Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 304

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Intrarater Reliability of CROM Measurement of Cervical Spine Active Range of Motion in Persons With and Without Neck Pain

Fletcher, James P., Bandy, William D.·2008·Journal of Orthopaedic & Sports Physical Therapy

Abstract

STUDY DESIGN: Clinical measurement, intrarater reliability study. OBJECTIVES: To determine the intrarater reliability of cervical active range of motion (AROM) measurement of subjects with and without neck pain using the cervical range-of-motion device (CROM). BACKGROUND: Cervical spine AROM data are used by physical therapists to assist in identifying movement impairment, monitor patient progress, and evaluate the effectiveness of intervention. Presently, insufficient literature exists regarding the intrarater reliability of cervical AROM measurements using the CROM. METHODS AND MEASURES: Twenty-five adult subjects without neck pain and 22 adult subjects with neck pain volunteered for the study. Two trials of cervical AROM measurement (6 movements) were performed for each subject. Practice sessions, methods of measurement, and rest time between trials were standardized; order of measurement was randomized. RESULTS: The intraclass correlation coefficients (ICC3,1) for the subjects without neck pain ranged from 0.87 for flexion (95% confidence interval [CI]: 0.76-0.95) to 0.94 for left rotation (95% CI: 0.87-0.97). The standard error of the measurement ranged from 2.3 degrees to 4.0 degrees . The ICCs for the subjects with neck pain ranged from 0.88 for flexion (95% CI: 0.73-0.95) to 0.96 for left rotation (95% CI: 0.91-0.98). The standard error of the measurement ranged from 2.5 degrees to 4.1 degrees . Minimal detectable change ranged from 5.4 degrees for left rotation in the subjects without neck pain to 9.6 degrees for flexion in the subjects with neck pain. CONCLUSION: Intrarater reliability for cervical AROM measurement of persons with and without neck pain is sufficient to consider use of the CROM in clinical practice, although changes between 5 degrees to 10 degrees are needed to feel confident that a real change in spine mobility has occurred.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2519/jospt.2008.2680

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 304

Metadata

Authors
Fletcher, J. P., & Bandy, W. D.
Venue
Journal of Orthopaedic & Sports Physical Therapy
Published
2008-10
Volume
38
Issue
10
Pages
640-645
ISSN
  • 0190-6011 (ISSN-L)
  • 1938-1344
OpenAlex
W2037528869
Cited by
304
References
19
FWCI
4.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intrarater Reliability of CROM Measurement of Cervical Spine Active Range of Motion in Persons With and Without Neck Pain. https://app.cochat.ai/papers/10.2519/jospt.2008.2680
The paper
Fletcher, J. P., & Bandy, W. D. (2008). Intrarater Reliability of CROM Measurement of Cervical Spine Active Range of Motion in Persons With and Without Neck Pain. Journal of Orthopaedic & Sports Physical Therapy. https://doi.org/10.2519/jospt.2008.2680

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.