Active Dosimetry on Recent Space Flights
The DOI matches its Crossref record.
Abstract
The radiation exposure inside the spacecraft in low earth orbit was investigated with a telescope based on two silicon planar detectors during three NASA shuttle-to-MIR missions (inclination 51.6 deg, altitude about 380 km). Count and dose rate profiles were measured, as well as separate linear energy transfer (LET) spectra, for the galactic cosmic rays (GCR) and the trapped radiation encountered in the South Atlantic Anomaly (SAA). Effective quality factors are deduced from the converted LET spectra (in water) in the range 0.1-120 keV micrometer-1 according to ICRP 60. Measured mission averaged dose rates in silicon are in the range 98-108 microGy d-1 and 137-178 microGy d-1 for the GCR and SAA contributions, respectively. The deduced effective quality factors are 2.95-3.29 (GCR) and 1.18-1.25 (SAA), resulting in mission averaged dose equivalent rates of 631-716 microSv d-1 for the comparable three missions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Space radiation dosimetry in low-Earth orbit and beyond
Benton, E. R., & Benton, E. V. (2001) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/s0168-583x(01)00748-0 · Cited by 538
ICRP Publication 123: Assessment of Radiation Exposure of Astronauts in Space
Dietze, G., Bartlett, D. T., Cool, D. A., Cucinotta, F. A., Jia, X., McAulay, I. R., Pelliccioni, M., Petrov, V., Reitz, G., & Sato, T. (2013) · Annals of the ICRP · doi:10.1016/j.icrp.2013.05.004 · Cited by 239
Self-citationSpace radiation measurements on-board ISS—the DOSMAP experiment
Reitz, G., Beaujean, R., Benton, E., Burmeister, S., Dachev, T., Deme, S., Luszik-Bhadra, M., & Olko, P. (2005) · Radiation Protection Dosimetry · doi:10.1093/rpd/nci262 · Cited by 109
Self-citationSpace Radiation Absorbed Dose Distribution in a Human Phantom
Badhwar, G. D., Atwell, W., Badavi, F. F., Yang, T. C., & Cleghorn, T. F. (2002) · Radiation Research · doi:10.1667/0033-7587(2002)157[0076:sraddi]2.0.co;2 · Cited by 86
Berger, T., Burmeister, S., Matthiä, D., Przybyla, B., Reitz, G., Bilski, P., Hajek, M., Sihver, L., Szabo, J., Ambrozova, I., et al. (2017) · Journal of Space Weather and Space Climate · doi:10.1051/swsc/2017005 · Cited by 72
Self-citation
Metadata
- Authors
- Beaujean, R., Kopp, J., & Reitz, G.
- Venue
- Radiation Protection Dosimetry
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-09-01
- Volume
- 85
- Issue
- 1
- Pages
- 223-226
- ISSN
- 0144-8420 (ISSN-L)
- 1742-3406
- OpenAlex
- W2322458794
- Cited by
- 36
- References
- 0
- FWCI
- 3.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Active Dosimetry on Recent Space Flights. https://app.cochat.ai/papers/10.1093/oxfordjournals.rpd.a032839
- The paper
- Beaujean, R., Kopp, J., & Reitz, G. (1999). Active Dosimetry on Recent Space Flights. Radiation Protection Dosimetry. https://doi.org/10.1093/oxfordjournals.rpd.a032839
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.