The DOI matches its Crossref record.
Calculation of Heavy Ion Inactivation Probabilities Based on Track Structure, X Ray Sensitivity and Target Size
Abstract
A track structure model for the calculation of inactivation probabilities of heavy ions has been developed, which is based on measurable quantities only. The model describes the following inactivation properties of heavy ion radiation: (1) the transition from shouldered to exponential survival curves, depending on the atomic number, energy and LET of the particle; (2) the LET dependence of inactivation cross sections s, including the supralinear increase for low LET particles, the plateau region between 200 and 1000 keV.µm-1 and the s LET hooks for higher LET values; (3) differences in the shape of the s LET hooks for different biological objects; (4) the shift of RBE maxima from 30 to 300 keV.µm-1 with increasing atomic number; (5) the exchanged efficiency of heavy ions in the case of mixed radiation fields (X rays combined with heavy ion irradiation).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Computation of cell survival in heavy ion beams for therapy
Scholz, M., Kellerer, A. M., Kraft-Weyrather, W., & Kraft, G. (1997) · Radiation and Environmental Biophysics · doi:10.1007/s004110050055 · Cited by 464
Self-citationBiological consequences of nanoscale energy deposition near irradiated heavy atom nanoparticles
McMahon, S. J., Hyland, W. B., Muir, M. F., Coulter, J. A., Jain, S., Butterworth, K. T., Schettino, G., Dickson, G. R., Hounsell, A. R., O'Sullivan, J. M., et al. (2011) · Scientific Reports · doi:10.1038/srep00018 · Cited by 429
Track structure and the calculation of biological effects of heavy charged particles
Scholz, M., & Kraft, G. (1996) · Advances in Space Research · doi:10.1016/0273-1177(95)00784-c · Cited by 265
Self-citationCarante, M. P., Aimè, C., Cajiao, J. J. T., & Ballarini, F. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aab45f · Cited by 52
Hullo, M., Grall, R., Perrot, Y., Mathé, C., Ménard, V., Yang, X., Lacombe, S., Porcel, E., Villagrasa, C., Chevillard, S., et al. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22094436 · Cited by 48
Metadata
- Authors
- Scholz, M., & Kraft, G.
- Venue
- Radiation Protection Dosimetry
- Publisher
- Oxford University Press (OUP)
- Published
- 1994-04-01
- Volume
- 52
- Issue
- 1-4
- Pages
- 29-33
- ISSN
- 0144-8420 (ISSN-L)
- 1742-3406
- OpenAlex
- W2524816764
- Cited by
- 170
- References
- 0
- FWCI
- 4.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calculation of Heavy Ion Inactivation Probabilities Based on Track Structure, X Ray Sensitivity and Target Size. https://app.cochat.ai/papers/10.1093/oxfordjournals.rpd.a082156
- The paper
- Scholz, M., & Kraft, G. (1994). Calculation of Heavy Ion Inactivation Probabilities Based on Track Structure, X Ray Sensitivity and Target Size. Radiation Protection Dosimetry. https://doi.org/10.1093/oxfordjournals.rpd.a082156
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.