The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Intrarater Reliability of CROM Measurement of Cervical Spine Active Range of Motion in Persons With and Without Neck Pain
Abstract
STUDY DESIGN: Clinical measurement, intrarater reliability study. OBJECTIVES: To determine the intrarater reliability of cervical active range of motion (AROM) measurement of subjects with and without neck pain using the cervical range-of-motion device (CROM). BACKGROUND: Cervical spine AROM data are used by physical therapists to assist in identifying movement impairment, monitor patient progress, and evaluate the effectiveness of intervention. Presently, insufficient literature exists regarding the intrarater reliability of cervical AROM measurements using the CROM. METHODS AND MEASURES: Twenty-five adult subjects without neck pain and 22 adult subjects with neck pain volunteered for the study. Two trials of cervical AROM measurement (6 movements) were performed for each subject. Practice sessions, methods of measurement, and rest time between trials were standardized; order of measurement was randomized. RESULTS: The intraclass correlation coefficients (ICC3,1) for the subjects without neck pain ranged from 0.87 for flexion (95% confidence interval [CI]: 0.76-0.95) to 0.94 for left rotation (95% CI: 0.87-0.97). The standard error of the measurement ranged from 2.3 degrees to 4.0 degrees . The ICCs for the subjects with neck pain ranged from 0.88 for flexion (95% CI: 0.73-0.95) to 0.96 for left rotation (95% CI: 0.91-0.98). The standard error of the measurement ranged from 2.5 degrees to 4.1 degrees . Minimal detectable change ranged from 5.4 degrees for left rotation in the subjects without neck pain to 9.6 degrees for flexion in the subjects with neck pain. CONCLUSION: Intrarater reliability for cervical AROM measurement of persons with and without neck pain is sufficient to consider use of the CROM in clinical practice, although changes between 5 degrees to 10 degrees are needed to feel confident that a real change in spine mobility has occurred.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Forming inferences about some intraclass correlation coefficients.
McGraw, K. O., & Wong, S. P. (1996) · Psychological Methods · doi:10.1037/1082-989x.1.1.30 · Cited by 6,903
Fritz, J. M., & Irrgang, J. J. (2001) · Physical Therapy · doi:10.1093/ptj/81.2.776 · Cited by 1,045
Eliasziw, M., Young, S. L., Woodbury, M. G., & Fryday-Field, K. (1994) · Physical Therapy · doi:10.1093/ptj/74.8.777 · Cited by 635
Reliability of Measurements of Cervical Spine Range of Motion—Comparison of Three Methods
Youdas, J. W., Carey, J. R., & Garrett, T. R. (1991) · Physical Therapy · doi:10.1093/ptj/71.2.98 · Cited by 514
Stratford, P. W., & Goldsmith, C. H. (1997) · Physical Therapy · doi:10.1093/ptj/77.7.745 · Cited by 455
Normal Range of Motion of the Cervical Spine: An Initial Goniometric Study
Youdas, J. W., Garrett, T. R., Suman, V. J., Bogard, C. L., Hallman, H. O., & Carey, J. R. (1992) · Physical Therapy · doi:10.1093/ptj/72.11.770 · Cited by 404
Understanding the Relevance of Measured Change Through Studies of Responsiveness
Beaton, D. E. (2000) · Spine · doi:10.1097/00007632-200012150-00015 · Cited by 344
Lea, R. D., & Gerhardt, J. J. (1995) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199505000-00017 · Cited by 181
Intratester and intertester reliability of the cervical range of motion device.
CAPUANO-PUCCI, D. L., Rheault, W., Aukai, J., Bracke, M., Day, R. G., & Pastrick, M. (1991) · PubMed · Cited by 171
Cited by
Williams, S., Whatman, C., Hume, P. A., & Sheerin, K. (2012) · Sports Medicine · doi:10.2165/11594960-000000000-00000 · Cited by 563
Validity and Between-Day Reliability of the Cervical Range of Motion (CROM) Device
Audette, I., Dumas, J.-P., Côté, J. N., & De Serres, S. J. (2010) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2010.3180 · Cited by 396
GonzáLez-Iglesias, J., Fernández-de-las-Peñas, C., Cleland, J., Huijbregts, P., & Gutiérrez-Vega, M. D. R. (2009) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2009.3072 · Cited by 373
Munro, A., Herrington, L., & Carolan, M. (2012) · Journal of Sport Rehabilitation · doi:10.1123/jsr.21.1.7 · Cited by 265
Llamas-Ramos, R., Pecos-Martín, D., Gallego-Izquierdo, T., Llamas-Ramos, I., Plaza-Manzano, G., Ortega-Santiago, R., Cleland, J., & Fernández-de-las-Peñas, C. (2014) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2014.5229 · Cited by 185
Metadata
- Authors
- Fletcher, J. P., & Bandy, W. D.
- Venue
- Journal of Orthopaedic & Sports Physical Therapy
- Published
- 2008-10
- Volume
- 38
- Issue
- 10
- Pages
- 640-645
- ISSN
- 0190-6011 (ISSN-L)
- 1938-1344
- OpenAlex
- W2037528869
- Cited by
- 304
- References
- 19
- FWCI
- 4.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intrarater Reliability of CROM Measurement of Cervical Spine Active Range of Motion in Persons With and Without Neck Pain. https://app.cochat.ai/papers/10.2519/jospt.2008.2680
- The paper
- Fletcher, J. P., & Bandy, W. D. (2008). Intrarater Reliability of CROM Measurement of Cervical Spine Active Range of Motion in Persons With and Without Neck Pain. Journal of Orthopaedic & Sports Physical Therapy. https://doi.org/10.2519/jospt.2008.2680
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.