Reliability of Goniometric Measurements in Patients with Duchenne Muscular Dystrophy
The DOI matches its Crossref record.
Abstract
Previous studies of reliability of goniometric measurements have produced varied findings suggesting the need to document further the reliability of measuring range of motion in different patient groups. The purpose of this study was to determine the intratester and intertester reliability of goniometric measurements of seven common upper and lower extremity joint limitations in children with Duchenne muscular dystrophy. Five physical therapists participated in the study. The procedure and order of measurements were standardized. Results showed that intratester reliability for all measurements was high (ICC = .81 to .94), but intertester reliability showed a wide variation (ICC = .25 to .91). The results of this study indicate the need to use the same examiner for long-term follow-up and for assessing results of specific treatment interventions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bushby, K., Finkel, R., Birnkrant, D. J., Case, L. E., Clemens, P. R., Cripe, L., Kaul, A., Kinnett, K., McDonald, C., Pandya, S., et al. (2010) · The Lancet Neurology · doi:10.1016/s1474-4422(09)70271-6 · Cited by 2,053
Self-citationClinical Measurement of Range of Motion
Gajdosik, R. L., & Bohannon, R. W. (1987) · Physical Therapy · doi:10.1093/ptj/67.12.1867 · Cited by 898
Pope, R., Herbert, R., & Kirwan, J. (1998) · Australian Journal of Physiotherapy · doi:10.1016/s0004-9514(14)60376-7 · Cited by 297
Randomized phase 2 trial and open-label extension of domagrozumab in Duchenne muscular dystrophy
Wagner, K. R., Abdel-Hamid, H. Z., Mah, J. K., Campbell, C., Guglieri, M., Muntoni, F., Takeshima, Y., McDonald, C. M., Kostera-Pruszczyk, A., Karachunski, P., et al. (2020) · Neuromuscular Disorders · doi:10.1016/j.nmd.2020.05.002 · Cited by 67
“The North Star Ambulatory Assessment (NSAA) [15-17] , range of motion using goniometry [18] , Performance of Upper Limb (PUL) [ 19 , 20 ], 6-minute-walk distance (6MWD) [21] , pulmonary function based on forced vital capacity (FVC) using spirometry [ 17 , 22 ], and strength assessed by hand-held myometry were conducte…”
Valagussa, G., Balatti, V., Trentin, L., Piscitelli, D., Yamagata, M., & Grossi, E. (2020) · Journal of Orthopaedics · doi:10.1016/j.jor.2020.08.013 · Cited by 10
Metadata
- Authors
- Pandya, S., Florence, J. M., King, W. M., Robison, J. D., Oxman, M., & Province, M. A.
- Venue
- Physical Therapy
- Publisher
- Oxford University Press (OUP)
- Published
- 1985-09-01
- Volume
- 65
- Issue
- 9
- Pages
- 1339-1342
- ISSN
- 0031-9023 (ISSN-L)
- 1538-6724
- OpenAlex
- W2128768501
- Cited by
- 127
- References
- 0
- FWCI
- 2.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability of Goniometric Measurements in Patients with Duchenne Muscular Dystrophy. https://app.cochat.ai/papers/10.1093/ptj/65.9.1339
- The paper
- Pandya, S., Florence, J. M., King, W. M., Robison, J. D., Oxman, M., & Province, M. A. (1985). Reliability of Goniometric Measurements in Patients with Duchenne Muscular Dystrophy. Physical Therapy. https://doi.org/10.1093/ptj/65.9.1339
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.