The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
An Electromyographic Analysis of the Deep Cervical Flexor Muscles in Performance of Craniocervical Flexion
Abstract
Background and Purpose. This study evaluated an electromyographic technique for the measurement of muscle activity of the deep cervical flexor (DCF) muscles. Electromyographic signals were detected from the DCF, sternocleidomastoid (SCM), and anterior scalene (AS) muscles during performance of the craniocervical flexion (CCF) test, which involves performing 5 stages of increasing craniocervical flexion range of motion—the anatomical action of the DCF muscles. Subjects. Ten volunteers without known pathology or impairment participated in this study. Methods. Root-mean-square (RMS) values were calculated for the DCF, SCM, and AS muscles during performance of the CCF test. Myoelectric signals were recorded from the DCF muscles using bipolar electrodes placed over the posterior oropharyngeal wall. Reliability estimates of normalized RMS values were obtained by evaluating intraclass correlation coefficients and the normalized standard error of the mean (SEM). Results. A linear relationship was evident between the amplitude of DCF muscle activity and the incremental stages of the CCF test (F=239.04, df=36, P<.0001). Normalized SEMs in the range 6.7% to 10.3% were obtained for the normalized RMS values for the DCF muscles, providing evidence of reliability for these variables. Discussion and Conclusion. This approach for obtaining a direct measure of the DCF muscles, which differs from those previously used, may be useful for the examination of these muscles in future electromyographic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of recommendations for SEMG sensors and sensor placement procedures
Hermens, H. J., Freriks, B., Disselhorst-Klug, C., & Rau, G. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00027-4 · Cited by 7,213
Cited by
Falla, D. L., Jull, G. A., & Hodges, P. W. (2004) · Spine · doi:10.1097/01.brs.0000141170.89317.0e · Cited by 617
Self-citationClinical Assessment of the Deep Cervical Flexor Muscles: The Craniocervical Flexion Test
Jull, G. A., O'Leary, S. P., & Falla, D. L. (2008) · Journal of Manipulative and Physiological Therapeutics · doi:10.1016/j.jmpt.2008.08.003 · Cited by 485
Self-citationImpairment in the cervical flexors: a comparison of whiplash and insidious onset neck pain patients
Jull, G., Kristjansson, E., & Dall’Alba, P. (2004) · Manual Therapy · doi:10.1016/s1356-689x(03)00086-9 · Cited by 452
Self-citationEffect of Neck Exercise on Sitting Posture in Patients With Chronic Neck Pain
Falla, D., Jull, G., Russell, T., Vicenzino, B., & Hodges, P. (2007) · Physical Therapy · doi:10.2522/ptj.20060009 · Cited by 391
Self-citationSensorimotor Function and Dizziness in Neck Pain: Implications for Assessment and Management
Kristjansson, E., & Treleaven, J. (2009) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2009.2834 · Cited by 383
Metadata
- Authors
- Falla, D., Jull, G., Dall'Alba, P., Rainoldi, A., & Merletti, R.
- Venue
- Physical Therapy
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-10-01
- Volume
- 83
- Issue
- 10
- Pages
- 899-906
- ISSN
- 0031-9023 (ISSN-L)
- 1538-6724
- OpenAlex
- W2107228219
- Cited by
- 206
- References
- 1
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.