The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Reliability of Measurements of Cervical Spine Range of Motion—Comparison of Three Methods
Abstract
To determine reliabilities within and between persons measuring cervical active range of motion (AROM) three methods were examined: use of a cervical-range-of-motion (CROM) instrument, use of a universal goniometer (UG), and visual estimation (VE). Measurements were made on 60 patients with orthopedic disorders of the cervical spine who were divided into three groups of 20 subjects each. All subjects were tested in a standardized seated position using operationally defined goniometric placements and nongoniometric estimation techniques. Cervical flexion and extension, lateral flexion, and rotation were measured. Intraclass correlation coefficients (ICCs) were used to quantify within-tester and between-tester reliability. We found that goniometric measurements of AROM of the cervical spine made by the same physical therapist had ICCs greater than .80 when made with the CROM device or the UG. When different physical therapist measured the same patient's cervical AROM, the CROM device had ICCs greater than .80, whereas the UG and VE generally had ICCs less than .80.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Measurement of Joint Motion: A guide to goniometry
Norkin, C. C., & White, D. (1985) · Medical Entomology and Zoology · Cited by 1,118
Clinical Measurement of Range of Motion
Gajdosik, R. L., & Bohannon, R. W. (1987) · Physical Therapy · doi:10.1093/ptj/67.12.1867 · Cited by 898
Goniometric Reliability in a Clinical Setting
Rothstein, J. M., Miller, P. J., & Roettger, R. F. (1983) · Physical Therapy · doi:10.1093/ptj/63.10.1611 · Cited by 546
Goniometric Reliability in a Clinical Setting
Riddle, D. L., Rothstein, J. M., & Lamb, R. L. (1987) · Physical Therapy · doi:10.1093/ptj/67.5.668 · Cited by 398
Goniometric Reliability in a Clinical Setting
Elveru, R. A., Rothstein, J. M., & Lamb, R. L. (1988) · Physical Therapy · doi:10.1093/ptj/68.5.672 · Cited by 379
Krusen's Handbook of Physical Medicine and Rehabilitation.
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-9-823_5 · Cited by 321
Measurement in physical therapy
Rothstein, J. M. (1985) · Churchill Livingstone eBooks · Cited by 228
Cited by
Eliasziw, M., Young, S. L., Woodbury, M. G., & Fryday-Field, K. (1994) · Physical Therapy · doi:10.1093/ptj/74.8.777 · Cited by 635
Wainner, R. S., Fritz, J. M., Irrgang, J. J., Boninger, M. L., Delitto, A., & Allison, S. (2003) · Spine · doi:10.1097/00007632-200301010-00014 · Cited by 598
Normal Range of Motion of the Cervical Spine: An Initial Goniometric Study
Youdas, J. W., Garrett, T. R., Suman, V. J., Bogard, C. L., Hallman, H. O., & Carey, J. R. (1992) · Physical Therapy · doi:10.1093/ptj/72.11.770 · Cited by 404
Self-citationValidity and Between-Day Reliability of the Cervical Range of Motion (CROM) Device
Audette, I., Dumas, J.-P., Côté, J. N., & De Serres, S. J. (2010) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2010.3180 · Cited by 396
Fletcher, J. P., & Bandy, W. D. (2008) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2008.2680 · Cited by 304
Metadata
- Authors
- Youdas, J. W., Carey, J. R., & Garrett, T. R.
- Venue
- Physical Therapy
- Publisher
- Oxford University Press (OUP)
- Published
- 1991-02-01
- Volume
- 71
- Issue
- 2
- Pages
- 98-104
- ISSN
- 0031-9023 (ISSN-L)
- 1538-6724
- OpenAlex
- W2126545268
- Cited by
- 514
- References
- 8
- FWCI
- 4.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability of Measurements of Cervical Spine Range of Motion—Comparison of Three Methods. https://app.cochat.ai/papers/10.1093/ptj/71.2.98
- The paper
- Youdas, J. W., Carey, J. R., & Garrett, T. R. (1991). Reliability of Measurements of Cervical Spine Range of Motion—Comparison of Three Methods. Physical Therapy. https://doi.org/10.1093/ptj/71.2.98
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.