The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Chronic Dermal Ulcer Healing Enhanced with Monophasic Pulsed Electrical Stimulation
Open accessAbstract
The purposes of this randomized, double-blind, multicenter study were to compare healing of chronic dermal ulcers treated with pulsed electrical stimulation with healing of similar wounds treated with sham electrical stimulation and to evaluate patient tolerance to the therapeutic protocol. Forty-seven patients, aged 29 to 91 years, with 50 stage II, III, and IV ulcers were randomly assigned to either a treatment group (n = 26) or a control (sham treatment) group (n = 24). Treated wounds received 30 minutes of pulsed cathodal electrical stimulation twice daily at a pulse frequency of 128 pulses per second (pps) and a peak amplitude of 29.2 mA if the wound contained necrotic tissue or any drainage that was not serosanguinous. A saline-moistened nontreatment electrode was applied 30.5 cm (12 in) cephalad from the wound. This protocol was continued for 3 days after the wound was debrided or exhibited serosanguinous drainage. Thereafter, the polarity of the treatment electrode on the wound was changed every 3 days until the wound progressed to a stage II classification. The pulse frequency was then reduced to 64 pps, and the treatment electrode polarity was changed daily until the wound was healed. Patients in the control group were treated with the same protocol, except they received sham electrical stimulation. After 4 weeks, wounds in the treatment and control groups were 44% and 67% of their initial size, respectively. The healing rates per week for the treatment and control groups were 14% and 8.25%, respectively. The results of this study indicate that pulsed electrical stimulation has a beneficial effect on healing stage II, III, and IV chronic dermal ulcers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Treatment of delayed union and nonunion with an implanted direct current stimulator
PATERSON, D. C., LEWIS, G. N., & CASS, C. A. (1980) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198005000-00017 · Cited by 72
Cited by
Broughton, G., Janis, J. E., & Attinger, C. E. (2006) · Plastic and Reconstructive Surgery · doi:10.1097/01.prs.0000222562.60260.f9 · Cited by 917
Electrical Stimulation: A Novel Tool for Tissue Engineering
Balint, R., Cassidy, N. J., & Cartmell, S. H. (2013) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2012.0183 · Cited by 405
Ragnarsson, K. T. (2008) · Spinal Cord · doi:10.1038/sj.sc.3102091 · Cited by 301
Electrical Stimulation of Schwann Cells Promotes Sustained Increases in Neurite Outgrowth
Koppes, A. N., Nordberg, A. L., Paolillo, G. M., Goodsell, N. M., Darwish, H. A., Zhang, L., & Thompson, D. M. (2014) · Tissue Engineering Part A · doi:10.1089/ten.tea.2013.0012 · Cited by 108
Current concepts regarding the effect of wound microbial ecology and biofilms on wound healing
Black, C. E., & Costerton, J. W. (2010) · Surgical Clinics of North America · doi:10.1016/j.suc.2010.08.009 · Cited by 99
Metadata
- Authors
- Feedar, J. A., Kloth, L. C., & Gentzkow, G. D.
- Venue
- Physical Therapy
- Publisher
- Oxford University Press (OUP)
- Published
- 1991-09-01
- Volume
- 71
- Issue
- 9
- Pages
- 639-649
- ISSN
- 0031-9023 (ISSN-L)
- 1538-6724
- OpenAlex
- W2124471328
- Cited by
- 188
- References
- 1
- FWCI
- 2.80
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chronic Dermal Ulcer Healing Enhanced with Monophasic Pulsed Electrical Stimulation. https://app.cochat.ai/papers/10.1093/ptj/71.9.639
- The paper
- Feedar, J. A., Kloth, L. C., & Gentzkow, G. D. (1991). Chronic Dermal Ulcer Healing Enhanced with Monophasic Pulsed Electrical Stimulation. Physical Therapy. https://doi.org/10.1093/ptj/71.9.639
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.