Evaluation of EEG Cyclic Alternating Pattern during Sleep in Insomniacs and Controls under Placebo and Acute Treatment with Zolpidem
The DOI matches its Crossref record.
Abstract
In nonrapid eye movement (NREM) sleep, electroencephalographic cyclic alternating patterns (CAPS) express the organized complexity of arousal-related phasic events. As a translation of sustained instability of the arousal level, CAPS increase under perturbation and decrease under sleep-promoting conditions. After adaptation to the sleep lab, 18 subjects (12 with persistent psychophysiological insomnia and 6 without sleep complaints), all aged 40-60 years, underwent a random sequence of two nonconsecutive nocturnal recordings, one under placebo and one under an imidazopyridine hypnotic agent (zolpidem). The choice of this drug was oriented by its capability to warrant, at the selected dose of 10 mg, a physiological profile of sleep. Polysomnographic parameters and self-report of sleep quality by means of visual analogue scale (VAS) were assessed by analysis of variance followed by a Scheffé test when F statistics were significant. The placebo nights of controls showed a significantly longer duration of total sleep time (+60 minutes) compared with the placebo nights of insomniacs. However, no relevant differences emerged from the other traditional polysomnographic variables. Conversely, CAP rate (CAP time x 100/NREM sleep time) showed highly sensitive and consistent modifications. Under placebo, CAP rate was significantly higher among insomniacs compared with controls (62.2% vs. 38.5%). Under medication, CAP rate dropped to 26.8% in insomniacs, whereas it was only moderately reduced in controls (31%). CAP rate values paralleled the self-rating estimation of sleep quality, but the VAS means differed significantly only among insomniacs where a sharp average fall from 45 mm (placebo nights) to 15 mm (zolpidem nights) could be detected. Our findings suggest that CAP rate in sleep analysis can represent a useful tool for the diagnosis of insomnia and for gaining insight into the therapeutic efficacy of hypnotic-sedative drugs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Harvey, A. G. (2002) · Behaviour Research and Therapy · doi:10.1016/s0005-7967(01)00061-4 · Cited by 1,790
Edinger, J. D., Bonnet, M. H., Bootzin, R. R., Doghramji, K., Dorsey, C. M., Espie, C. A., Jamieson, A. O., McCall, W. V., Morin, C. M., & Stepanski, E. J. (2004) · Sleep · doi:10.1093/sleep/27.8.1567 · Cited by 1,039
Krystal, A. D., & Edinger, J. D. (2008) · Sleep Medicine · doi:10.1016/s1389-9457(08)70011-x · Cited by 590
The nature of arousal in sleep
Halász, P., Terzano, M., Parrino, L., & Bódizs, R. (2004) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2004.00388.x · Cited by 529
Self-citationCyclic alternating pattern (CAP): The marker of sleep instability
Parrino, L., Ferri, R., Bruni, O., & Terzano, M. G. (2012) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2011.02.003 · Cited by 442
Self-citation
Metadata
- Authors
- Giovanni Terzano, M., & Parrino, L.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-01
- Volume
- 15
- Issue
- 1
- Pages
- 64-70
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W2409765593
- Cited by
- 80
- References
- 0
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of EEG Cyclic Alternating Pattern during Sleep in Insomniacs and Controls under Placebo and Acute Treatment with Zolpidem. https://app.cochat.ai/papers/10.1093/sleep/15.1.64
- The paper
- Giovanni Terzano, M., & Parrino, L. (1992). Evaluation of EEG Cyclic Alternating Pattern during Sleep in Insomniacs and Controls under Placebo and Acute Treatment with Zolpidem. Sleep. https://doi.org/10.1093/sleep/15.1.64
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.