Reliability of Measurements of Concentric and Eccentric Isokinetic Loading
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The purpose of this study was to assess the reliability of a method for testing peak torque and work output of the knee extensor muscle during concentric and eccentric loading at three velocities of exercise (60 degrees, 120 degrees, and 180 degrees/sec). Fourteen healthy men (23-32 years of age) performed exercises of the quadriceps femoris muscles during concentric and eccentric loading, with a five-second pause between each contraction. Three different tests were performed on different occasions. The first exercise session was a practice session, and the next two sessions were established to collect data in a test-retest format. Peak torque and work were measured for the two testing sessions. The results of this study demonstrated that with a very specific protocol, the reliability of concentric peak torque and work measurements was excellent at 60 degrees and 120 degrees/sec and good at 180 degrees/sec. In contrast, reliability of eccentric peak torque and work measurements was good at 120 degrees and 180 degrees/sec but low at 60 degrees/sec.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Cited by
Reliability of Power in Physical Performance Tests
Hopkins, W. G., Schabort, E. J., & Hawley, J. A. (2001) · Sports Medicine · doi:10.2165/00007256-200131030-00005 · Cited by 825
Muscle activation during maximal voluntary eccentric and concentric knee extension
Westing, S. H., Cresswell, A. G., & Thorstensson, A. (1991) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00626764 · Cited by 362
Test-Retest Reliability of the Biodex Isokinetic Dynamometer
Feiring, D. C., Ellenbecker, T. S., & Derscheid, G. L. (1990) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.1990.11.7.298 · Cited by 359
Test-Retest Reliability of Isokinetic Knee Extension and Flexion
Sole, G., Hamrén, J., Milosavljevic, S., Nicholson, H., & Sullivan, S. J. (2007) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.02.006 · Cited by 284
WESTING, S. H., SEGER, J. Y., & THORSTENSSON, A. (1990) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1990.tb08971.x · Cited by 258
Age, Gender, and Muscular Strength
Evans, W. J., & Hurley, B. F. (1995) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/50a.special_issue.41 · Cited by 198
Sleivert, G. G., & Wenger, H. A. (1994) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/0003-9993(94)90279-8 · Cited by 155
Heywood, S., McClelland, J., Mentiplay, B., Geigle, P., Rahmann, A., & Clark, R. (2017) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2016.08.472 · Cited by 87
Early Phase Differential Effects of Slow and Fast Barbell Squat Training
Morrissey, M. C., Harman, E. A., Frykman, P. N., & Han, K. H. (1998) · The American Journal of Sports Medicine · doi:10.1177/03635465980260021101 · Cited by 75
Metadata
- Authors
- Tredinnick, T. J., & Duncan, P. W.
- Venue
- Physical Therapy
- Publisher
- Oxford University Press (OUP)
- Published
- 1988-05-01
- Volume
- 68
- Issue
- 5
- Pages
- 656-659
- ISSN
- 0031-9023 (ISSN-L)
- 1538-6724
- OpenAlex
- W2259904860
- Cited by
- 136
- References
- 1
- FWCI
- 6.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.