Inter-study variability in left ventricular mass measurement Comparison between M-mode echography and MRI
The DOI matches its Crossref record.
Abstract
In order to compare variability in M-mode echography and MRI in the assessment of left ventricular mass, 20 echogenic patients without evidence of coronary artery disease were investigated. Two MR and two M-echo examinations were performed within 4 days by different trained operators, each unaware of the other's results. M-mode echo was carried out according to Devereux's method, using the 'Penn-Cube' formula. MR protocol included multislice (8 to 12) true, short-axis spin-echo imaging (10 mm thick with a 1 to 3 mm gap) encompassing the entire left ventricle. Planimetry was manually traced with standardized window settings. Correlations between both echographic and both MR measurements showed r = 0.89, SEE = 22.7 g and r = 0.96, SEE = 11.2 g, respectively. Mean inter-study variability was 11 +/- 6.4% and 6.75 +/- 3.8% (P = 0.0021). The threshold value corresponding to the 95th percentile of the variability data was 21.5% for echography and 13.5% for MR. In conclusion, MR appeared to be a significantly more reproducible examination tool, when compared with M-mode echo, for the evaluation of left ventricular mass (variability, 63% higher with echo than with MR). The main practical consequence of this result lies in the reduced number of patients required to demonstrate a significant change in the LVM with MR as compared with echography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bellenger, N. (2000) · European Heart Journal · doi:10.1053/euhj.2000.2011 · Cited by 1,040
Cheitlin, M. D., Alpert, J. S., Armstrong, W. F., Aurigemma, G. P., Beller, G. A., Bierman, F. Z., Davidson, T. W., Davis, J. L., Douglas, P. S., Gillam, L. D., et al. (1997) · Circulation · doi:10.1161/01.cir.95.6.1686 · Cited by 831
Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report?
PENNELL, D. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.040 · Cited by 747
Alfakih, K., Plein, S., Thiele, H., Jones, T., Ridgway, J. P., & Sivananthan, M. U. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10262 · Cited by 732
Cardiac atrophy after bed rest and spaceflight
Perhonen, M. A., Franco, F., Lane, L. D., Buckey, J. C., Blomqvist, C. G., Zerwekh, J. E., Peshock, R. M., Weatherall, P. T., & Levine, B. D. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.2.645 · Cited by 494
Metadata
- Authors
- GERMAIN, P., ROUL, G., KASTLER, B., MOSSARD, J.-M., BAREISS, P., & SACREZ, A.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-08
- Volume
- 13
- Issue
- 8
- Pages
- 1011-1019
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2174628707
- Cited by
- 132
- References
- 0
- FWCI
- 1.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inter-study variability in left ventricular mass measurement Comparison between M-mode echography and MRI. https://app.cochat.ai/papers/10.1093/oxfordjournals.eurheartj.a060307
- The paper
- GERMAIN, P., ROUL, G., KASTLER, B., MOSSARD, J.-M., BAREISS, P., & SACREZ, A. (1992). Inter-study variability in left ventricular mass measurement Comparison between M-mode echography and MRI. European Heart Journal. https://doi.org/10.1093/oxfordjournals.eurheartj.a060307
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.