The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Similarities and differences between augmentation index and pulse wave velocity in the assessment of arterial stiffness
Abstract
We investigated whether there was a correlation between the simultaneous assessments of augmentation index (AI) and pulse wave velocity (PWV), undertaken by the SphygmoCor system, and what were the principal factors responsible for differences in these two putative assessments of arterial stiffness, in 105 offspring (41 men, 64 women) aged 19-71 years, of patients with familial hypertension. Arterial stiffness was measured using the SphygmoCor pulse wave analysis system. AI and PWV correlated significantly and positively (r = 0.29, p < 0.005) and the strength of the correlation was greater when each gender was examined separately. This led us to observe several-fold higher AI in women (22.04 +/- 12) than in men (8.59 +/- 13) (p < 0.001); the difference could be explained only in part by an inverse regression correlation between AI and height (r = -0.45; p < 0.001), but not PWV. AI was also more influenced than PWV by heart rate and blood pressure. AI is strongly correlated with a previously validated estimate of arterial stiffness, PWV. It is probable that separate normal ranges should be established for men and women, while further studies determine what parameters other than height are responsible for the gender difference.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chen, C.-H., Nevo, E., Fetics, B., Pak, P. H., Yin, F. C. P., Maughan, W. L., & Kass, D. A. (1997) · Circulation · doi:10.1161/01.cir.95.7.1827 · Cited by 1,307
Cited by
Expert consensus document on arterial stiffness: methodological issues and clinical applications
Laurent, S., Cockcroft, J., Van Bortel, L., Boutouyrie, P., Giannattasio, C., Hayoz, D., Pannier, B., Vlachopoulos, C., Wilkinson, I., Struijker-Boudier, H., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl254 · Cited by 6,077
Ashor, A. W., Lara, J., Siervo, M., Celis-Morales, C., & Mathers, J. C. (2014) · PLoS ONE · doi:10.1371/journal.pone.0110034 · Cited by 452
Augmentation index is associated with cardiovascular risk
Nürnberger, J., Keflioglu-Scheiber, A., Opazo Saez, A. M., Wenzel, R. R., Philipp, T., & Schäfers, R. F. (2002) · Journal of Hypertension · doi:10.1097/00004872-200212000-00020 · Cited by 440
Heart Rate: An Important Confounder of Pulse Wave Velocity Assessment
Lantelme, P., Mestre, C., Lievre, M., Gressard, A., & Milon, H. (2002) · Hypertension · doi:10.1161/01.hyp.0000019132.41066.95 · Cited by 354
Methods and devices for measuring arterial compliance in humans
Pannier, B. M., Avolio, A. P., Hoeks, A., Mancia, G., & Takazawa, K. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(02)02962-x · Cited by 343
Metadata
- Authors
- Yasmin
- Venue
- QJM
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-10-01
- Volume
- 92
- Issue
- 10
- Pages
- 595-600
- ISSN
- 0033-5622 (ISSN-L)
- 1460-2393
- OpenAlex
- W2064080571
- Cited by
- 242
- References
- 1
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Similarities and differences between augmentation index and pulse wave velocity in the assessment of arterial stiffness. https://app.cochat.ai/papers/10.1093/qjmed/92.10.595
- The paper
- Yasmin. (1999). Similarities and differences between augmentation index and pulse wave velocity in the assessment of arterial stiffness. QJM. https://doi.org/10.1093/qjmed/92.10.595
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.