THE APPLICATION OF DIAGNOSTIC REFERENCE LEVELS FOR OPTIMISATION OF X-RAY IMAGING IN THE UK
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The concept of diagnostic reference levels (DRLs) has been introduced to provide standard doses against which hospital patient dose measurements can be compared to evaluate practices. DRLs are defined in terms of measured dose quantities. National DRLs can be derived from surveys of patient doses for common types of examinations in 20-30 large hospitals. The International Commission on Radiological Protection proposes that median doses for each type of examination at every hospital be collated and DRLs based on the third quartile value of the distribution. Once DRLs have been set, periodic audits of patient dose should be undertaken for examinations that reflect the clinical workload. Median doses from these distributions should be compared with relevant DRLs to identify procedures for which further optimisation is required and appropriate corrective action taken. This paper discusses factors that should be considered in the optimisation process and gives examples of experiences in application of DRLs in Scotland.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Although advisory, these Diagnostic Reference Levels (DRLs) facilitate quality assurance in accordance with the UK’s Ionising Radiation (Medical Exposure) Regulations (IR(ME)R), which require regular assessment and adjustment of protocols.111”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [111]
Citations
Cites
Hart, D. B., Mc, H., & Bf, W. (2007) · Europe PMC (PubMed Central) · Cited by 156
Radiation dosimetry for diagnostic medical exposures
Martin, C. J. (2007) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncm495 · Cited by 61
Self-citationJärvinen, H., Seuri, R., Kortesniemi, M., Lajunen, A., Hallinen, E., Savikurki-Heikkilä, P., Laarne, P., Perhomaa, M., & Tyrväinen, E. (2015) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncv044 · Cited by 56
Practical Radiation Protection in Healthcare
Orton, C. G. (2003) · Medical Physics · doi:10.1118/1.1569272 · Cited by 46
Management of patient dose in radiology in the UK
Martin, C. J. (2011) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncr386 · Cited by 46
Self-citationSookpeng, S., Martin, C. J., Gentle, D. J., & López-Gonzalez, M. R. (2013) · Journal of Radiological Protection · doi:10.1088/0952-4746/34/1/103 · Cited by 34
Self-citationSookpeng, S., Martin, C. J., & Gentle, D. J. (2014) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncu236 · Cited by 23
Self-citation
Cited by
Setting up computed tomography automatic tube current modulation systems
Martin, C. J., & Sookpeng, S. (2016) · Journal of Radiological Protection · doi:10.1088/0952-4746/36/3/r74 · Cited by 69
Self-citationSimeonov, F., Palov, N., Ivanova, D., Kostova-Lefterova, D. Z., Georgiev, E., Zagórska, A., Madzharova, R., & Vassileva, J. (2017) · Physica Medica · doi:10.1016/j.ejmp.2017.04.025 · Cited by 6
CT dose reduction: approaches, strategies and results from a province-wide program in Quebec
Nassiri, M. A., Rouleau, M., & Després, P. (2016) · Journal of Radiological Protection · doi:10.1088/0952-4746/36/2/346 · Cited by 6
“DRLs should be used as indicators to identify ways of further optimization [29], but many centers misinterpret DRLs as a regulatory limit that should not be exceeded [17, 23].”
Almén, A., & Båth, M. (2015) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncv512 · Cited by 3
Ngankem, A. E., Shouop, C. J. G., Bongué, D., Zamo, F. C. D., Simo, C. R. T., Samba, O. N., & Moyo, M. N. (2026) · Radiological Physics and Technology · doi:10.1007/s12194-026-01089-z · Cited by 1
“For dosimetric optimization purposes, the third quartiles of ESD distributions obtained from the NMME ESD model and PHITS simulation were compared with published diagnostic reference levels (DRLs) from national [13, 36–39] and international [40–46] studies.”
Metadata
- Authors
- Martin, C. J.
- Affiliations
- University of Glasgow (GB)
- Corresponding author
- Martin, Colin J.
- ORCID
- Martin, Colin J.
- Venue
- Radiation Protection Dosimetry
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-11-19
- Volume
- 169
- Issue
- 1-4
- Pages
- 211-216
- ISSN
- 0144-8420 (ISSN-L)
- 1742-3406
- OpenAlex
- W2377728353
- Cited by
- 8
- References
- 7
- Citations by year
- 2026: 2 · 2022: 1 · 2019: 1 · 2017: 1 · 2016: 2 · 2015: 1
- FWCI
- 1.08
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Radiation Protection Dosimetry (publishedVersion)
- PubMed (publishedVersion)
- HighWire Press Open Archive (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
- Keywords
- diagnostic reference levels, radiography, dose survey, ICRP recommendations, radiation protection, Scotland
- MeSH terms
- Data Collection, United Kingdom, Hospitals, Humans, Radiation Dosage, Radiation Protection, Radiography, Dental, Radiology, Reference Values, Retrospective Studies, Scotland, Tomography, X-Ray Computed, X-Rays, Workload
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: THE APPLICATION OF DIAGNOSTIC REFERENCE LEVELS FOR OPTIMISATION OF X-RAY IMAGING IN THE UK. https://app.cochat.ai/papers/10.1093/rpd/ncv433
- The paper
- Martin, C. J. (2016). THE APPLICATION OF DIAGNOSTIC REFERENCE LEVELS FOR OPTIMISATION OF X-RAY IMAGING IN THE UK. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncv433
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.