atrial pressure inversely correlated with the percentage of AT1 receptors (r = 0.740 and -0.901, respectively; P < 0.001, for both). Moreover, the percentage of AT2 receptors was directly correlated with the levels of left-atrial pressure (r = 0.853; P < 0.001). It is concluded that the ratio of AT1 to AT2 receptors correlates well with right-atrial pressure and left-ventricular function. This is a first indication of a possible involvement of AII-receptor subtypes in the pathophysiology of cardiac dysfunctions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/oxfordjournals.eurheartj.a015008

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 95

Metadata

Authors
Rogg, H., de Gasparo, M., Graedel, E., Stulz, P., Burkart, F., Eberhard, M., & Erne, P.
Venue
European Heart Journal
Published
1996-07-01
Volume
17
Issue
7
Pages
1112-1120
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W1974279158
Cited by
95
References
0
FWCI
9.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Angiotensin II-receptor subtypes in human atria and evidence for alterations in patients with cardiac dysfunction. https://app.cochat.ai/papers/10.1093/oxfordjournals.eurheartj.a015008
The paper
Rogg, H., de Gasparo, M., Graedel, E., Stulz, P., Burkart, F., Eberhard, M., & Erne, P. (1996). Angiotensin II-receptor subtypes in human atria and evidence for alterations in patients with cardiac dysfunction. European Heart Journal. https://doi.org/10.1093/oxfordjournals.eurheartj.a015008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.