Identifying Sleep Apnea from Self-Reports
The DOI matches its Crossref record.
Abstract
An apnea score (AS) was developed as a potential screening tool for sleep apnea. This was based on self-report questionnaire responses of 76 sleep disorder center patients and 20 sleep survey volunteers. Twenty volunteers and 23 patients (group I) comprised the initial AS development group. Their questionnaire responses were compared to polysomnographic apnea indexes (AI) and apnea plus hypopnea indexes (AHI). Stepwise multivariate discriminant analysis was used to test whether or not selected group I questionnaire responses could be used to correctly classify respondents into apnea (AI or AHI greater than 5) or nonapnea (AI, AHI less than or equal to 5) groups. Self-reports of "stops breathing during sleep," "loud snoring," and history of adenoidectomy best discriminated normal (AI less than or equal to 5) from apnea (AI greater than 5) cases. The AS derived from group I responses to these three variables was then computed for group II (n = 53). After examination of the AS results, the AS was modified to include just "stops breathing" and "loud snoring" and the AI criterion was raised to 10 per hour. This revised AS correctly identified 100% of the cases with moderate-severe sleep apnea (AI or AHI greater than 40) and 70-76% of all sleep apnea cases with AI or AHI greater than 5. Predictive accuracy was 88% for AI greater than 10. The two questions that comprise the AS should be incorporated into risk appraisal instruments or interviews to screen for sleep apnea.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Using the Berlin Questionnaire To Identify Patients at Risk for the Sleep Apnea Syndrome
Netzer, N. C., Stoohs, R. A., Netzer, C. M., Clark, K., & Strohl, K. P. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-131-7-199910050-00002 · Cited by 2,973
STOP Questionnaire: A Tool to Screen Patients for Obstructive Sleep Apnea
Chung, F., Yegneswaran, B., Liao, P., Chung, S. A., Vairavanathan, S., Islam, S., Khajehdehi, A., & Shapiro, C. M. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816d83e4 · Cited by 2,355
A systematic review of screening questionnaires for obstructive sleep apnea
Abrishami, A., Khajehdehi, A., & Chung, F. (2010) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-010-9280-x · Cited by 581
Pulmonary Complications of Obesity
Koenig, S. M. (2001) · The American Journal of the Medical Sciences · doi:10.1097/00000441-200104000-00006 · Cited by 530
Qaseem, A., Dallas, P., Owens, D. K., Starkey, M., Holty, J.-E. C., Shekelle, P., & for the Clinical Guidelines Committee of the American College of Physicians* (2014) · Annals of Internal Medicine · doi:10.7326/m12-3187 · Cited by 516
Metadata
- Authors
- Kapuniai, L. E., Andrew, D. J., Crowell, D. H., & Pearce, J. W.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 1988-09
- Volume
- 11
- Issue
- 5
- Pages
- 430-436
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W1630610588
- Cited by
- 145
- References
- 0
- FWCI
- 1.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Identifying Sleep Apnea from Self-Reports. https://app.cochat.ai/papers/10.1093/sleep/11.5.430
- The paper
- Kapuniai, L. E., Andrew, D. J., Crowell, D. H., & Pearce, J. W. (1988). Identifying Sleep Apnea from Self-Reports. Sleep. https://doi.org/10.1093/sleep/11.5.430
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.