The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Iron and Nickel Line Diagnostics for the Galactic Center Diffuse Emission
Open accessAbstract
We have observed the diffuse X-ray emission from the Galactic Center (GC) using the X-ray Imaging Spectrometer (XIS) on Suzaku. The high-energy resolution and the low-background orbit provided excellent spectra of the GC diffuse X-rays (GCDX). The XIS found many emission lines in the GCDX near the energy of K-shell transitions of iron and nickel. The most pronounced features are Fe I $\mathrm{K}\alpha$ at 6.4 keV and K-shell absorption edge at 7.1 keV, which are from neutral and/or low ionization states of iron, and the K-shell lines at 6.7 keV and 6.9 keV from He-like (Fe XXV $\mathrm{K}\alpha$) and hydrogenic (Fe XXVI Ly$\alpha$) ions of iron. In addition, $\mathrm{K}\alpha$ lines from neutral or low ionization nickel (Ni I $\mathrm{K}\alpha$) and He-like nickel (Ni XXVII $\mathrm{K}\alpha$), Fe I $\mathrm{K}\beta$, Fe XXV $\mathrm{K}\beta$, Fe XXVI $\mathrm{Ly}\beta$, Fe XXV $\mathrm{K}\gamma$, and Fe XXVI $\mathrm{Ly}\gamma$ were detected for the first time. The line center energies and widths of Fe XXV $\mathrm{K}\alpha$ and Fe XXVI $\mathrm{Ly}\alpha$ favor a collisional excitation plasma for the origin of the GCDX. The electron temperature determined from the line flux ratio of Fe XXV $\mathrm{K}\alpha$$/$ Fe XXV $\mathrm{K}\beta$ is similar to the ionization temperature determined from that of Fe XXV $\mathrm{K}\alpha$$/$ Fe XXVI $\mathrm{Ly}\alpha$. Thus it would appear that the GCDX plasma is close to ionization equilibrium. The 6.7 keV flux and temperature distribution to the galactic longitude is smooth and monotonic, in contrast to the integrated point source flux distribution. These facts support the hypothesis that the GCDX is truly diffuse emission rather than the integration of the outputs of a large number of unresolved point sources. In addition, our results demonstrate that the chemical composition of Fe in the interstellar gas near the GC is constrained to be about 3.5 times solar abundance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diffuse X‐Ray Emission in a Deep Chandra Image of the Galactic Center
Muno, M. P., Baganoff, F. K., Bautz, M. W., Feigelson, E. D., Garmire, G. P., Morris, M. R., Park, S., Ricker, G. R., & Townsley, L. K. (2004) · The Astrophysical Journal · doi:10.1086/422865 · Cited by 221 · cited 4×
“We simulated the point-source flux in the 4.7–8.0 keV band observed with XIS, putting the positions and fluxes (2.0–8.0 keV band) of the Chandra cataloged sources (Muno et al. 2003) in the same rectangles of figure 4.”
MethodInfluential
Cited by
X-Ray Imaging Spectrometer (XIS) on Board Suzaku
Koyama, K., Tsunemi, H., Dotani, T., Bautz, M. W., Hayashida, K., Tsuru, T. G., Matsumoto, H., Ogawara, Y., Ricker, G. R., Doty, J., et al. (2007) · Publications of the Astronomical Society of Japan · doi:10.1093/pasj/59.sp1.s23 · Cited by 1,044
Self-citationFermi Bubbles: Giant, Multibillion-Year-Old Reservoirs of Galactic Center Cosmic Rays
Crocker, R. M., & Aharonian, F. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.101102 · Cited by 242
Cheng, K.-S., Chernyshov, D. O., Dogiel, V. A., Ko, C.-M., & Ip, W.-H. (2011) · The Astrophysical Journal · doi:10.1088/2041-8205/731/1/l17 · Cited by 120
Echoes of multiple outbursts of Sagittarius A⋆revealed by Chandra
Clavel, M., Terrier, R., Goldwurm, A., Morris, M. R., Ponti, G., Soldi, S., & Trap, G. (2013) · Astronomy & Astrophysics · doi:10.1051/0004-6361/201321667 · Cited by 114
“In order to reduce the number of free parameters, the hot-plasma temperature is fixed to 6.5 keV (Koyama et al. 2007) and the same normalization is used across the years for a given region.”
BackgroundMethodInfluentialInui, T., Koyama, K., Matsumoto, H., & Tsuru, T. G. (2009) · Publications of the Astronomical Society of Japan · doi:10.1093/pasj/61.sp1.s241 · Cited by 95
Self-citation
Metadata
- Authors
- Koyama, K., Hyodo, Y., Inui, T., Nakajima, H., Matsumoto, H., Tsuru, T. G., Takahashi, T., Maeda, Y., Yamazaki, N. Y., Murakami, H., Yamauchi, S., Tsuboi, Y., Senda, A., Kataoka, J., Takahashi, H., Holt, S. S., & Brown, G. V.
- Venue
- Publications of the Astronomical Society of Japan
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-01-30
- Volume
- 59
- Issue
- sp1
- Pages
- S245-S255
- ISSN
- 0004-6264 (ISSN-L)
- 2053-051X
- OpenAlex
- W2162900328
- Cited by
- 159
- References
- 1
- FWCI
- 12.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Iron and Nickel Line Diagnostics for the Galactic Center Diffuse Emission. https://app.cochat.ai/papers/10.1093/pasj/59.sp1.s245
- The paper
- Koyama, K., Hyodo, Y., Inui, T., Nakajima, H., Matsumoto, H., Tsuru, T. G., Takahashi, T., Maeda, Y., Yamazaki, N. Y., Murakami, H., Yamauchi, S., Tsuboi, Y., Senda, A., Kataoka, J., Takahashi, H., Holt, S. S., & Brown, G. V. (2007). Iron and Nickel Line Diagnostics for the Galactic Center Diffuse Emission. Publications of the Astronomical Society of Japan. https://doi.org/10.1093/pasj/59.sp1.s245
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.