The DOI matches its Crossref record.
The European ST-T database: standard for evaluating systems for the analysis of ST-T changes in ambulatory electrocardiography
Abstract
The project for the development of the European ST-T annotated Database originated from a 'Concerted Action' on Ambulatory Monitoring, set up by the European Community in 1985. The goal was to prototype an ECG database for assessing the quality of ambulatory ECG monitoring (AECG) systems. After the 'concerted action', the development of the full database was coordinated by the Institute of Clinical Physiology of the National Research Council (CNR) in Pisa and the Thoraxcenter of Erasmus University in Rotterdam. Thirteen research groups from eight countries provided AECG tapes and annotated beat by beat the selected 2-channel records, each 2 h in duration. ST segment (ST) and T-wave (T) changes were identified and their onset, offset and peak beats annotated in addition to QRSs, beat types, rhythm and signal quality changes. In 1989, the European Society of Cardiology sponsored the remainder of the project. Recently the 90 records were completed and stored on CD-ROM. The records include 372 ST and 423 T changes. In cooperation with the Biomedical Engineering Centre of MIT (developers of the MIT-BIH arrhythmia database), the annotation scheme was revised to be consistent with both MIT-BIH and American Heart Association formats.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Wavelet-Based ECG Delineator: Evaluation on Standard Databases
Martinez, J. P., Almeida, R., Olmos, S., Rocha, A. P., & Laguna, P. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821031 · Cited by 1,605
PTB-XL, a large publicly available electrocardiography dataset
Wagner, P., Strodthoff, N., Bousseljot, R.-D., Kreiseler, D., Lunze, F. I., Samek, W., & Schaeffter, T. (2020) · Scientific Data · doi:10.1038/s41597-020-0495-6 · Cited by 1,315
ECG-based heartbeat classification for arrhythmia detection: A survey
Luz, E. J. D. S., Schwartz, W. R., Cámara-Chávez, G., & Menotti, D. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.12.008 · Cited by 878
Liu, F., Liu, C., Zhao, L., Zhang, X., Wu, X., Xu, X., Liu, Y., Ma, C., Wei, S., He, Z., et al. (2018) · Journal of Medical Imaging and Health Informatics · doi:10.1166/jmihi.2018.2442 · Cited by 620
Clustering ECG complexes using Hermite functions and self-organizing maps
Lagerholm, M., Peterson, C., Braccini, G., Edenbrandt, L., & Sornmo, L. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.846677 · Cited by 547
Metadata
- Authors
- TADDEI, A., DISTANTE, G., EMDIN, M., PISANI, P., MOODY, G. B., ZEELENBERG, C., & MARCHESI, C.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-09
- Volume
- 13
- Issue
- 9
- Pages
- 1164-1172
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2146254945
- Cited by
- 436
- References
- 0
- FWCI
- 0.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The European ST-T database: standard for evaluating systems for the analysis of ST-T changes in ambulatory electrocardiography. https://app.cochat.ai/papers/10.1093/oxfordjournals.eurheartj.a060332
- The paper
- TADDEI, A., DISTANTE, G., EMDIN, M., PISANI, P., MOODY, G. B., ZEELENBERG, C., & MARCHESI, C. (1992). The European ST-T database: standard for evaluating systems for the analysis of ST-T changes in ambulatory electrocardiography. European Heart Journal. https://doi.org/10.1093/oxfordjournals.eurheartj.a060332
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.