Performance-based methods for measuring the physical function of patients with osteoarthritis of the hip or knee: a systematic review of measurement properties
The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To systematically review the measurement properties (i.e. internal consistency, reproducibility, validity, responsiveness and interpretability) of all performance-based methods which have been used to measure the physical function of patients with osteoarthritis of the hip or knee. METHODS: A systematic search was conducted in Medline, CINAHL, PsychINFO and Embase. Standardized criteria were applied to assess the quality of the clinimetric studies and the measurement properties. RESULTS: Twenty-six performance-based methods were included: 13 walking tests, two stair-climb tests, one chair test and ten multi-item tests. Three out of seven multi-activity tests were tested for internal consistency and two were rated positively. Fourteen tests were tested for reliability and five were rated positively. The absolute measurement error (agreement) was assessed for 10 tests. Only one test received a positive rating. Fourteen tests were tested for construct validity. Only two tests received positive ratings. Responsiveness was assessed for 12 tests, but none of them received a positive rating. A lot of indeterminate ratings were given, mostly for small studies or non-optimal analyses. CONCLUSION: Many more well-designed studies are needed to assess the measurement properties of performance-based methods. More importantly, however, before one can make a justified choice of a particular performance-based method, consensus is needed on what activities should be included in a performance-based test for patients with hip or knee osteoarthritis and which aspects of function should be measured.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Practical Statistics for Medical Research.
Walter, S. D., & Altman, D. G. (1992) · Biometrics · doi:10.2307/2532320 · Cited by 11,668 · cited 1×
“For all measurement properties a sample size of at least 50 patients was considered necessary to receive a positive rating [11].”
BackgroundPractical Statistics for Medical Research
Altman, D. G. (1990) · doi:10.1201/9780429258589 · Cited by 10,668
Norman, G. R., Sloan, J. A., & Wyrwich, K. W. (2003) · Medical Care · doi:10.1097/01.mlr.0000062554.74615.4c · Cited by 4,700 · cited 9×
“Alpha Study size Reliability Design Time interval Study size Absolute measurement error Study size MID SDC MID or 0.5 S.D. Walking tests Self-paced walk 1 [3] NA ICC¼ 0.83 Intra-rater 6 weeks 10 SEM¼ 1.5 10 –”
BackgroundInfluentialAssessment of Quality-of-Life Outcomes
Testa, M. A., & Simonson, D. C. (1996) · New England Journal of Medicine · doi:10.1056/nejm199603283341306 · Cited by 2,551 · cited 1×
“Responsiveness refers to an instrument’s ability to detect important change over time in the concept being measured [20, 21].”
BackgroundThe 6-minute walk: a new measure of exercise capacity in patients with chronic heart failure.
Guyatt, G. H., Sullivan, M. J., Thompson, P. J., Fallen, E. L., Pugsley, S. O., Taylor, D. W., & Berman, L. (1985) · Europe PMC (PubMed Central) · Cited by 2,439
Individual-patient monitoring in clinical practice: are available health status surveys adequate?
McHorney, C. A., & Tarlov, A. R. (1995) · Quality of Life Research · doi:10.1007/bf01593882 · Cited by 2,206 · cited 1×
“Floor and ceiling effects were considered present if more than 15% of respondents achieved the highest or lowest possible score, respectively [19].”
BackgroundBalance in elderly patients: the "get-up and go" test.
Mathias, S., Nayak, U. S., & Isaacs, B. (1986) · PubMed · Cited by 1,543
Deyo, R. A., Diehr, P., & Patrick, D. L. (1991) · Controlled Clinical Trials · doi:10.1016/s0197-2456(05)80019-4 · Cited by 1,364
Bellamy, N., Kirwan, J., Boers, M., Brooks, P., Strand, V., Tugwell, P., Altman, R. D., Brandt, K. D., Dougados, M., & Lequesne, M. G. (1997) · PubMed · Cited by 745
Terwee, C. B., Dekker, F. W., Wiersinga, W. M., Prummel, M. F., & Bossuyt, P. M. M. (2003) · Quality of Life Research · doi:10.1023/a:1023499322593 · Cited by 664 · cited 2×
“It should be considered an aspect of validity in a longitudinal setting [21, 22].”
BackgroundSelf-citationEvaluating quality-of-life and health status instruments: development of scientific review criteria
Lohr, K. N., Aaronson, N. K., Alonso, J., Audrey Burnam, M., Patrick, D. L., Perrin, E. B., & Roberts, J. S. (1996) · Clinical Therapeutics · doi:10.1016/s0149-2918(96)80054-3 · Cited by 591
Vet, H. C. W. D., Adèr, H. J., Terwee, C. B., & Pouwer, F. (2005) · Quality of Life Research · doi:10.1007/s11136-004-5742-3 · Cited by 302 · cited 1×
“Factor analysis should have been applied to determine if scores to be summarized measure the same concept [18].”
MethodSelf-citationResponsiveness to change: an aspect of validity, not a separate dimension
Hays, R. D., & Hadorn, D. (1992) · Quality of Life Research · doi:10.1007/bf00435438 · Cited by 280 · cited 1×
“It should be considered an aspect of validity in a longitudinal setting [21, 22].”
BackgroundAssessing performance-related disability in patients with knee osteoarthritis
Rejeski, W. J., Ettinger, W. H., Schumaker, S., James, P., Burns, R., & Elam, J. T. (1995) · Osteoarthritis and Cartilage · doi:10.1016/s1063-4584(05)80050-0 · Cited by 250
Average patient walking activity approaches 2 million cycles per year
Silva, M., Shepherd, E. F., Jackson, W. O., Dorey, F. J., & Schmalzried, T. P. (2002) · The Journal of Arthroplasty · doi:10.1054/arth.2002.32699 · Cited by 220
Birrell, F., Johnell, O., & Silman, A. (1999) · Annals of the Rheumatic Diseases · doi:10.1136/ard.58.9.569 · Cited by 203 · cited 1×
“Studies in patients undergoing hip or knee replacement (with or without a further specification of the patient population) were also included because in general the majority of these patients are diagnosed with OA [7].”
BackgroundTests for physical function of the elderly with knee and hip osteoarthritis
Lin, Y., Davey, R. C., & Cochrane, T. (2001) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1034/j.1600-0838.2001.110505.x · Cited by 196 · cited 10×
“Nine tests received an indeterminate rating for reliability, six times due to a small sample size (self-paced walk 1, 2 and 3, footprint analysis, Marks’s test, and FAS) and three times due to an inadequate method or unclear description of the design (Lin’s test, PAR and Steultjens’ test).”
BackgroundInfluentialParent, E., & Moffet, H. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.27337 · Cited by 194
Shields, R. K., Enloe, L. J., Evans, R. E., Smith, K. B., & Steckel, S. D. (1995) · Physical Therapy · doi:10.1093/ptj/75.3.169 · Cited by 178 · cited 4×
“86 3 months 148 ILAS [44] No – – K1⁄4 0.”
BackgroundMethodInfluentialAminian, K., Rezakhanlou, K., De Andres, E., Fritsch, C., Leyvraz, P. F., & Robert, P. (1999) · Medical & Biological Engineering & Computing · doi:10.1007/bf02513368 · Cited by 165 · cited 8×
“Description of the performance-based methods Performance-based method Target population Study population Measurement concept Number of activities Activities Functional measures Number of scores Time to administer Requirements Walking tests Self-paced walk 1 Knee OA Knee OA, women [3] Walking time 1 3m walking Time 1 –…”
BackgroundMethodInfluentialStratford, P. W., Kennedy, D. M., Pagura, S. M. C., & Gollish, J. D. (2003) · Arthritis Care & Research · doi:10.1002/art.11196 · Cited by 164 · cited 1×
“In addition, time alone may be inadequate to represent the concept of physical function [24].”
BackgroundReliability of Gait Measurements in People With Osteoarthritis of the Knee
Fransen, M., Crosbie, J., & Edmonds, J. P. (1997) · Physical Therapy · doi:10.1093/ptj/77.9.944 · Cited by 163 · cited 4×
“68 No Accelerometry [34] NA – – – – – – – – Locométrix [35] NA – – – – – – – – Gait analysis 1 [30] NA – – – – – – – – Gait analysis 2 [36] NA ICC1⁄4 0.”
MethodInfluentialGet up and go test in patients with knee osteoarthritis
Piva, S. R., Fitzgerald, G. K., Irrgang, J. J., Bouzubar, F. F., & Starz, T. W. (2004) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2003.05.001 · Cited by 160 · cited 5×
“Get up and go Elderly [39] Knee OA [4] Physical function 1 Chair-rise with 50 ft (17m) walking Time 1 11 s Standard-height chair with 20m corridor, stopwatch Multi-activity tests Madsen Knee OA Knee OA, listed for TKR [40] Disability 2 50m walking 30-step stair climb Time Time (up and down) 2 – 50m space, stair”
MethodInfluentialWhat Is the Best Way of Assessing Outcome After Total Knee Replacement?
Kreibich, D. N., Vaz, M. D., Bourne, R. B., Rorabeck, C. H., Kim, P. R., Hardie, R., Kramer, J. F., & Kirkley, A. (1996) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199610000-00031 · Cited by 144 · cited 9×
“Walking tests Self-paced walk 1 [3] NA ? ? 0 0 NA 0 0 Self-paced walk 2 [25] NA ? 0 0 0 NA 0 0 Self-paced walk 3 [26] NA ? ? 0 ? NA 0 0 Five-minute walking field test [28] NA þ 0 0 ? NA 0 0 Six-minute [2, 30] gait test NA 0 0 0 0 NA ? ? Pedometer [32] NA 0 0 0 ? NA 0 0 Footprint analysis [33] NA ? ? 0 ? NA 0 0 Acceler…”
BackgroundMethodInfluentialMethodological considerations in functional assessment.
Bombardier, C., & Tugwell, P. (1987) · PubMed · Cited by 99
Validation of a simple mechanical accelerometer (pedometer) for the estimation of walking activity
Bassey, E. J., Dallosso, H. M., Fentem, P. H., Irving, J. M., & Patrick, J. M. (1987) · European Journal of Applied Physiology · doi:10.1007/bf00690900 · Cited by 91 · cited 1×
“Walking tests Self-paced walk 1 Knee OA Knee OA, women [3] Walking time 1 3m walking Time 1 – 3m indoor level ground, stopwatch Self-paced walk 2 Knee OA Knee OA, women [25] Walking speed 1 13m walking Gait velocity 1 – 13m walkway, stopwatch Self-paced walk 3 Knee OA Knee-OA, women [26] Knee function 1 13m walking Ti…”
MethodComparative responsiveness of measures of pain and function after total hip replacement
Nilsdotter, A.-K., Roos, E. M., Westerlund, J. P., Roos, H. P., & Lohmander, L. S. (2001) · Arthritis & Rheumatism · doi:10.1002/1529-0131(200106)45:3<258::aid-art258>3.0.co;2-l · Cited by 82 · cited 14×
“Nine tests received an indeterminate rating for reliability, six times due to a small sample size (self-paced walk 1, 2 and 3, footprint analysis, Marks’s test, and FAS) and three times due to an inadequate method or unclear description of the design (Lin’s test, PAR and Steultjens’ test).”
BackgroundInfluentialWalker, D. J. (2002) · British journal of rheumatology · doi:10.1093/rheumatology/41.7.755 · Cited by 69 · cited 2×
“Numact monitor General population [48] Knee OA [49, 50] Spontaneous ambulatory activity 4 Sitting, standing, lying, walking Time, number of steps, average amplitude of steps, longest continuous walk, peak 5-min energy, energy expenditure 6 24 h Numact monitor, data recorder, PC, software”
MethodAssessing Smallest Detectable Change Over Time in Continuous Structural Outcome Measures
Ravaud, P., Giraudeau, B., Auleley, G.-R., Edouard-Noël, R., Dougados, M., & Chastang, C. (1999) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(99)00109-2 · Cited by 68 · cited 6×
“Alpha Study size Reliability Design Time interval Study size Absolute measurement error Study size MID SDC MID or 0.5 S.D. Walking tests Self-paced walk 1 [3] NA ICC¼ 0.83 Intra-rater 6 weeks 10 SEM¼ 1.5 10 –”
BackgroundInfluentialMcCarthy, C. J. (2004) · Rheumatology · doi:10.1093/rheumatology/keh081 · Cited by 65 · cited 3×
“Multi-activity tests Madsen [40] No – – No – – – – Marks [41] No – – No – – – – ALF [42] No r1⁄4 0.”
MethodObserver Reliability and Agreement
de Vet, H. C. W. (2005) · Wiley eBooks · doi:10.1002/0470011815.b2a04033 · Cited by 62
Accelerometric gait analysis for use in hospital outpatients.
Auvinet, B., Chaleil, D., & Barrey, É. (1999) · PubMed · Cited by 51
Reliability and validity of self‐paced walking time measures for knee osteoarthritis
Marks, R. (1994) · Arthritis & Rheumatism · doi:10.1002/art.1790070111 · Cited by 45 · cited 3×
“Walking tests Self-paced walk 1 Knee OA Knee OA, women [3] Walking time 1 3m walking Time 1 – 3m indoor level ground, stopwatch Self-paced walk 2 Knee OA Knee OA, women [25] Walking speed 1 13m walking Gait velocity 1 – 13m walkway, stopwatch Self-paced walk 3 Knee OA Knee-OA, women [26] Knee function 1 13m walking Ti…”
MethodValidity and Reliability of a New Assessment of Lower-Extremity Dysfunction
Öberg, U., Öberg, B. E., & Öberg, T. (1994) · Physical Therapy · doi:10.1093/ptj/74.9.861 · Cited by 36
A continuous patient activity monitor: validation and relation to disability
Walker, D., Heslop, P., Plummer, C., Essex, T., & Chandler, S. (1997) · Physiological Measurement · doi:10.1088/0967-3334/18/1/003 · Cited by 32 · cited 1×
“Numact monitor General population [48] Knee OA [49, 50] Spontaneous ambulatory activity 4 Sitting, standing, lying, walking Time, number of steps, average amplitude of steps, longest continuous walk, peak 5-min energy, energy expenditure 6 24 h Numact monitor, data recorder, PC, software”
MethodSteultjens, M. P. M., Dekker, J., van Baar, M. E., Oostendorp, R. A. B., & Bijlsma, J. W. J. (1999) · Arthritis & Rheumatism · doi:10.1002/1529-0131(199902)12:1<19::aid-art4>3.0.co;2-v · Cited by 28 · cited 4×
“4m space, three-step stair, bed, trained observers Steultjens Hip/knee OA Hip/knee OA [5, 45] Disability in mobility 5 1min walking Sit down in chair Lie down on bench Bend and lift 2 kg 5m walk Guarding while walking (0–2) Rigidity while bending, reclining, sitting down (0–5) Stand-to-sit time Stand-to-recline time 5…”
BackgroundMethodInfluentialSelf-citationPsychometric evaluation of self-report questionnaires: the development of a checklist.
Bot, S. D. M., Terwee, C. B., van der Windt, D., Bouter, L. M., Dekker, J., & de Vet, H. C. W. (2003) · Digital Academic REpository of VU University Amsterdam (Vrije Universiteit Amsterdam) · Cited by 27
Self-citationFive‐minute walking test of aerobic fitness for people with arthritis
Price, L. G., Hewett, J. E., Kay, D. R., & Minor, M. A. (1988) · Arthritis & Rheumatism · doi:10.1002/art.1790010108 · Cited by 26 · cited 2×
“Walking tests Self-paced walk 1 Knee OA Knee OA, women [3] Walking time 1 3m walking Time 1 – 3m indoor level ground, stopwatch Self-paced walk 2 Knee OA Knee OA, women [25] Walking speed 1 13m walking Gait velocity 1 – 13m walkway, stopwatch Self-paced walk 3 Knee OA Knee-OA, women [26] Knee function 1 13m walking Ti…”
MethodMadsen, O. R., & Brot, C. (1996) · Clinical Rheumatology · doi:10.1007/bf02230333 · Cited by 22 · cited 14×
“Description of the performance-based methods Performance-based method Target population Study population Measurement concept Number of activities Activities Functional measures Number of scores Time to administer Requirements Walking tests Self-paced walk 1 Knee OA Knee OA, women [3] Walking time 1 3m walking Time 1 –…”
MethodInfluentialPéloquin, L., Gauthier, P., Bravo, G., Lacombe, G., & Billiard, J.-S. (1998) · Journal of Aging and Physical Activity · doi:10.1123/japa.6.1.36 · Cited by 17
A simple method to measure gait for use in arthritis clinical research
Falconer, J., & Hayes, P. W. (1991) · Arthritis & Rheumatism · doi:10.1002/art.1790040110 · Cited by 15 · cited 3×
“Walking tests Self-paced walk 1 [3] NA ? ? 0 0 NA 0 0 Self-paced walk 2 [25] NA ? 0 0 0 NA 0 0 Self-paced walk 3 [26] NA ? ? 0 ? NA 0 0 Five-minute walking field test [28] NA þ 0 0 ? NA 0 0 Six-minute [2, 30] gait test NA 0 0 0 0 NA ? ? Pedometer [32] NA 0 0 0 ? NA 0 0 Footprint analysis [33] NA ? ? 0 ? NA 0 0 Acceler…”
Odding, E., Valkenburg, H. A., Stam, H. J., & Hofman, A. (2000) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(00)90139-4 · Cited by 15
Spontaneous ambulatory activity as a quantifiable outcome measure for rheumatoid arthritis
Walker, D., Kidd, E., Heslop, P., & Chandler, C. (1999) · Lara D. Veeken · doi:10.1093/rheumatology/38.12.1234 · Cited by 11 · cited 3×
“Numact monitor General population [48] Knee OA [49, 50] Spontaneous ambulatory activity 4 Sitting, standing, lying, walking Time, number of steps, average amplitude of steps, longest continuous walk, peak 5-min energy, energy expenditure 6 24 h Numact monitor, data recorder, PC, software”
MethodLohr, K. N., Aaronson, N. K., Alonso, J., Burnam, A., Patrick, D. L., Perrin, E. B., & Roberts, J. (1996) · Clinical Therapeutics · doi:10.1016/s0149-2918(96)80126-3 · Cited by 6
Walking time measures for evaluating OA of the knee
Marks, R. (2019) · South African Journal of Physiotherapy · doi:10.4102/sajp.v50i1.678 · Cited by 4
Cited by
Dobson, F., Hinman, R. S., Roos, E. M., Abbott, J. H., Stratford, P., Davis, A. M., Buchbinder, R., Snyder-Mackler, L., Henrotin, Y., Thumboo, J., et al. (2013) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2013.05.002 · Cited by 908
EULAR evidence-based recommendations for the diagnosis of knee osteoarthritis
Zhang, W., Doherty, M., Peat, G., Bierma-Zeinstra, M. A., Arden, N. K., Bresnihan, B., Herrero-Beaumont, G., Kirschner, S., Leeb, B. F., Lohmander, L. S., et al. (2010) · Annals of the Rheumatic Diseases · doi:10.1136/ard.2009.113100 · Cited by 753
Bennell, K., Dobson, F., & Hinman, R. (2011) · Arthritis Care & Research · doi:10.1002/acr.20538 · Cited by 463
Walton, M. K., Powers, J. H., Hobart, J., Patrick, D., Marquis, P., Vamvakas, S., Isaac, M., Molsen, E., Cano, S., & Burke, L. B. (2015) · Value in Health · doi:10.1016/j.jval.2015.08.006 · Cited by 307
Dobson, F., Hinman, R. S., Hall, M., Terwee, C. B., Roos, E. M., & Bennell, K. L. (2012) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2012.08.015 · Cited by 278
Self-citation
Metadata
- Authors
- Terwee, C. B., Mokkink, L. B., Steultjens, M. P. M., & Dekker, J.
- Venue
- Rheumatology
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-02-03
- Volume
- 45
- Issue
- 7
- Pages
- 890-902
- ISSN
- 1462-0324 (ISSN-L)
- 1462-0332
- OpenAlex
- W2108524343
- Cited by
- 164
- References
- 46
- FWCI
- 0.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.