Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 732

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady‐state free precession imaging sequences

Open access
Alfakih, Khaled, Plein, Sven, Thiele, Holger, Jones, Tim, Ridgway, John P., Sivananthan, Mohan U.·2003·Journal of Magnetic Resonance Imaging

Abstract

Purpose: To establish normal ranges of left ventricular (LV) and right ventricular (RV) dimensions as determined by the current pulse sequences in cardiac magnetic resonance imaging (MRI). Materials and Methods: Sixty normal subjects (30 male and 30 female; age range, 20–65) were examined; both turbo gradient echo (TGE) and steady‐state free precession (SSFP) pulse sequences were used to obtain contiguous short‐axis cine data sets from the ventricular apex to the base of the heart. The LV and RV volumes and LV mass were calculated by modified Simpson's rule. Results: Normal ranges were established and indexed to both body surface area (BSA) and height. There were statistically significant differences in the measurements between the genders and between TGE and SSFP pulse sequences. For TGE the LV end‐diastolic volume (EDV)/BSA (mL/m 2) in males was 74.4 ± 14.6 and in females was 70.9 ± 11.7, while in SSFP in males it was 82.3 ± 14.7 and in females it was 77.7 ± 10.8. For the TGE the LV mass/BSA (g/m 2) in males was 77.8 ± 9.1 and in females it was 61.5 ± 7.5, while in SSFP in males it was 64.7 ± 9.3 and in females it was 52.0 ± 7.4. For TGE the RV EDV/BSA (mL/m 2) in males was 78.4 ± 14.0 and in females it was 67.5 ± 12.7, while in SSFP in males it was 86.2 ± 14.1 and in females it was 75.2 ± 13.8. Conclusion: We have provided normal ranges that are gender specific as well as data that can be used for age‐specific normal ranges for both SSFP and TGE pulse sequences. J. Magn. Reson. Imaging 2003;17:323–329. © 2003 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.10262

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 23

  1. 10.1016/S0735-1097(86)80100-0 · DOI
  2. 10.1016/S0735-1097(86)80099-7 · DOI
  3. 10.1016/0002-8703(89)90791-6 · DOI
  4. 10.1148/radiology.169.2.2971985 · DOI · Paper page
  5. 10.1093/oxfordjournals.eurheartj.a062539 · DOI
  6. 10.1016/0002-9149(90)90828-O · DOI
  7. 10.1148/radiology.188.2.8327681 · DOI · Paper page
  8. 10.1016/0730-725X(94)00076-F · DOI · Paper page
  9. Fieno DS, 2002, TrueFISP: assessment of accuracy for measurement of left ventricular mass in an animal model, J Cardiovasc Magn Reson, 15, 526
  10. 10.3109/10976649909080829 · DOI · Paper page
  11. 10.1023/A:1006268405585 · DOI
  12. 10.1002/jmri.1178 · DOI · Paper page
  13. 10.1002/jmri.1195 · DOI · Paper page
  14. 10.1007/s003300050072 · DOI · Paper page
  15. 10.1002/1522-2586(200011)12:5<678::AID-JMRI4>3.0.CO;2-5 · DOI
  16. 10.1136/hrt.40.11.1257 · doi:10.1136/hrt.40.11.1257
  17. 10.1002/jmri.1178 · DOI · Paper page
  18. 10.1161/01.CIR.55.4.613 · DOI · Paper page
  19. 10.1016/S0735-1097(84)80141-2 · DOI · Paper page
  20. 10.1097/00004872-199816060-00001 · DOI
  21. 10.1016/0002-9149(81)90214-9 · doi:10.1016/0002-9149(81)90214-9
  22. 10.1016/0735-1097(94)00375-Z · DOI · Paper page
  23. 10.1093/oxfordjournals.eurheartj.a060307 · DOI

Cited by

See all 732

Metadata

Authors
Alfakih, K., Plein, S., Thiele, H., Jones, T., Ridgway, J. P., & Sivananthan, M. U.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2003-02-19
Volume
17
Issue
3
Pages
323-329
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2066990527
Cited by
732
References
1
FWCI
23.54
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady‐state free precession imaging sequences. https://app.cochat.ai/papers/10.1002/jmri.10262
The paper
Alfakih, K., Plein, S., Thiele, H., Jones, T., Ridgway, J. P., & Sivananthan, M. U. (2003). Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady‐state free precession imaging sequences. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.10262

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.