The establishment of computed tomography diagnostic reference levels in Portugal
Open accessThe DOI matches its Crossref record.
Abstract
The aims of this study were to investigate the frequency of Portuguese computed tomography (CT) examinations, identify protocol application and establish diagnostic reference levels (DRLs). CT departments (n=211) were surveyed nationally (June 2011-January 2012) and CT protocol information and dose data were collected, as were retrospective age-categorised paediatric CT data from three national paediatric centres. The proposed national CT DRLs (CTDIvol) for adults were 75, 18, 14, 18, 17, 36, 22, 27 and 16 mGy for head, neck, chest, abdomen, pelvis, cervical, dorsal, lumbar and joints, respectively. The levels for paediatric head and chest examinations were as follows: 48 and 2 mGy (newborns), 50 and 6 mGy (5 y olds), 70 and 6 mGy (10 y olds) and 72 and 7 mGy (15 y olds). A limited number of current paediatric protocols aligned to recommended international age categorisations. Portuguese DRLs were generally higher than European recommendations, suggesting potential for optimisation. The need for greater standardisation of age-categorised paediatric protocols was identified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ekpo, E. U., Adejoh, T., Akwo, J. D., Emeka, O. C., Modu, A. A., Abba, M., Adesina, K. A., Omiyi, D. O., & Chiegwu, U. H. (2018) · Journal of Radiological Protection · doi:10.1088/1361-6498/aaaaf8 · Cited by 61
Effective radiation doses of CT examinations in Japan: a nationwide questionnaire-based study
Matsunaga, Y., Kawaguchi, A., Kobayashi, K., Kobayashi, M., Asada, Y., Minami, K., Suzuki, S., & Chida, K. (2016) · The British Journal of Radiology · doi:10.1259/bjr.20150671 · Cited by 29
Radaideh, K., Al-Radaideh, A., Ramli, R. M., Saleh, A., & Alshayeb, R. (2023) · Polish Journal of Medical Physics and Engineering · doi:10.2478/pjmpe-2023-0003 · Cited by 16
Age-specific DRLs for pediatric brain CT: A review for exploring the practices in Saudi Arabia
Aljuaid, L. M., Althobaiti, S. F., Althobaiti, A. A., Alsufyani, A. H., Alotaibi, M. H., Elkhader, B. A., Osman, H., Althoibe, M. M., Raafat, B. M., Dahlawi, H. A., et al. (2025) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2025.111664 · Cited by 6
Garba, I., & Engel-Hills, P. (2025) · Radiography · doi:10.1016/j.radi.2024.09.058 · Cited by 4
Metadata
- Authors
- Santos, J., Foley, S., Paulo, G., McEntee, M. F., & Rainford, L.
- Venue
- Radiation Protection Dosimetry
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-09-15
- Volume
- 158
- Issue
- 3
- Pages
- 307-317
- ISSN
- 0144-8420 (ISSN-L)
- 1742-3406
- OpenAlex
- W2151277804
- Cited by
- 64
- References
- 0
- FWCI
- 2.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The establishment of computed tomography diagnostic reference levels in Portugal. https://app.cochat.ai/papers/10.1093/rpd/nct226
- The paper
- Santos, J., Foley, S., Paulo, G., McEntee, M. F., & Rainford, L. (2014). The establishment of computed tomography diagnostic reference levels in Portugal. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/nct226
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.