Heart rate variability and inappropriate sinus tachycardia after catheter ablation of supraventricular tachycardia
The DOI matches its Crossref record.
Abstract
Sinus tachycardia has been reported after radiofrequency catheter ablation of supraventricular tachycardia. Frequently, these patients require beta-blocking agents for symptomatic control. The purpose of this study was to evaluate prospectively the incidence of inappropriate sinus tachycardia and heart rate variability after ablation of atrioventricular nodal reentrant tachycardia and accessory pathways. Patients undergoing ablation had 24-h ambulatory monitoring ECG (Holter) performed before the procedure, on the day of the ablation, and 3 months afterwards. There were 170 patients, mean age 48 +/- 23 years; 93 were female. A complete study of the 24-h Holter with analysis of heart rate variability: SD, rMSSD, pNN50, high and low frequency was obtained. There was a low prevalence of inappropriate sinus tachycardia after the ablation procedure (10 of 170 patients: five with four atrioventricular nodal reentry, with posteroseptal accessory pathways and one of the latter following ablation of the left accessory pathway). There was no modification of time and frequency domain parameters of heart rate variability in the remaining patients who underwent radiofrequency ablation. Holter monitoring 3 months after ablation showed that parameters of heart rate and heart rate variability had normalized in patients who had developed inappropriate sinus tachycardia. Inappropriate sinus tachycardia may be initiated by both radiofrequency ablation of atrioventricular nodal reentrant tachycardia and radiofrequency ablation of posteroseptal accessory pathways. Specific damage to the posteroseptal region is responsible for these changes, which usually recover spontaneously after 3 months.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hsieh, M.-H., Chiou, C.-W., Wen, Z.-C., Wu, C.-H., Tai, C.-T., Tsai, C.-F., Ding, Y.-A., Chang, M.-S., & Chen, S.-A. (1999) · Circulation · doi:10.1161/01.cir.100.22.2237 · Cited by 191
Prevalence, characteristics and natural course of inappropriate sinus tachycardia
STILL, A., RAATIKAINEN, P., YLITALO, A., KAUMA, H., IKAHEIMO, M., ANTEROKESANIEMI, Y., & HUIKURI, H. (2005) · Europace · doi:10.1016/j.eupc.2004.12.007 · Cited by 134
Inappropriate sinus tachycardia
Olshansky, B., & Sullivan, R. M. (2019) · EP Europace · doi:10.1093/europace/euy128 · Cited by 80
Diurnal Heart Rate Patterns in Inappropriate Sinus Tachycardia
RUBENSTEIN, J. C., FREHER, M., KADISH, A., & GOLDBERGER, J. J. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02725.x · Cited by 23
What’s so inappropriate about sinus tachycardia?
OLSHANSKY, B. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01179.x · Cited by 12
Metadata
- Authors
- MADRID, A. H., MESTRE, J. L., MORO, C., VIVAS, E., TEJERO, I., NOVO, L., MARIN, E., & ORELLANA, L.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 1995-11
- Volume
- 16
- Issue
- 11
- Pages
- 1637-1640
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W12473195
- Cited by
- 30
- References
- 0
- FWCI
- 1.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heart rate variability and inappropriate sinus tachycardia after catheter ablation of supraventricular tachycardia. https://app.cochat.ai/papers/10.1093/oxfordjournals.eurheartj.a060789
- The paper
- MADRID, A. H., MESTRE, J. L., MORO, C., VIVAS, E., TEJERO, I., NOVO, L., MARIN, E., & ORELLANA, L. (1995). Heart rate variability and inappropriate sinus tachycardia after catheter ablation of supraventricular tachycardia. European Heart Journal. https://doi.org/10.1093/oxfordjournals.eurheartj.a060789
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.