The European ST-T database: standard for evaluating systems for the analysis of ST-T changes in ambulatory electrocardiography
The DOI matches its Crossref record.
Abstract
The project for the development of the European ST-T annotated Database originated from a 'Concerted Action' on Ambulatory Monitoring, set up by the European Community in 1985. The goal was to prototype an ECG database for assessing the quality of ambulatory ECG monitoring (AECG) systems. After the 'concerted action', the development of the full database was coordinated by the Institute of Clinical Physiology of the National Research Council (CNR) in Pisa and the Thoraxcenter of Erasmus University in Rotterdam. Thirteen research groups from eight countries provided AECG tapes and annotated beat by beat the selected 2-channel records, each 2 h in duration. ST segment (ST) and T-wave (T) changes were identified and their onset, offset and peak beats annotated in addition to QRSs, beat types, rhythm and signal quality changes. In 1989, the European Society of Cardiology sponsored the remainder of the project. Recently the 90 records were completed and stored on CD-ROM. The records include 372 ST and 423 T changes. In cooperation with the Biomedical Engineering Centre of MIT (developers of the MIT-BIH arrhythmia database), the annotation scheme was revised to be consistent with both MIT-BIH and American Heart Association formats.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Wavelet-Based ECG Delineator: Evaluation on Standard Databases
Martinez, J. P., Almeida, R., Olmos, S., Rocha, A. P., & Laguna, P. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821031 · Cited by 1,605
PTB-XL, a large publicly available electrocardiography dataset
Wagner, P., Strodthoff, N., Bousseljot, R.-D., Kreiseler, D., Lunze, F. I., Samek, W., & Schaeffter, T. (2020) · Scientific Data · doi:10.1038/s41597-020-0495-6 · Cited by 1,315
ECG-based heartbeat classification for arrhythmia detection: A survey
Luz, E. J. D. S., Schwartz, W. R., Cámara-Chávez, G., & Menotti, D. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.12.008 · Cited by 878
Liu, F., Liu, C., Zhao, L., Zhang, X., Wu, X., Xu, X., Liu, Y., Ma, C., Wei, S., He, Z., et al. (2018) · Journal of Medical Imaging and Health Informatics · doi:10.1166/jmihi.2018.2442 · Cited by 620
Clustering ECG complexes using Hermite functions and self-organizing maps
Lagerholm, M., Peterson, C., Braccini, G., Edenbrandt, L., & Sornmo, L. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.846677 · Cited by 547
Al’Aref, S. J., Anchouche, K., Singh, G., Slomka, P. J., Kolli, K. K., Kumar, A., Pandey, M., Maliakal, G., van Rosendael, A. R., Beecy, A. N., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy404 · Cited by 534
A 12-lead electrocardiogram database for arrhythmia research covering more than 10,000 patients
Zheng, J., Zhang, J., Danioko, S., Yao, H., Guo, H., & Rakovski, C. (2020) · Scientific Data · doi:10.1038/s41597-020-0386-x · Cited by 487
PhysioNet: a Web-based resource for the study of physiologic signals
Moody, G. B., Mark, R. G., & Goldberger, A. L. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932728 · Cited by 386
Self-citationAnsari, Y., Mourad, O., Qaraqe, K., & Serpedin, E. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1246746 · Cited by 291
Analysis of heart rate variability in the presence of ectopic beats using the heart timing signal
Mateo, J., & Laguna, P. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.808831 · Cited by 288
Artificial neural networks for automatic ECG analysis
Silipo, R., & Marchesi, C. (1998) · IEEE Transactions on Signal Processing · doi:10.1109/78.668803 · Cited by 282
Self-citationA database to support development and evaluation of intelligent intensive care monitoring
Moody, G. B., & Mark, R. G. (2002) · Computers in Cardiology 1996 · doi:10.1109/cic.1996.542622 · Cited by 244
Self-citationECG Authentication for Mobile Devices
Arteaga-Falconi, J. S., Al Osman, H., & El Saddik, A. (2016) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2015.2503863 · Cited by 200
Evolution, Current Challenges, and Future Possibilities in ECG Biometrics
Ribeiro Pinto, J., Cardoso, J. S., & Lourenco, A. (2018) · IEEE Access · doi:10.1109/access.2018.2849870 · Cited by 195
“5 A total of 203 healthy subjects were recorded using a Holter monitor during 24 hours, with four electrodes placed on the chest, from 3 leads following a pseudo-orthogonal configuration; • European ST-T: The European ST-T database [80] was originally intended for the analysis of ST and T-wave changes.”
MethodWasimuddin, M., Elleithy, K., Abuzneid, A.-S., Faezipour, M., & Abuzaghleh, O. (2020) · IEEE Access · doi:10.1109/access.2020.3026968 · Cited by 194
Jager, F., Taddei, A., Moody, G. B., Emdin, M., Antolič, G., Dorn, R., Smrdel, A., Marchesi, C., & Mark, R. G. (2003) · Medical and Biological Engineering and Computing · doi:10.1007/bf02344885 · Cited by 185
Self-citationECG analysis using nonlinear PCA neural networks for ischemia detection
Stamkopoulos, T., Diamantaras, K., Maglaveras, N., & Strintzis, M. (1998) · IEEE Transactions on Signal Processing · doi:10.1109/78.726818 · Cited by 160
“is satisfied, where is the sampling frequency, which in our case is 250 Hz [34].”
BackgroundMethodResultInfluentialA Rough-Set-Based Inference Engine for ECG Classification
Mitra, S., Mitra, M., & Chaudhuri, B. B. (2006) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2006.884279 · Cited by 159
“The simulation comparison of classification results between the proposed method and such other methods [15], [31], [32], [35], [36] is given in Table V.”
ResultLee, S., Chu, Y., Ryu, J., Park, Y. J., Yang, S., & Koh, S. B. (2022) · Yonsei Medical Journal · doi:10.3349/ymj.2022.63.s93 · Cited by 88
Pre-training in Medical Data: A Survey
Qiu, Y., Lin, F., Chen, W., & Xu, M. (2023) · Machine Intelligence Research · doi:10.1007/s11633-022-1382-8 · Cited by 30
“MIT-BIH noise stress test[64] ECG 15 1 Denoise 360 Hz CNN: Acc: 96.”
MethodA comprehensive review of AI-Based detection of Arrhythmia using Electrocardiogram (ECG)
Ayyub, A., Politis, C., & Usman, M. A. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110594 · Cited by 18
Metadata
- Authors
- TADDEI, A., DISTANTE, G., EMDIN, M., PISANI, P., MOODY, G. B., ZEELENBERG, C., & MARCHESI, C.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-09
- Volume
- 13
- Issue
- 9
- Pages
- 1164-1172
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2146254945
- Cited by
- 436
- References
- 0
- FWCI
- 0.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.