Beta (20–28 Hz) and Delta (0.3–3 Hz) EEGs Oscillate Reciprocally Across NREM and REM Sleep
The DOI matches its Crossref record.
Abstract
Across-night oscillations of beta (20-28 Hz) and delta (0.3-3 Hz) electroencephalograms (EEGs) were examined with spectral analysis in 10 normal young adult subjects (Ss). In each S, power densities of beta were found to oscillate reciprocally with delta power density across both nonrapid eye movement (NREM) and rapid eye movement (REM) sleep. Linear correlation coefficients between log power density of delta vs. beta were significant (p less than 0.0001) for each S. An incidental observation was that beta power within REM was reliably lower in epochs with more eye movement activity. The reciprocal relationship between beta and delta holds implications for sleep physiology and supplements our earlier finding that sigma (12-15 Hz) oscillates reciprocally with delta within NREM sleep. These descriptions of the continuously varying EEG across sleep provide information not available when EEG measures are tabulated by discrete NREM periods and REM periods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
All‐night dynamics of the human sleep EEG
AESCHBACH, D., & BORBÉLY, A. A. (1993) · Journal of Sleep Research · doi:10.1111/j.1365-2869.1993.tb00065.x · Cited by 299
Maloney, K. J., Cape, E. G., Gotman, J., & Jones, B. E. (1997) · Neuroscience · doi:10.1016/s0306-4522(96)00298-9 · Cited by 259
Effects of diazepam and zolpidem on EEG beta frequencies are behavior-specific in rats
van Lier, H., Drinkenburg, W. H. I. M., van Eeten, Y. J. W., & Coenen, A. M. L. (2004) · Neuropharmacology · doi:10.1016/j.neuropharm.2004.03.017 · Cited by 164
High frequency EEG activity during sleep: Characteristics in schizophrenia and depression
Tekell, J. L., Hoffmann, R., Hendrickse, W., Greene, R. W., Rush, A. J., & Armitage, R. (2005) · Clinical EEG and Neuroscience · doi:10.1177/155005940503600107 · Cited by 94
Chapotot, F., Buguet, A., Gronfier, C., & Brandenberger, G. (2001) · Neuroendocrinology · doi:10.1159/000054648 · Cited by 72
EEG spectral activity during paradoxical sleep: further evidence for cognitive processing
Jouny, C., Chapotot, F., & Merica, H. (2000) · Neuroreport · doi:10.1097/00001756-200011270-00016 · Cited by 42
Lucid dreaming occurs in activated rapid eye movement sleep, not a mixture of sleep and wakefulness
Baird, B., Tononi, G., & LaBerge, S. (2022) · Sleep · doi:10.1093/sleep/zsab294 · Cited by 41
Thalamic oscillations distinguish natural states of consciousness in humans
Chowdhury, A., Wu, X., Beilner, T., Schreiner, T., Koeglsperger, T., Mehrkens, J.-H., Remi, J., Vollmar, C., Kaufmann, E., & Staudigl, T. (2026) · Nature Human Behaviour · doi:10.1038/s41562-026-02446-z · Cited by 1
“…bear interesting resemblances to 40-Hz oscillations detected in magnetoencephalography during REM sleep 46 , beta-band power enhancements 47 and oscillatory activity in REM sleep 48,49 , beta bursts during wake 50 , and narrowband EEG oscillations at 25–35 Hz in children and young…”
Metadata
- Authors
- Uchida, S., Maloney, T., & Feinberg, I.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-07
- Volume
- 15
- Issue
- 4
- Pages
- 352-358
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W2291888110
- Cited by
- 92
- References
- 0
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.