CoChat

Computerized Adjustable Versus Fixed NCPAP Treatment of Obstructive Sleep Apnea

Scharf, Martin B., Brannen, Donald E., McDannold, Michael D., Berkowitz, David V. · 1996 · Sleep
Cited by 50

The DOI matches its Crossref record.

Abstract

An automated positive airway pressure device that monitors respiratory patterns and provides dynamic, real-time, relational pressure has been developed for the treatment of obstructive sleep apnea (OSA). The purpose of this study was to compare self-adjusting pressure to classical nasal continuous positive airway pressure (NCPAP). Subjects were newly diagnosed patients with a minimum respiratory disturbance index (RDI) of 15 episodes per hour who had undergone NCPAP titration and been using classical NCPAP at home on a nightly basis for at least 2 weeks. Patients then underwent repeat standard polysomnographic (PSG) evaluations for 2 nights using a self-adjusting pressure mode and a standard NCPAP mode randomly assigned in a single-blind crossover fashion. Eight males and four females (n = 12), aged 48.4 +/- 12.2 years [mean +/- and standard deviation (SD)], completed the study. During initial diagnostic PSG, the RDI was 57.3 +/- 30.8 episodes per hour. The RDI and minimum oxygen saturation for both treatment nights were significantly improved from those of the diagnostic PSGs (p < 0.001). The subjects spent 63.1 +/- 34.2% of total sleep time below prescribed pressure while on automatic pressure Percent of total sleep time in stage 3/4 sleep was significantly higher during self-adjusting pressure, at 8.6 +/- 7.5%, compared to standard NCPAP, at 4.6 +/- 6.0% (p < 0.05). Computerized adjustable nasal positive airway pressure effectively controls OSA, fluidly providing the minimal pressure necessary to control respiratory events without causing sleep disruption.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/sleep/19.6.491

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 50

Metadata

Authors
Scharf, M. B., Brannen, D. E., McDannold, M. D., & Berkowitz, D. V.
Venue
Sleep
Published
1996-08
Volume
19
Issue
6
Pages
491-496
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W2402835470
Cited by
50
References
0
FWCI
2.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Computerized Adjustable Versus Fixed NCPAP Treatment of Obstructive Sleep Apnea. https://app.cochat.ai/papers/10.1093/sleep/19.6.491
The paper
Scharf, M. B., Brannen, D. E., McDannold, M. D., & Berkowitz, D. V. (1996). Computerized Adjustable Versus Fixed NCPAP Treatment of Obstructive Sleep Apnea. Sleep. https://doi.org/10.1093/sleep/19.6.491

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.